It is important for safe use of the VARIBOX FC to use an EPDM CDS counter 

coupler on an EPDM CDS extractor tube. And on a Aflas/Viton CDS extractor 

pipe, only the Aflas/Viton CDS counter coupler must be used. The difference 

between an EPDM or Aflas/Viton counter coupler is in the colours of both 

counter couplers. The EPDM CDS counter coupler has a red core (dot in the 

middle) and the Aflas/Viton version has a natural (white) core (dot in the 

middle).

The CDS counter coupler can be damaged. For example, the part sliding over 

the CDS extractor tube can be damaged, or the sealing surface may be 

damaged. If so, the CDS counter coupler must be replaced. Besides that, the 

CDS counter coupler can also be damaged due to chemical attack. Therefore, it 

is important to regularly check the CDS counter coupler.

The expected lifetime of the CDS counter coupler is one year. Inspect the CDS 

counter coupler regularly (i.e., annually or earlier if necessary) and replace if 

necessary. The rate of chemical attack is highly dependent on the product, its 

concentration and temperature.

The metal bracket secures the position of the CDS counter coupler on the CDS 

extractor tube. If the metal bracket is not clipped underneath the CDS 

extractor tube, air can enter the system which can lead to faults in the pumping 

system.

 

Make sure that the handle of the CDS counter coupler is inclined upwards. Slide 

the CDS counter coupler completely over the CDS extractor tube. Turn and clip 

the metal bracket underneath the edge of the CDS extractor tube. Push the 

handle of the CDS counter coupler downwards until it clicks in position. The 

CDS extractor pipe is now connected. And the product can be pumped out.  

No, pay attention to overpressure in the VARIBOX FC. There is a risk of leakage 

when disconnecting in case of overpressure. When the VARIBOX FC is under 

internal pressure, the pressure must be released first. This can be done by 

switching on the pump or by opening the screwcap. Make sure to wear 

personal protection.

 

The extractor hose must be flexible to avoid excessive force on the CDS 

counter coupler. It is important that the hose is attached at 180 ° to the handle.

 