Check the hose connections for any
air leaks and tighten if necessary – replace
any worn parts.
With air flowing through the respirator adjust
the air pressure at the point of attachment to
the recommended pressure as specified in
the Breathing Air Pressure Table (page 8).
Connect the EN 14594 (AS/NZS 1716)
approved RPB
®
Air Supply Hose to a
breathing air source supplying EN 12021
(AS/NZS 1715)or better quality air. Connect
the Breathing Air Line quick disconnect
fitting to the coupler on top of the Radex
®
.
Airflow in the apparatus must be above
160lpm and the yellow indicator is not visible
when the flow drops below this rate. DO NOT
use the apparatus when the indicator is not
showing.
FIGURE 2.1
FIGURE 2.2
FIGURE 2.3
RESPIRATOR SETUP AND CARE
CONNECT THE AIR SUPPLY
The NOVA 1
®
Supplied Air Respirator must be
supplied with respirable air meeting the
requirements of EN 12021 and AS/NZS
1715 or higher quality and meeting other
governing body requirements.
WARNING