background image

1

E

ng

lis

h

한글

3332NK0

V7 Plus Series

V712+ OPERATING INSTRUCTIONS

Make sure that the delivered unit conforms to your requirement, and also check for any missing or damaged parts. 

Before using this V712+, be sure to read this OPERATING INSTRUCTIONS thoroughly to ensure proper operation. 

 

[Accessories]  V712+ OPERATING INSTRUCTIONS: 1 copy,   Fixtures: 4 pcs 

 

[Models]

Notes on Safe Usage

In this "V712+ OPERATING INSTRUCTIONS", you will 

nd various notes categorized under the following two levels with the 

signal words "Danger"  and "Caution."

Indicates an imminently hazardous situation which, if not avoided, will result in death or serious 

injury.
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate 

injury and could cause property damage.

Even some items indicated 

 may also result in a serious accident.

  Never use the output function of AnyTouch for operations that may threaten human life or to damage the system, 

such as switches to be used in case of emergency.  Please design the system so that it can cope with malfunction of 

a touch switch.  A malfunction of the touch switch will result in machine accident or damage.

  Turn off the power supply when you set up the unit, connect cables or perform maintenance and inspection.  

Otherwise, electrical shock or damage may occur.

  Never touch any terminals while the power is on.  Otherwise, electric shock may occur.

  You must put a cover on the terminals on the unit when you turn the power on and operate the unit.  Without the 

terminal cover in place, an electric shock may occur.

  The liquid crystal in the LCD panel is a hazardous substance.  If the LCD panel is damaged, never swallow the leaked 

liquid crystal.  If the liquid crystal spills on your skin or clothing, use soap and wash off thoroughly.

  For AnyTouch using a lithium battery, never disassemble, recharge, deform by pressure, short-circuit, nor reverse the 

polarity of the battery, and never dispose of the battery in 

re.  Failure to follow these conditions will lead to explosion 

or ignition.

  For AnyTouch using a lithium battery, never use a battery that is deformed, leaks, or shows any other signs of 

abnormality.  Failure to follow these conditions will lead to explosion or ignition.

  Check the appearance of the unit when it is unpacked.  Do not use the unit if any  damage or deformation is found.  

Failure to do so may lead to 

re, damage or malfunction.

  For use in a facility or for a system related to nuclear energy, aerospace, medical, traf

c equipment, or mobile 

installations, please consult your local distributor.

  Operate (or store) AnyTouch under the conditions indicated in this manual and related manuals.  Failure to do so 

could cause 

re, malfunction, physical damage or deterioration.

  Understand the following environmental limits for use and storage of AnyTouch.  Otherwise, 

re or damage to the unit 

may result.

  -  Avoid locations where there is a possibility that water, corrosive gas, 

ammable gas, solvents, grinding 

uids or 

cutting oil can come into contact with the unit.

  -  Avoid high temperature, high humidity, and outside weather conditions, such as wind, rain or direct sunlight.

  -  Avoid locations where excessive dust, salt, and metallic particles are present.

  -  Avoid installing the unit in a location where vibration or physical shock may be transmitted.

12 inch display

Device type  

 

TFT color LCD (SVGA, 32,768 colors)

Touch switch type 

 

M  : matrix resistance 

lm type 

 (None)  : analog resistance 

lm type

Power supply type 

 

D  : 24V DC (Comply with CE/UL/cUL) 

 (None)  : 100-240V AC

Performance  

 

i  : advanced model 

 (None)  : standard model

Summary of Contents for AnyTouch V7 Plus Series

Page 1: ...iquid crystal If the liquid crystal spills on your skin or clothing use soap and wash off thoroughly For AnyTouch using a lithium battery never disassemble recharge deform by pressure short circuit nor reverse the polarity of the battery and never dispose of the battery in fire Failure to follow these conditions will lead to explosion or ignition For AnyTouch using a lithium battery never use a bat...

Page 2: ... it may cause a malfunction RS Automation Co Ltd is not responsible for any damages resulting from repair overhaul or modification of AnyTouch that was performed by an unauthorized person Do not use a sharp pointed tool when pressing a touch switch Doing so may damage the screen Only experts are authorized to set up the unit connect the cables or perform maintenance and inspection For AnyTouch usin...

Page 3: ... and no conductive dust Mechanical Working Conditions Vibration Resistance Vibration frequency 10 to 150Hz Acceleration 9 8m s2 1 0G Half amplitude 0 075mm 3 directions of X Y and Z one hour Shock Resistance Pulse shape Sine half wave Peak acceleration 147m s2 15G 3 directions of X Y and Z 6 times Electrical Working Conditions Noise Resistance Noise voltage 1500Vp p noise width 1 s Rise time 1ns S...

Page 4: ...CN1 is used for communicating between a PLC and a V7 RS 232C RS 422 485 The pin arrangement of serial connector is as follows CN1 Dsub 25pin Female Pin No Signal Contents 1 FG Frame ground 2 SD RS 232C send data 3 RD RS 232C receive data 4 RS RS 232C RS request to send 5 CS RS 232C CS clear to send 6 Not used 7 SG Signal ground 8 Not used 9 5V Use prohibited 10 0V Use prohibited 11 Not used 12 SD ...

Page 5: ...a 2 SD RD RS 485 data 3 5V Output power supply Max 150 mA 4 5V 5 SG Signal ground 6 SG 7 RD RS 232C receive data 8 SD RS 232C send data LAN Connector LAN V712i only This port is used for Ethernet 10BASE T 100BASE TX connection Specification comply with IEEE802 3 UDP IP and TCP IP supported LAN Pin No Signal Contents 1 TX Ethernet send 2 TX Ethernet send 3 RX Ethernet receive 4 NC Not used 5 NC Not ...

Page 6: ...eference Manual Function DIPSW 2 3 and 4 not used Keep OFF DIPSW 5 6 7 8 Setting of Terminal Resistance Set DIPSW 7 ON in the case of connecting V7 to PLC by RS 422 485 Two wire system Set DIPSW 5 1 7 ON in the case of connecting V7 to PLC by RS 422 485 Four wire system Set DIPSW 6 or DIPSW 8 when using MJ1 or MJ2 with the following connection Master station of Multi Link2 Temperature control netw...

Page 7: ...able Power Supply Cable Connection Connect the power suppy cable to the terminal on the backside of the unit When connecting the power supply cable tighten the terminal screw to the following torque Screw Size Torque Clamp Terminal Unit mm M4 0 5N m 7 9MAX 7 0MAX The power source must be within the allowable voltage fluctuation Use a power source with low noise between the cables or between the gro...

Page 8: ...t off 2 Slide the battery holder cover in the direction of the arrow as shown in the illustration below to open it 3 Check that the battery is securely attached to the backside of the cover and connect the battery connector 4 Close the battery holder cover 5 Enter a date five years from now for Battery replacement on the sticker on the battery holder 6 Turn on the power to the V7 unit and check tha...

Page 9: ...로 단자에 접촉하지 마십시오 감전의 우려가 있습니다 통전 운전을 실시하는 경우에는 반드시 단자커버를 장착해 주십시오 단자커버를 장착하지 않으면 감전의 우려가 있습 니다 액정패널의 액체 액정 는 유해물질입니다 액정패널이 파손된 경우 유출된 액정을 입에 넣지 마십시오 피부나 의복에 묻은 경우에는 비누 등으로 씻어내 주십시오 리튬전지를 사용한 AnyTouch 를 사용하는 경우 전지의 역접속 충전 분해 가압변형 불속에 투입 단락은 하지 마 십시오 파열 발화의 우려가 있습니다 리튬전지를 사용한 AnyTouch 를 사용하는 경우 전지변형 액누출 기타 이상을 발견하였을 때는 사용하지 마십시오 파열 발화의 우려가 있습니다 V7 Plus 시리즈 V712 사용설명서 이번에는 후지 프로그래머블 조작표시기 AnyTouch V71...

Page 10: ...지해 주십시오 감전 화재의 원 인이 됩니다 AnyTouch 내에 도전선 이물질이 들어가지 않도록 주의해 주십시오 화재 고장 오작동의 원인이 됩니다 배선 종료후에는 AnyTouch 의 먼지방지지를 제거하고 운전해 주십시오 먼지방지지를 부착한 채로 운전하면 화재 고장 오작동 고장의 원인이 됩니다 AnyTouch 의 수리ㆍ분해ㆍ개조는 현장에서는 절대로 실시하지 말고 당사 또는 당사 지정업자에게 수리를 의뢰해 주십 시오 고장의 원인이 됩니다 AnyTouch 의 수리ㆍ분해ㆍ개조를 당사 이외 또는 당사 지정 이외의 제3자가 실시한 경우 그것이 원인으로 발생한 손 해 등에 대해서는 책임을 지지 않으므로 양지하여 주십시오 끝이 예리한 물건으로 터치패널을 누르지 마십시오 설치 배선작업 및 보수ㆍ점검은 전문지식이 있는 사람이...

Page 11: ... 이하 단 결로가 없을 것 내용제성 절삭유 유기용제 부착이 없을 것 사용분위기 내식성 가스가 없고 먼지가 심하지 않을 것 도전성 먼지가 없을 것 기 계 적 가 동 조 건 내진동 진동주파수 10 150Hz 가속도 9 8m s2 1 0G 편진폭 0 075mm X Y Z 3방향 각1시간 내충격 펄스파형 정현반파피크 가속도 147m s2 15G X Y Z 3방향 각6회 전 기 적 가 동 조 건 내노이즈 1500Vp p 펄스폭 1μs 기동시간 1ns 내정전기방전 IEC61000 4 2에 준거 접촉 6kV 공기중 8kV 설 치 조 건 접지 D종 접지 구조 보호구조 앞면 패널 IP65 준거 방수패킹 사용시 뒷면 패널 IP20 준거 형상 일체형 설치방법 패널매입설치 냉각방식 자연공냉 무게 kg 아날로그 방식 단체 약2 7...

Page 12: ...리얼 커넥터 CN1 커넥터 CN1 는 PLC와의 통신 RS 232C RS 422 485 에 사용합니다 핀 배치는 아래와 같습니다 CN1 Dsub 25pin Female 핀 No 신호명 내용 1 FG 프레임 그라운드 2 SD RS 232C 송신 데이터 3 RD RS 232C 수신 데이터 4 RS RS 232C RS 송신요구 5 CS RS 232C CS 송신가능 6 미사용 7 SG 시그널 그라운드 8 미사용 9 5V 사용불가 10 0V 사용불가 11 미사용 12 SD RS 422 송신 데이터 13 SD RS 422 송신 데이터 14 RS RS 422 RS 송신 데이터 15 미사용 16 미사용 17 RS RS 422 RS 송신 데이터 18 CS RS 422 CS 수신 데이터 19 CS RS 422 CS 수신 데이...

Page 13: ... 7 RD RS 232C 수신 데이터 8 SD RS 232C 송신 데이터 LAN용 커넥터 LAN V712i 에 한함 Ethernet 10BASE T 100BASE TX 에 접속할 때 사용합니다 사양 IEEE802 3 준거 UDP IP 및 TCP IP에 대응 LAN 핀 No 신호명 내용 1 TX Ethernet 송신신호 2 TX Ethernet 송신신호 3 RX Ethernet 수신신호 4 NC 미사용 5 NC 미사용 6 RX Ethernet 수신신호 7 NC 미사용 8 NC 미사용 MJ1 MJ2 및 LAN 커넥터는 모두 8핀 모듈러 잭입니다 명판을 확인하여 오삽입하지 않도록 주의해 주 십시오 설치방법 설치방법 1 판금패널 최대 판후 5mm 에 V7 Plus시리즈를 삽입합니다 판금패널 패널 컷 구멍 설치금구 ...

Page 14: ... 참조해 주십시오 DIPSW2 4 미사용 미사용 OFF로 합니다 DIPSW5 6 7 8 종단저항 설정 CN1에서 PLC와 RS 422 485 2선식 로 접속하는 경우 DIPSW7을 ON합니다 CN1에서 PLC와 RS 422 485 4선식 로 접속하는 경우 DIPSW5 1 7을 ON합니다 MJ1 MJ2 으로 아래의 접속을 하는 경우에 DIPSW6 DIPSW8 을 ON합니다 멀티링크2에서 접속하는 경우의 마스터 RS 485로 온도조절 넷 PLC 2Way 접속하는 경우 카드 레코더 CREC 옵션 을 사용하는 경우 씨리얼 증설 I O V I O 옵션 를 사용하는 경우 RS 485로 V Link 접속하는 경우의 종단에 있는 V7 Plus 시리즈 1 하드웨어 버전 b 부터 지원될 것입니다 하드웨어 버전은 장비의 뒷면 ...

Page 15: ...전원케이블 배선과 접지에 대하여 감전의 우려가 있습니다 전원케이블의 배선은 전원 OFF 상태에서 실시해 주십시오 전원케이블 배선 전원케이블은 본체 배면의 단자에 접속합니다 전원을 배선하는 경우의 단자나사 조이기는 아래 값으로 실시해 주십시오 나사 사이즈 조임토크 압착단자 단위 mm M4 0 5Nm 7 9 MAX 7 0 MAX 전원은 허용전원전압 변동범위내에서 사용해 주십시오 선간 및 대지간 모두 노이즈가 적은 전원을 사용해 주십시오 전원선은 전압강하를 작게 하기 위해 가능한 한 굵은 선을 사용해 주십시오 AC100V선 DC24V선은 고전압 대전류 케이블과 접근되지 않도록 충분히 거리를 떼어 주 십시오 단자대에는 반드시 단자커버를 장착해 주십시오 단자커버를 닫을 때는 오른쪽 그림과 같이 커버끝을 누르면 간단히...

Page 16: ...업은 V7 본체의 전원이 OFF 상태에서 실시해 주십시오 1 본체 전원을 OFF합니다 2 전지홀더의 커버를 방향 위 그림 참조 으로 슬라이드시키면서 엽니다 3 전지가 커버 뒤에 단단히 실장되어 있는지 확인한 후 전지의 커넥터를 장착합니다 4 전지홀더의 커버를 닫습니다 5 전지홀더 씰의 Battery replacement 란에 5년후의 연월일을 기입합니다 6 V7 본체의 전원을 ON으로 하여 전지가 세트되었는지를 본체 의 Main Menu 화면에서 확인합니다 전지가 세트되어 있 지 않은 경우 SRAM Clock 스위치가 점멸하고 왼쪽 아래에 Battery not set 메시지가 표시됩니다 세트되면 SRAM Clock 스위치는 소등되고 메시지는 소멸됩니다 전지의 전압이 저하되었을 때는 Brownout Batte...

Page 17: ......

Page 18: ...Publication AnyTouchV7 IN004A V712 EK November 2010 ...

Page 19: ......

Page 20: ...Copyright 2010 RS Automation Co Ltd All rights reserved ...

Reviews: