1
True RMS Thermal MultiMeter / English
19/07/2018 Version No. 001
1-Introduction
Professional True RMS Industrial Digital Multimeter with built-in Thermal Imager, and TFT color
LCD display, providing fast A/D converting sampling time, high accuracy. It is easy to find and solve
the problems of the production equipments, providing Bluetooth technology. It is much more safe
measurements with double molded plastic housing design and Ip65 waterproof function.
Key features
• 6000 count 2.8'' TFT Color LCD display
• Built-in Thermal imager with Max,Min and Center crosshair targeting
• 50Hz fast Thermal image frame rate
• DC voltage
• AC, AC+DC TRMS Voltage
• DC current
• AC, AC+DC TRMS current
• Resistance and Continuity test
• Diode test
• Capacity
• Frequency
• Duty Cycle
• Temperature with K-type probe
• flexible coils current
This symbol adjacent to another symbol, terminal or operating device indicates that the operator must refer
to an explanation in the Operating Instructions to avoid personal injury or damage to the meter.
WARNING
This
WARNING
symbol indicates a potentially hazardous situation, which if not avoided, could result in
death or serious injury.
CAUTION
This
CAUTION
symbol indicates a potentially hazardous situation, which if not avoided, may result damage
to the product.
This symbol advises the user that the terminal(s) so marked must not connected to a circuit point at which
the voltage with respect to earth ground exceeds (in this case) 1000 VAC or VDC.
This symbol adjacent to one or more terminals identifies them as being associated with ranges that may,
in normal use, be subjected to particularly hazardous voltages. For maximum safety, the meter and its test
leads should not be handled when these terminals are energized.
This symbol indicates that a device is protected throughout by double insulation or reinforced insulation.
2. Safety
2.1.
safety infomation