Current Limit
– Circuit Capacity (set for each circuit) – Max 60Amps total load
A current limit is assigned to each of the six circuits. Current limits can be set in 1 amp increments up to the max for each
circuit. Circuit #5 can be set to 20A but should only be used for intermittent applications like a horn
.
Refer to the
specifications of your accessory to determine the appropriate current limit.
To allow for slight variances, it’s typically
advisable to set the current limit with a slight margin (25%) above the standard current draw of any accessory. This is only
a guideline recommendation, and you should always check with the manufacturer of your accessory to determine the
maximum current setting.
Shutoff and Startup Delay Time
Startup Delay: 0-240 seconds -
This setting applies to all circuits regardless of switching mode.
The feature allows all of the available battery power to be used for starting prior to powering your accessories. Once
triggered, the PDM60 will remain off until the startup delay period expires.
Shutoff Delay: 1-600 seconds - This setting only applies to circuits set for
‘time delay off”
.
When the trigger signal is turned off, the circuit will remain live for the specified period of time then automatically turn off.
During the delay off period, all other circuits will remain in the inactive “orange” mode. A setting of “0” in the shutoff delay
field defaults to the maximum time of 600 seconds.
Testing
Before installing your PDM60 and anytime you change the programming, we recommend testing the functionality. This
can be done easily by connecting the power and ground leads of the PDM60 to your battery then holding the ignition
trigger on the positive battery terminal. You can verify your settings once the PDM60 activates. Time off delays can be
checked by removing the ignition trigger and waiting for the shutoff delay time to expire. Your specific configuration may
require a different testing steps.