MODEL

RCD-2000

Ambient Temperature

32 ~ 104°F / 0~40°C 

Ambient Humidity

40 ~ 90%

Detection Methods

UV, MG, FL, MP

Power Voltage

110V/60Hz (US, CA) or 220 ~ 240V/50Hz (EU)

Power Consumption

20W

Unit Size

10.80” w x 5.90” d x 5.70” h

Weight

2.20 lbs.

SPECIFICATIONS

6

TROUBLESHOOTING

1. Clean the counterfeit detector regularly, and clean the dust on the ultraviolet bulb with a dry towel 

to maintain ultraviolet light quality.

2. Be certain to switch the power off when finishing detection to ensure long bulb life.

3. Disconnect the power cord for cleaning or maintenance if the unit will not be used for a long time.

SYMPTOM

SOLUTION

Switch is powered on, but 

Ultraviolet bulbs are not working.

Replace with new 5W Ultraviolet bulbs

Switch is powered on, but the 

watermark verification window is 

not lit.

Contact Royal Sovereign Service Center

MAINTENANCE

Summary of Contents for RCD-2000

Page 1: ...Owner s Manual 4 WAY COUNTERFEIT DETECTOR RCD 2000 Royal Sovereign International Inc Please read and retain these instructions To register your product please go to www royalsovereign com...

Page 2: ...th safetyinformation instructions for optimal use and proper care and maintenance for your product Please read this manual carefully before operating CONTENTS SAFETY INSTRUCTIONS BOX CONTENTS PRODUCT...

Page 3: ...rvice repair technician or contact Royal Sovereign 5 Do not use the machine in areas with high temperature or high humidity This may result in the machine not working properly Read Fully Understand Th...

Page 4: ...NTS 3 Counterfeit Detector PRODUCT VIEW Detection Guide Micro Print Magnifier Lens Ultraviolet Bulbs Magnetic Head Watermark Verification Window UV FL Light Selector Switch Power Switch located on bac...

Page 5: ...the back of the machine 3 Flip the UV FL light switch to select which light you want on 0 means UV and I means FL A 4 Place bill under the verification window B 5 Look through the verification window...

Page 6: ...Detection 1 Rub the area of the bill that is supposed to have magnetic ink on the magnetic head 2 If magnetic ink is present the unit will beep and the red magnetic indicator will turn on For Waterma...

Page 7: ...n the dust on the ultraviolet bulb with a dry towel to maintain ultraviolet light quality 2 Be certain to switch the power off when finishing detection to ensure long bulb life 3 Disconnect the power...

Page 8: ...s will be the responsibility of the purchaser Return defective product in original packaging to the address below Royal Sovereign International Inc requires reasonable proof of your date of purchase f...

Reviews:

Related manuals for RCD-2000