background image

Installation of Antenna System DELTA 200 S 
 

Antenna position: 
The  antenna  system  DELTA  200  S  should  be  mounted  at  the  mast-head.  No  other  antennas  should 
be mounted above the antenna system. 
 
Antenna cable: 
For  the  antenna  system  DELTA  200  S  coaxial  cable  with  a  characteristic  impedance  of  50  Ohm  is 
used,  preferably  Aircell-7  or  Belden  H2000  Flex.  A  BNC-plug  is  used  at  both  ends  of  the  antenna 
cable.  ATTENTION!  UHF-connectors  (PL-connectors)  may  NOT  be  used  for  this  antenna 
system! Important: Keep the plug strain-relieved! 
An optional disconnecting point at the mast-heel 
is established with BNC-connectors. Keep the antenna cable to the distribution box AV 205 as short as 
possible. Check the antenna cable for short circuit before connecting it! 
 
Important:  All  metal  parts  of  the  antennas  as  well  as  the  connectors  must  not  have  electrical 
contact  to  other  metal  parts  of  the  ship  because  the  shield  of  the  cable  is  connected  to  the 
negative element of the power supply. 
 
Installation of the distribution box AV 205: 
 
Install the distribution box AV 205 below deck near the instruments connected. 
Connect the antenna cable to the AV 205 terminal „Input: Antenna DELTA 200 S“. 
Connect  the  VHF  radio  telephone  to  terminal  5  „UKW-Funktelefon  (VHF)“.  This  is  the  only  terminal 
with UHF-connector to avoid confusion. Connect the remaining instruments to terminal 1 to 4 of the AV 
205  using BNC-connectors (see AV 205-cover for association). 
None of the instruments connected to this system may be connected to ground. 
 
Power supply: 
 
Important: Do not switch on the power supply before the installation is completed! 
 
Use a switch or cutout of the switch board for the power supply to switch off the antenna system when 
none of the receivers connected is in use. Connect the blue lead of the AV 205 power supply cord to 
the negative element and the brown lead to the positive element of a 12V or 24V power supply. The 
yellow/green  lead  of  the  AV  205  power  supply  cord  has  to  be  connected  to  a  good  ground.  For  the 
operation  of  the  antenna  system  DELTA  200  S  it  is  important  that  the  distribution  box  AV  205  is 
connected  to  the  power  supply  before  (or  as  soon  as)  the  receiver  instruments  connected  to  the  AV 
205 are switched on; else faulty operation may occur (antenna alarm, incorrect calculation of position, 
etc.). The power supply to the antenna system need not be switched on for the operation of the 
VHF marine telephone. 
 
Not  all  receivers  are  able  to  handle  the  antenna  voltage  from  the  DELTA  200S  without  producing 
interference.  Therefore  the  output  level  of  the  corresponding  wideband  output  can  be  reduced  by 
adjusting the associated trimmer potentiometer counter-clockwise until the reception is clear again. 
 

Installation of plug-in modules 
 

Two  plug-in  modules  can  be  inserted  into  the  distribution  box  AV  205.  For  retrofitting  of  plug-in 
modules, open the AV 205 case. The plug-in modules have 2 connection pins on one side and 3 pins 
on the other side. Insert the plug-in module into the sockets of the AV 205 main board with the 3 pin 
end  of  the  module  at  the  output  side  of  the  AV  205.  Then  close  the  AV  205  case  and  identify  the 
association on top of the AV 205 cover using a waterproof marker. 
 
To guarantee a perfect working antenna it is mandatory to do the installation in a workman-like 
manner. 
 
Any faults caused from neglecting these instructions are excluded from the manufacturer's 
warranty. 
 
In case of doubt consult a specialist. 