Specifications
1-1 General Specifications
LCD display :
4000 counts, 3 3/4 digit LCD readout.
Measuring rate :
1.5 times / sec.
Overrange display :
“OL” is displayed for “
Ω
” functions,
Actual value is shown for “A” and “V”
function.
Automatic power off time :
Approximately 30 minutes after power on.
Low battery indicator :
<
is displayed.
Power requirement :
9V battery type 6LR61 (IEC) Alkaline.
Battery life :
ALKALINE 9V ; 200 hours.
1-2 Environmental Conditions
Indoor Use only.
Calibration :
One year calibration cycle.
Operating temperature :
0°C ~ 30°C (
≦
80% RH)
30°C
~
40°C (
≦
75% RH)
40°C
~
50°C (
≦
45%RH)
Storage temperature :
-20 to +60°C, 0 to 80% RH (batteries not
fitted).
Overvoltage category :
IEC 61010-1 600V CAT.
Ⅲ
.
CAT.
Ⅲ
equipment is designed to protect
against the transients in the
equipment in fixed installations, such as
distribution panels, feeders
and short branch circuits and lighting
systems in large buildings.
Operating altitude :
2000m (6562 ft)
Conductor Size :
34mm diameter.
Pollution degree :
2
EMC :
EN 61326-1
Shock vibration :
Sinusoidal vibration per MIL-T-28800E
(5 ~ 55 Hz, 3g maximum).
Summary of Contents for 123-3229
Page 1: ...Instruction Manual ICM 135R Electrical Clamp Multimeter EN FR IT DE ES...
Page 5: ...5 AC V DC V Resistance...
Page 7: ...7 Data Hold 190A 0A Hz ACA 50Hz...
Page 14: ...14...
Page 15: ...Mode d emploi ICM 135R Multim tre pince lectrique FR...
Page 19: ...19 Vc a Vc c R sistance...
Page 21: ...21 Maintien de l affichage 190A 0A Hz ACA 50Hz...
Page 28: ...28...
Page 29: ...Istruzioni d uso ICM 135R Multimetro a pinza que IT...
Page 33: ...33 Vc a Vc c Resistenza...
Page 35: ...35 Memorizzazione dei dati 190A 0A Hz ACA 50Hz...
Page 42: ...42...
Page 43: ...Bedienungsanleitung ICM 135R Strommesszange DE...
Page 47: ...47 AC V DC V Wechsel Gleichspannung Widerstand...
Page 49: ...49 Data Hold Messwertspeicherung 190A 0A Hz ACA 50Hz...
Page 56: ...56...
Page 57: ...57 Instrucciones de uso ICM 135R Mult metro de pinza ES...
Page 61: ...61 V de c a V de c c Resistencia...
Page 63: ...63 Retenci n de datos 190A 0A Hz ACA 50Hz...
Page 70: ...70...
Page 71: ...71...