Installation instructions
Roxtec RM PE systems
Safety information
Roxtec recommends that all installations
are performed without facility operation.
Follow national regulations and installation
codes. Any action affecting the routed
service should be performed according to
manufacturer recommendations.
Roxtec RM PE module
Roxtec RM PE solid module
Components
Module size
For cable outer diameter
min-max
RM 15 PE
3-11
RM 15w40 PE
3.5-10.5
RM 20 PE
4-14.5
RM 20w40 PE
3.5-16.5
RM 30 PE
10-25
RM 30H90 PE
10-25
RM 40 10-32 PE
9.5-32.5
RM 40 PE
21.5-34.5
RM 40H80 PE
21.5-34.5
RM 60 24-54 PE
24-54
RM 60 PE
28-54
RM 80 PE
48-71
RM 90 PE
48-71
RM 120 PE
67.5-99
Roxtec RM PE modules
measures in millimeters (mm)
Roxtec RM PE solid modules
Module size
RM 10/0 PE
RM 15/0 PE
RM 20/0 PE
RM 30/0 PE
RM 40/0 PE
RM 60/0 PE
RM 30H90/0 PE
RM 40H80/0 PE
RM 10w120/0 PE
RM 5w120/0 PE
Note:
The range of the modules indicates the smallest diameter of the exposed cable shield to the largest diameter of the cable
jacket. Modules with core can be used as spare parts.