GB
28
If your vacuum cleaner does not start
• The appliance is not plugged-in. Check that
the appliance is correctly plugged in.
If there is no suction
• An accessory, the tube, the flexible tube or the
pipe between the suction inlet (pt 12) and the
separator are blocked: unblock them.
• If the separator is clogged, remove the lid
(fig.19)
and clean the separator.
3 • Maintaining the HEPA filter
Remove the lid of the separator
(fig.19)
and
unscrew the separator
(fig.20)
to remove it
from its location.
Clean the inside and outside of the separator
using a cloth
(fig.21-22)
.
Remove the HEPA filter
(fig.23)
.
Rinse the HEPA filter in water under the tap
(fig.24)
. Do not put water in the HEPA filter .
Allow the filter to dry for at least 24 hours
before replacing it
(fig.24)
.
Replace the HEPA filter in its case
(fig.25)
IMPORTANT
If your HEPA filter is
damaged, you can obtain a replacement
from your retailer or Certified Service
Centres under reference ZR003401.
IMPORTANT
If suction is no longer
satisfactory after automatic cleaning of the
HEPA filter (see Cleaning and Maintenance
paragraph), it must then be cleaned manually.
TROUBLESHOOTING
IMPORTANT
Do not use detergents, or
aggressive or abrasive products. The
transparency of the dust compartment
and/or the separator cover may change in
time but this does not affect the
performances of the appliance.
• If the HEPA filter is saturated, see page 27 and
28 paragraphs 2 and 3. If the HEPA filter is
damaged, replace it (Ref. ZR003401).
If the suction of your vacuum cleaner has
dropped, it makes a noise and whistles
• An accessory, the tube, the flexible tube or the
pipe between the suction inlet (pt 12) and the
separator are partially blocked: unblock them.
• If the dust box is full, empty and clean it (see
paragraph 1).
• The separator cover is not correctly in place.
Close the separator cover correctly
(fig.27)
.
and screw in the separator
(fig.26)
.
Again close the separator lid firmly
(fig.27)
.
4 • Cleaning your vacuum
cleaner
Clean the housing of the vacuum cleaner
with a soft and humid rag and let dry with a
dry rag
(fig.28)
.
Wash the dust compartment in clear water,
then dry it with a dry cloth.
IMPORTANT
As soon as your vacuum
cleaner starts to malfunction, and before
performing any checks stop the appliance by
pressing the Start/Stop switch.
CAUTION
Do not touch or rub the folds of
the HEPA filter. Allow the HEPA filter to dry
completely before replacing it on the
appliance.
IMPORTANT
The HEPA filter should be
cleaned at least once a year.
ROWENL19-735361:CLEAN POWER 1/07/08 15:45 Page 28