Doc.:  OM_VIAS & VICD (10D) 

1.4. 

Symbols and Notes 

 
 

 

This symbol points to important references for the proper use of the unit.  

Not paying attention to these references can lead to a working disruption of the unit 
or to the environment!

 

 

This  danger  symbol  means  a  potential  or  direct  threat  to  the  life  and  health  of 
persons and/or a possible dangerous situation.  

Ignoring these references may result in dire consequences for your health and/or can 
lead to property damages!

 

 

This symbol points to operation tips and especially useful information of optimal use. 

 

 

1.5. 

Validity  

 
These operating instructions are valid for the models:   

 

 
VIENNA Closed Display Case “VICD” 
 

- Closed on front for assisted service only 
    
  self-contained  or  remote refrigerated 

 
VIENNA Closed Display Case “VICD” 
 

- Closed on front for assisted service only 
- Service side with pull out drawer 
    
  self-contained  or  remote refrigerated  

 

VIENNA Air Screen Displays “VIAS” 
 

- Open on front for self serve 
 
  self-contained  or  remote refrigerated

 

VIENNA Counter Top Displays 
 

- Closed on front for assisted service only VICD
- Open on front for self-serve VIAS 
 
  self-contained  or  remote refrigerated

  

Summary of Contents for VIENNA Air Screen

Page 1: ...Operating and Maintenance instructions Please read this manual carefully before you start to operate your cooling equipment Following the instructions helps to ensure the unit is fully functional at a...

Page 2: ...of the unit 4 5 Safety notes 4 6 Fundamental operating notes 5 6 1 Switching on the appliance 5 6 2 Setting the temperature 5 6 3 Manual defrosting 5 6 4 Lighting 5 7 Operating description 6 7 1 Load...

Page 3: ...a qualified refrigeration technician Air currents near the refrigerating unit resulting from improperly installed ventilation or draughts are to be avoided in order to ensure the efficient functioning...

Page 4: ...can lead to property damages This symbol points to operation tips and especially useful information of optimal use 1 5 Validity These operating instructions are valid for the models VIENNA Closed Disp...

Page 5: ...those intended are to be considered as not being in compliance with the regulations The manufacturer supplier is not liable for any damages resulting from such actions The user bears the entire risk U...

Page 6: ...refrigerated display case is set at a temperature of 39 F Your desired temperature can be set by holding down the SET button 4 and simultaneously pressing UP button 1 for higher temperatures or DOWN b...

Page 7: ...portant to leave adequate free space for the refrigerated air to circulate within the display case Products should be kept clear of the shaded areas shown in the picture A minimum clearance of 1 shoul...

Page 8: ...the bracket in the new position 4 Choose level slant position Display cases with drawer element Models Gastro L and Gastro SL and series Green L and Green SL are equipped with a drawer which offers ea...

Page 9: ...these parts It is absolutely necessary to bear some fundamental things in mind to keep this stainless steel unit working and to maintain its long life always keep the stainless steel surface clean ma...

Page 10: ...rior have to be cleaned with lukewarm soap water Always dry the interior after cleaning After cleaning lift the evaporator remove the lock and drop the evaporator back in its original position Insert...

Page 11: ...2 in and outside ATTENTION Hold glass during opening and cleaning Don t let the glass top fall down Hold the glass and bring it back in end position Front glasses made of insulated double glass Pictur...

Page 12: ...stomer service The ventilators are not running Customer service The air circulation in the well is blocked Clear the ventilation openings Status display and error notification Message Cause Error elim...

Page 13: ...ediately by a specialized service representative 11 Maintenance In order to guarantee efficient operation of the refrigerated well along with optimum presentation of the goods the entire technological...

Page 14: ...11 2011 Technical changes reserved Page 13 Doc OM_VIAS VICD 10D 12 Wiring diagram Wiring diagram VICD and VIAS self contained 115 V 1 PH 60 Hz Wiring diagram VICD and VIAS remote refrigerated 115 V 1...

Page 15: ...Valid from 11 2011 Technical changes reserved Page 14 Doc OM_VIAS VICD 10D Wiring diagram VICD and VIAS self contained 115 208 230 V 1 PH 60 Hz...

Page 16: ...ng diagram VICD and VIAS self contained 115 V 1 PH 60 Hz With rear ventilation Kit including time relay for longer runtime of the fan Wiring diagram VICD and VIAS self contained 115 208 230 V 1 PH 60...

Page 17: ...P a r t s S e r v i c ed i r e c t 1 8 6 6 7 2 7 0 7 2 1 S e r v i c eE ma i l s e r v i c e r p i i n d u s t r i e s c o m P a r t s E ma i l p a r t s r p i i n d u s t r i e s c o m...