
COMEO - INSTRUCTIONS FOR THE USER
ROXELL - 001 - 4215
I- 8
TROUBLE SHOOTING GUIDE
Switch off the main switch first.
Use personal protective equipment.
DANGER
ACTIONS IN GREY BACKGROUND MUST BE DONE BY A TECHNICALLY TRAINED PERSON.
PROBLEM
CAUSE
CORRECTIVE ACTION
1.None of the feeder
lines run.
No current.
Replace defective fuses or reset circuit breakers.
Check current supply to the house.
Defective time clock.
Replace defective clock.
Time clock not properly set.
Readjust tabs.
2.One/more lines do
not run.
Pans are empty
Wires from motor damaged.
Measure current in motor wires. Replace wires if
defective.
Motor protection switched off.
See points 3. & 4. Reset motor overload button.
Defective sensor/minimum switch
control unit or 100kg hopper.
Check control unit sensor or switch. Replace if
necessary.
3.Motor is often
overloaded.
Oil on auger overloads the motor.
Clean the auger by running repeatedly 25kgs of
feed through the line.
Not enough current supply to the
motors.
Check current supply at motor location. Start the
motor. Measure start current on motors. Wiring
must be thick enough to guarantee good operation
of the system.
Object blocks the auger. Motor runs,
then stalls. Feed sticks to the tubes.
Check if there are no objects in the boot, the control
unit and the drop holes of the feeder pans. Remove
any objects.
4.Auger stalls.
Anchor bearing worn out or broken.
Replace bearing.
Gently
slide auger back into
the tubes. Don't let it jump back : your
finger
or
the
bearing
could be
damaged
.
Auger not enough stretched.
Shorten the auger.
Object blocks the auger.
Remove the object.
5.Tubes / boot wear
rapidly,
much noise when
system runs.
Auger kinked or bent at the wear
point.
Auger end overlaps the anchor end.
Make sure not to kink the auger when using
gripping pliers. Auger must not overlap the anchor
end.
6.Not enough feed
supplied to fill up
the lines.
Flex-Auger drop holes are too small
or point upwards.
Make
holes
wider/turn
tubes
with
holes
downwards.
Flow regulator in boot of feed supply
system blocks passage of the feed.
Adjust flow regulator to get a higher capacity.
Flex-Auger capacity is too low.
Check the capacity of the Flex-Auger according the
specifications.
Check the installation of the Flex-Auger.
Not enough time set on the time clock. Extend operation time per meal.
7.Feed drops
directly on the 12
fin support.
Pan not installed over the hole.
Remove the top support. Install the pan ass'y over
the hole and the lips.
Summary of Contents for CoMeo
Page 8: ......
Page 9: ...I 1 PART I INSTRUCTIONS FOR THE USER ...
Page 10: ...COMEO INSTRUCTIONS FOR THE USER ROXELL 001 2415 I 2 ...
Page 22: ......
Page 57: ...PART III INSTALLATION INSTRUCTIONS ...
Page 58: ...HAIKOO INSTALLATION INSTRUCTIONS ROXELL 009 2313 ...
Page 70: ...COMEO INSTALLATION INSTRUCTIONS ROXELL 009 2415 III 14 FIGURE 20 TO INSTALL THE MAIN CABLE ...
Page 82: ...COMEO INSTALLATION INSTRUCTIONS ROXELL 009 2415 III 26 FIGURE 54 FIGURE 55 CLICK CLICK 2x 2x ...
Page 97: ...ROXELL 001 1020 COMEO INSTALLATION INSTRUCTIONS III 41 FIGURE 87 20100244 10112548 FIGURE 88 ...
Page 99: ...ROXELL 001 1020 COMEO INSTALLATION INSTRUCTIONS III 43 FIGURE 95 6 FIGURE 96 ...
Page 100: ...COMEO INSTALLATION INSTRUCTIONS ROXELL 001 1020 III 44 FIGURE 97 4x FIGURE 98 1 2 ...
Page 102: ...COMEO INSTALLATION INSTRUCTIONS ROXELL 001 1020 III 46 FIGURE 102 1 2 FIGURE 103 FIGURE 104 ...