Page 4
HOPPER button to advance to the right hopper value. Use the COUNT SWITCHES
to set the value at 2. This value determines the number of coins to be dispensed
for a $1 bill; twice the amount of coins for a $2 bill.
R.
Press the VALUE button, the display will show 50 PAY ___ --- ___. Use the
COUNT SWITCHES BUTTONS to change the value for the left hopper to 10.
Press the HOPPER button to advance to the right hopper value. Use the COUNT
SWITCHES to change set the value to 10. This value determines the number of
coins to be dispensed for a $5 bill.
S.
At this point all of the programming changes needed for the kit have been made,
slide the function button down to the NORMAL OPERATING MODE. The display
will indicate Storing New Data.
T.
The walking blue dash will begin scrolling. The two green arrows on the validator
will begin blinking.
NON MC MODE - 3 QUARTERS AND 5 NICKELS FOR A $1 BILL & 19 QUARTERS AND
5 NICKELS FOR A $5 BILL
A.
Slide the BILL CHANGER CONTROL COMPUTER forward so it is easy to view the
blue display and access the programming buttons.
B.
Slide the mode switch upwards to the programming mode, the display will read
TEMP COUNTERS.
C.
Depending upon the vintage of the BILL CHANGER CONTROL COMPUTER, the
FUNCTION button may be labeled as FUNCTION or FUNCTION-ERROR RESET.
These instructions refer to the button as FUNCTION.
D.
Press the FUNCTION button, the display will read PERM COUNTERS.
E.
Press the FUNCTION button, the display will read PROGRAMMING __ __ __ __. If
a security code was entered earlier enter the code now.
F.
Press the FUNCTION button, the display will read MC PAYOUT. It must be set to
OFF. Use either of the COUNT SWITCHES BUTTONS to set this option to OFF.
G.
Press the FUNCTION button, the display will read HOP VAL; the value of coins for
the left hopper will be flashing. Press the VALUE button until the display reads
T1.
H.
Press the HOPPER button; the display will advance to the right hopper. Press the
VALUE button until the display reads T1.
I.
Press the FUNCTION button, the display will read ACCEPT 1; this is set to NO.
The NO and YES options are toggled using the COUNT SWITCHES.
J.
Press the VALUE button, the display will read ACCEPT 2; this is set to NO.
K.
Press the VALUE button, the display will read ACCEPT 5; this is set to YES.
L.
Press the VALUE button, the display will read ACCEPT 10; this is set to NO.
M.
Press the VALUE button, the display will read ACCEPT 20; this is set to NO.
N.
Press the VALUE button, the display will read ACCEPT 25; this setting must be set
to YES.
O.
Press the VALUE button, the display will read ACCEPT 25A; this setting is set to
NO.
P.
Press the VALUE button, the display will read ACCEPT 50; this is set to YES.
Q.
Press the FUNCTION button, the display will show 25 PAY ___ --- ___. Use the
COUNT SWITCH BUTTONS to set the value for the left hopper to 3 (quarters).
Press the HOPPER button to advance to the right hopper value. Use the COUNT
SWITCHES to change the value to 5 (nickels). This value determines the number
of coins to be dispensed for a $1 bill; twice the amount of coins for a $2 bill.
R.
Press the VALUE button, the display will show 50 PAY ___ --- ___. Use the
COUNT SWITCHES BUTTONS to change the value for the left hopper to 19
(quarters). Press the HOPPER button to advance to the right hopper value. Use
the COUNT SWITCHES to set the value at 5 (nickels). This value determines the
number of coins to be dispensed for a $5 bill.
S.
At this point all of the programming changes needed for the kit have been made,
slide the function button down to the NORMAL OPERATING MODE. The display
will indicate Storing New Data.