Page
1
of
4
Instruction Manual
Thank you for your purchase. The PDM60 was designed with one goal in mind: to provide you, the owner, with years and
years of superior, hassle free electrical performance.
Package Contents:
1 - PDM60 Power Distribution Module
1
– Programming cable
1 -
Black 9” ground cable with protection boot
6 -
¼” ring terminal – used on your accessories’ ground wires for connections to ground points/ground bus cable
1 - 6MM bolt/nut - used for connecting all accessory ground wires to the main ground cable
6 - Posi-Lock Connectors
– one per circuit output wire – to allow for secure connections, and quick & easy installation
1 - Posi-Tap Connector
– the tap connector is to be used on the “Ignition Trigger” wire – tap into any switched circuit
Posi-Tap
Posi-Lock Programming Cable PDM60 Module
Overview:
The PDM60 provides 6 indi12V output circuits with a total load handling capacity of 60 Amps. This device is designed to
connect directly to a primary (12V) vehicle battery and efficiently power, protect and monitor the supply of power to your electronic
devices. A stock configuration is installed on all PDM60 units when they ship from the factory and is ready to use right out of the
package. The option to change some of the parameters is available by programming the PDM60 using the programming cable and a
computer with usb.
Stock Configuration
Wire Color Circuit/LED Max AMP Load Switched Via Delay ON Delay OFF
White 1 5 Amps Ignition Trigger 7 seconds None - Instant
Purple 2 5 Amps Ignition Trigger 7 seconds None - Instant
Yellow 3 10 Amps
Ignition Trigger 7 seconds None - Instant
Red 4 15 Amps Ignition Trigger 7 seconds None - Instant
Brown 5 15 Amps Ignition Trigger 7 seconds None - Instant
Orange 6
10 Amps Ignition Trigger 7 seconds None - Instant