1.     Press TIMER button to set the operating hours you desired (1 to 24 hours, the sign of timer 
      will light on). When the set time has been reached, the machine will turn off automatically. 
      The display window will show the hour(s) you set as you press TIMER button. If the timer 
      button is not pressed, the unit will work continuously.

2.     By pressing the timer but without turning on the other functions, you can PRE-SET the time 
      for the machine to work.  For example, if you press the timer to '2', the unit will work 
      utomatically after 2 hours.

Sleep function
1.     In cooling mode, by pressing the SLEEP button, the set temperature will increase 1oC at the 
      1st hour, another 1 oC at the second hour, then keeps at that temperature.
2.     In sleep mode, the ventilation will keep at low speed. Re-press the SLEEP button, the setting 
      temperature and ventilation speed will return to the pre-selected one.
3.     The unit will shut down automatically after the SLEEP function running for 12 hours.
4.     Please note, the sleep function is not available while the machine is working in ventilation, 
      dehumidification or auto mode.  Only available in Cooling or Heating mode.
5.     When the machine is in Sleep function, the Fan Speed would turn to be LOW speed.

Dehumidify (DRY) mode

In dehumidify (DRY) mode, the temperature cannot be adjusted, the ventilation will fix at low speed.   
When the unit is operating in Dehumidify ( DRY) mode, humidity extracted from the air is collected in an 
internal tank.  If the tank reaches full, the compressor and motor cut out automatically.  At the same time, 
the “Water Full” indicator comes on.  An alarm will also sound.  When the tank is full, drain the water as 
shown in the page concerning “DRAINAGE”.    You may also use the unit without having to empty the tank 
so often by using “continuous drainage”, please also refer to the page about “DRAINAGE”.

Self-diagnosis
This machine is equipped with self-diagnosis function.  If the LED will show the word “E1”:  

 

E1 means the sensor wire for room temperature does not connect well (this wire is located 
in the center of the evaporator).

As this time, please call your service centre.  Please DO NOT dismantle the machine by 
yourselves in any case.

All the above functions can also be performed with 
the supplied remote control.

This remote control requires 2 pcs AAA batteries to 
operate (battery is not supplied along with the unit).

FIG.19

Setting timer

Summary of Contents for 187-5320

Page 1: ...rspro com User Manual RS PRO Local Air Conditioner Stock number 187 5320 EN DE ...

Page 2: ...1500 mm Net Weight 31 kg Dimension WxDxH 415 x 418 x 790 mm REMARK 1 Measuring condition for above is as per EN 14511 Cooling œDB 35o C WB 24o C DB temperature of dry bulb room temperature WB temperature of wet bulb relative humidity 2 Test condition for data in our rating label is as per safety regulation EN60335 2 40 3 Current Fuse F10AL250V or T10AL250V 4 The data marked with may vary for techn...

Page 3: ...it in swimming pools washrooms or similar wet areas Leave the unit to stand for 12hours before connecting to the mains supply after transport or when it has been titled ex During cleaning Only use the unit in the upright position on a flat level surface even during transport and at least 50cm from any objects Do not use the unit in a potentially explosive environment containing combustible liquids...

Page 4: ... supervision Switch off and unplug the unit when not in use Never leave a functioning device unsupervised Do not pull the unit along by the cord Avoid over twisting coiling pulling the power cord never use nylon or iron wire to tide the power cord Make sure that the plug and socket remain visible and accessible at all the time Do not use extension cords Never reach to retrieve the unit if it has f...

Page 5: ...WED TO DISMANTLE OR MODIFY THE APPLIANCE THE MACHINE IS TO BE USED ONLY FOR ITS PRESCRIBED PURPOSE ANY OTHER USE IS DEEMED TO BE A CASE OF MISUSE THE USER OPERATOR NOT THE MANUFACTUER WILL BE LIABLE FOR ANY DAMAGE OR INJURIES OF ANY KIND CAUSED AS A RESULT OF THIS Safety relating to refrigerant R290 Read these warnings carefully This appliance contains the refrigerant R290 R290 is a refrigerant th...

Page 6: ...ea where the room size corresponds to the room area as specified for operation Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry accredited assessment authority which authorises their competence to handle refrigerants safely in accordance with an industry recognised assessment specification Servicing shall only...

Page 7: ...lter air inlet 12 Air filter air inlet Accessories 13 Inward Adaptor connecting unit Exhaust Pipe 14 Exhaust hose 15 Flat Type adaptor Inserting over hose and into window spacer or into hole in the wall window 16 PVC Window kit A for filling the open window space 17 PVC Window kit B for filling the open window space 18 PVC Window kit C for filling the open window space and with hole for connection...

Page 8: ...need Feed exhaust hose through the window spacer and slide window across so that spacer is held securely This technique may also be used for sash windows Note Take care to maintain protection against intruders 2 Using the connector FIG 9 Cut a 160mm diameter hole in the wall or window Feed exhaust hose through the window or wall and attach the threaded adaptor from the outside as shown Extendable ...

Page 9: ...o build up causing the unit to overheat and shut down The hose may be extended from 300mm to 1500mm but for maximum efficiency use the shortest length possible WARNING The length of the exhaust pipe is specially designed according to the specification of this product Do not replace or prolong it with your own private hose as this could cause the unit to mal function FIG 10 FIG 11 FIG 12 FIG 13 ...

Page 10: ...is variable and depends on the ambient conditions where the unit is used The filter should be checked periodically and replaced if necessary normally it s 6 months below is the installation of the active carbon filter along with this unit FIG 14 1 Remove the filter frame from the unit 2 Separate the filter fixer from the filter frame 3 Remove the active carbon filter from its plastic bag 4 Insert the...

Page 11: ...AY window H TEMPERATURE UP button I TEMPERATURE DOWN button 1 Timer indicator 2 High fan speed indicator 3 Medium fan speed indicator 4 Low fan speed indicator 5 AUTO mode indicator 6 COOL mode indicator 7 FAN mode indicator 8 DEHUMIDIFY DRY mode indicator 9 Water full indicator 10 Compressor operation indicator 11 Ionizer TiO2 mode indicator only for the model with ionizer TiO2 function 12 Sleep ...

Page 12: ...de the unit can cool ventilate or heat depending on ambient temperature and setpoint adjustment The unit is preset as follows 1 If ambient temperature is 23 C the unit will be in automatic cooling mode Default setting 24 C During this operation the indicator for AUTO and COOL mode light up in green 2 If the ambient temperature is 24 C but 20 C the unit will work in ventialtion mode During this ope...

Page 13: ... comes on Setting temperature 1 Press Temperature up or Temperature down button to regulate the temperature you desired 2 The display window will show the temperature you set as you press Temperature up or Temperature down button Otherwise it will always show the ambient temperature 3 The pre setting temperature of this machine is 24oC for cooling Setting ventilation speed Press SPEED button to ch...

Page 14: ...ion or auto mode Only available in Cooling or Heating mode 5 When the machine is in Sleep function the Fan Speed would turn to be LOW speed Dehumidify DRY mode In dehumidify DRY mode the temperature cannot be adjusted the ventilation will fix at low speed When the unit is operating in Dehumidify DRY mode humidity extracted from the air is collected in an internal tank If the tank reaches full the c...

Page 15: ...ater level of the see through window beneath the water gate 2 In case the water full indicator is in red please drain the water from the drain point at the back side of the unit until the red light goes out The unit should work again now IMPORTANT 1 To prolong the compressor s life after switch off of the unit please wait for 3 minutes at least before re switch 2 The cooling system will switch off i...

Page 16: ...er tray 5 Repeat until the unit is emptied 6 Replace the rubber plug and tighten the drain knob firmly 7 Switch on the unit the full water or compressor operating indicator should not be flashing FIG 21 Should you prefer to use the appliance without having to empty the tank every so often p roceed as follows Remove the drain knob and rubber plug and retain for future use Connect the drain tube suppl...

Page 17: ...e cabinet Cleaning the filter Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt from the filters and then rinse thoroughly under running water no hotter than 40oC Dry thoroughly before replacing Notice Never operate the unit without the filters End of season storage Drain any water in the unit before completely operating the unit on ventilation only mode for a few hours to t...

Page 18: ...thing in the room producing lots of heat The machine seems to do nothing Is the filter dusty contaminated Is the air intake or output blocked up Is the room temperature below your selected temperature Toonoisy Is the machine positioned unevenly so as to create vibration Is the floor underneath the machine uneven The compressor doesn t run Is so it is possible the overheat protection of the compresso...

Page 19: ...tes entsprechen der EN 14511 DB 35 C WB 24 C DB Trockentemperatur Raumtemperatur WB Feuchttemperatur relative Feuchte 2 Die Testbedingungen für die Angaben inunserem Typenschild entsprechen der Sicherheitsvorschrift EN 60335 2 40 3 Strom und Sicherung F10AL250V oder T10AL250V ...

Page 20: ...20 rspro com ...

Page 21: ...21 rspro com ...

Page 22: ...22 rspro com ...

Page 23: ...ern sie überwacht werden bzw in den sicheren Umgang mit dem Gerät eingewiesen wurden und die damit verbundenen Gefahren verstehen Kinder sollten mit dem Gerät nicht spielen Kinder dürfen das Gerät nur unter Beaufsichtigung reinigen und warten ELEKTRISCHE SICHERHEIT Nur zum Gebrauch in geschlossenen Räumen Bei Nichtbenutzung ausschalten und vom Netz trennen Das Klimagerät nicht in einer Feuchtzelle...

Page 24: ... reinigen Die Temperatur und Ventilationseinstellungen senken sobald im Raum die gewünschten Bedingungen erzielt sind C Aufbau 1 Bedienungsfeld Display 2 Fernbedienungsempfänger 3 Entlüftung 4 Traggriff 5 Wasserabfuhr zum Energiesparen 6 Durchsichtiges Fenster zur Wasserstandkontrolle im Gerät 7 Luftfilter Lufteintritt 8 Netzkabelfach 9 Abluftaustritt 10 Ablaufanschluss 11 Luftfilter Lufteintritt ...

Page 25: ...andhalter oder in die Öffnung in der Wand im Fenster 15 Adapterdeckel 16 Ablaufschlauch zur kontinuierlichen Entleerung 17 Aktivkohlefilter 18 Fernbedienung D Installation des Gerätes Das Gerät lässt sich durch die vormontierten Rollen von Raum zu Raum verschieben 1 Mit ausziehbarem Abluftschlauch Abb 7 Abb 8 ...

Page 26: ...topfen Nur den mitgelieferten Schlauch verwenden und den Abluftschlauch und den Geräteadapter an der Rückseite des Klimagerätes anheften Knicks und Biegungen im Abluftschlauch vermeiden weil sie zu einer Verdichtung der ausgestossenen Feuchtluft führen könnten was eine Überhitzung und das Ausschalten des Gerätes zur Folge hat der Schlauch kann von 300 mm bis zu 1500 mm verlängert werden aber für m...

Page 27: ...Betriebsstörungen verursachen Einbau des Kohlefilters 1 Den Filterrahmen aus dem Gerät ziehen 2 Das Filterfixierband vom Filterrahmen trennen 3 Den Aktivkohlefilter aus dem Plastiksack nehmen 4 Den Aktivkohlefilter in den Filterrahmen einlegen 5 Den Filter befestigen indem das Fixierband wieder an den Filterrahmen geklebt wird 6 Den Filterrahmen wieder einsetzen Abb 14 Abb 16 ...

Page 28: ... DOWN Taste 1 Anzeige Zeitschaltuhr 2 Anzeige hohe Ventilatorgeschwindigkeit 3 Anzeige mittlere Ventilatorgeschwindigkeit 4 Anzeige niedrige Ventilatorgeschwindigkeit 5 Anzeige AUTO Modus 6 Anzeige COOL Modus 7 Anzeige FAN Modus 8 Anzeige DEHUMIDIFY DRY Modus 9 Anzeige HEATING Modus 10 Anzeige Wasser voll 11 Anzeige Verdichter Modus 12 Anzeige Ionisator TiO2 Modus 13 Anzeige Schlummermodus Abb 17 ...

Page 29: ...dus kühlt oder lüftet das Gerät Dies ist abhängig von der Umgebungstemperatur und dem Einstellwert Standard Einstellung im Automatik Modus Wenn die Umgebungstemperatur im Auto Betrieb über 23 C liegt kühlt das Gerät bis zum Einstellwert Werkseinstellung 24 C Während dieses Vorgangs leuchtet die LED Anzeige grün Wenn die Umgebungstemperatur kleiner oder gleich ist als 25 C stellt das Gerät automati...

Page 30: ... des aktivierten Modus leuchtet dann auf Temperatur einstellen 1 Taste Temp Temp drücken um die gewünschte Temperatur einzustellen 2 Während der Regelung wird der Temperaturwert auf dem Display angezeigt Ansonsten wird an dieser Stelle die Temperatur der Umgebung gezeigt 1 Voreinstellung der Temperatur 24 C für Kühlung Lüftung einstellen Taste SPEED drücken um eine von drei Leistungsstufen der Lüf...

Page 31: ...smodus arbeitet die Lüftung mit der niedrigen Leistung Nach dem erneuten Drücken der Taste SLEEP werden die zuvor eingestellten Temperaturwerte und Leistungsstufen wieder erzielt 4 Bleibt der Bereitschaftsmodus länger als 12 Stunden aktiv schaltet das Gerät automatisch ab 5 Die SLEEP Funktion ist nicht verfügbar wenn das Gerät im Lüftungs Entfeuchtungs oder im automatischen Modus arbeitet Diese Fu...

Page 32: ...iO2 Funktion Der Ionisator kann Staub und grosse Partikeln in die Luft blasen TiO2 Fotokatalysator kann die Vermehrung von Bakterien hemmen Beide Funktionen dienen der Verbesserung der Luftqualität Um sie freizuschalten die ION TiO2 Taste drücken Das erneute Drücken der ION TiO2 Taste schaltet sie aus Selbstdiagnose Das Gerät ist mit einer Selbstdiagnose Funktion ausgestattet Sollten Betriebsstöru...

Page 33: ...len von Wasser nach einer Stunde Betrieb zu steigern wobei die Wassermenge NICHT 2 5 l überschreiten darf Ansonsten leuchtet die Anzeige Wasser voll rot auf und das Gerät hört auf zu arbeiten Damit der Alarm Tank voll ausgelöst werden kann darf diese Massnahme nur im eingeschalteten Zustand vorgenommen werden Auch auf den Wasserstand im durchsichtigen Fenster unterhalb der Wasserschleuse achten 2 ...

Page 34: ... Heizung manchmal kurz zum Stillstand um den Frost abtauen zu lassen Sollte das eintreten abwarten bis die Heizung wieder ihren Betrieb aufnimmt F Entleerung Wenn das Gerät im Kühl oder Entfeuchtungsmodus DRY läuft wird die aus der Luft aufgenommene Feuchtigkeit im internen Tank gesammelt Wenn der Tank voll ist schalten sich der Verdichter und der Motor automatisch ab Gleichzeitig erscheint die An...

Page 35: ...ch mittels eines Verlängerungsschlauch und eines entsprechenden Anschlusses verlängern Hinweis 1 Der Abfluss muss tiefer liegen als das Abflussloch am Gerät 2 In diesem Entleerungsmodus funktioniert die blinkende Anzeige Wasser voll nicht 3 Zur Verlängerung des Ablaufschlauchs kann ein zweiter Schlauch angeschlossen werden Aussendurchmesser 18 mm Das Verlängerungsstück ist im Lieferungumfang nicht e...

Page 36: ...aximieren das Klimagerät regelmässig reinigen Gehäuse reinigen Das Gehäuse mit einem weichen feuchten Tuch reinigen Niemals aggressive Chemikalien Benzin Waschmittel chemische behandelte Tücher bzw sonstige Reinigungsmittel verwenden Filter reinigen Losen Staub und Schmutz vom Filter mit dem Staubsauger oder durch leichtes Klopfen auf das Filter entfernen oder unter laufendem Wasser das nicht heis...

Page 37: ...im Raum Erzeugt etwas im Raum viel Energie Das Gerät scheint nichts zu schaffen Ist das Filter verstaubt oder verschmutzt Ist der Lufteintritt oder austritt verstopft Unterschreitet die Raumtemperatur den eingestellten Sollwert Zu viel Lärm Ist das Gerät so uneben positioniert dass es vibriert Ist der Fussboden unter dem Gerät uneben Der Verdichter läuft nicht Es mag sein dass der Überhitzungsschu...

Reviews: