6.4 Combustion air
The appliance, during its operation, requires
combustion air.
The inflow of combustion air can be obtained in
the following ways:
• it can come directly from outside with direct
connection to the combustion chamber;
• it can come from the installation room or suita-
ble adjacent rooms.
Extraction of combustion air from outside
In this case, a possible alternative may be:
• to connect the combustion air inlet of the ap-
pliance to the air intake using a special pipe
(
Fig. 13
).
Fig. 13
Extraction of combustion air in the room
Create the air intake on the wall (
Fig. 14 - PA
= Air
Intake), and leave the appliance to withdraw the
room air, making sure to connect the section of
corrugated pipe on the air inlet pipe, if supplied,
fixing it with the strap and folding it slightly
downwards to prevent any resonance effects.
If the rear wall of the appliance is an external wall,
create a hole for the intake of combustion air at
a height of approximately 20-30 cm from the
ground, respecting the dimensional indications
provided in the technical data sheet, paragraph
4.3 Technical characteristics
.
PA
Fig. 14
A non-closable permanent aeration grid must
be placed externally; in areas that are particularly
windy and exposed to weathering, provide rain
and wind protection.
Ensure that the air intake is positioned so that it
won't be accidentally obstructed.
If it is impossible to create an external air intake
in the wall behind the appliance (non-perimeter
wall), a hole must be made in an external wall of
the room where the appliance is positioned.
If it is not possible to create the fresh air intake in
the room, an external hole can be created in an
adjacent room provided it is permanently inter-
connected by means of a transfer grille.
It is forbidden to take combustion air from ga-
rages, warehouses of combustible material or
places with activities at risk of fire.
If there are other heating appliances in the room,
the combustion air inlets must guarantee the
necessary volume of air for the correct operation
of all devices.
If one or more extraction fans (extrac-
tor hoods) are present and operating
in the installation room, combustion
malfunctions may occur due to lack of
combustion air.
Summary of Contents for RONDINE AIR
Page 33: ......
Page 46: ...46 004778620 23 11 2020 4 2 Dimensions 553 527 934 Ø 80 263 252 235 5 Ø 2 5 Fig 5 ...
Page 64: ...64 004778620 23 11 2020 ...
Page 95: ...ITALIANO ENGLISH DEUTSCH FRANÇAIS ESPAÑOL 004778620 23 11 2020 95 ...
Page 108: ...108 004778620 23 11 2020 4 2 Abmessungen 553 527 934 Ø 80 263 252 235 5 Ø 2 5 Abb 5 ...
Page 126: ......
Page 157: ......
Page 158: ......
Page 159: ......