Change the ROWASHER Microbe Filter Mat EVERY MONTH
To Maintain Cleaning Performance
For Technical Support or to order more consumables
Tel: +44 (0)121 526 8181 www.rozone.co.uk
10.
MAINTENANCE AND CARE
DAILY
Check to see if the red “LOW FLUID” indicator light is flashing
If the red “LOW FLUID” light is flashing, pour 20 litres of ROwash Cleaning Solution
into the ROwasher sink
NOTE – Do not overfill the ROwasher.
If the red “LOW FLUID” indicator light is flashing the heater element in the base unit
will be switched off and the cleaning solution will begin to lose temperature.
Therefore it is important to top up the fluid as soon as possible to keep the microbes
at their optimum working temperature
MONTHLY - Change the Filter Mat
First remove the sink tray
Wring out the fluid from the old Filter Mat into the sink
Please dispose of used Filter Mat according to local authority regulations for waste
containing mineral oil (see “Instructions for Disposal”)
Place new ROwasher Microbe Filter Mat white side up onto the filter support grid
Replace the sink tray
YEARLY - Annual maintenance check on the Rowasher recommended
If a cleanout and change of fluid is required please follow correct procedure
Ensure the machine is switched off and unplugged from the mains
Lift off the sink top and disconnect hose pipes
Remove dirty solution from the base unit and dispose of waste according to local
authority regulations (see “Instructions for Disposal”)
Rinse / jetwash the base unit
Replace sink top checking that the hose pipes are all connected
Remove sink tray
Place new ROwasher Microbe Filter Mat white side up on the filter support grid