Rover Instruments MASTERSAT Evo User Manual Download Page 27

27

IndeX

  2  –  get to know your MASTEr SAT EVO

  4  –  Home and navigation

  5  –  Volume and Configuration 

  7  - 

SAT: Analyze Satellite Television Signals

 9 – SPECT: 

Spectrum 

Analyzer

 10  –  LIST: Show and select available MPEg TS services

 

10 – HELP: 

 

inspect the parameters of an unknown signal

 

11 – Special 

functions

 13  –  MEMOry:  channel plans and log files

 14   –  S.M.A.r.T. program

 14  –  Service & support web registration & Sw upgrades

 15  –  Procedure to upgrade software

 16  – 

MEMOry PLAn uPgrADES PrOCEDurE

 17  –  LI-IOn POLIMEr bATTErIES

 

17 – wArnIngS

 18  –  bATTEry TEST & bATTEry rEgEnErATIOn

 19  – 

Power supply (mains) & battery charge (CHrg) LED status

 

20 – METEr 

MAInTEnAnCE

 21  –  SErVICE notes & guarantee regulations

 22   

DISPOSAL of ELECTrOnIC EQuIPMEnT

 23  –  fault identification form

 

24 – Suggested 

values

 25  - 

Accessories

SAT

SAT

SPECT

SPECT

MPEG  SERVICE

MPEG  SERVICE

SPECIAL

SPECIAL

MEMORY

MEMORY

Summary of Contents for MASTERSAT Evo

Page 1: ...MASTERSAT MASTERSAT MASTERSAT MASTERSAT www roverinstruments com USER S GUIDE EXTENDED FREQUENCY ANALYZER WIDE BAND dSCR 16 10 16 10 ...

Page 2: ...RDWARE RESET SOFTWARE Keep the HOME key pressed for 10 and turn on again Switch on the meter immediately after keep the volume key pressed until a beep is heard Get to know your MASTER SAT EVO ARROW KEYS Press ENTER to SELECT Use the arrow keys to navigate Use the arrow keys to select a function from the menu Keep ENTER pressed for secondary functions ...

Page 3: ..._______________________________________________ RIGHT SIDE 1 IF RF input connector F type 75 Ω 2 RJ 45 LAN connector LEFT SIDE 3 Power supply input connector 12 V DC 1A 4 usb socket for SW upgrades and memory plans 3 4 1 2 ...

Page 4: ...eters Live picture Measurements Transponder info Transport Stream info Context sensitive menu Press the HOME key to go to the main menu use the ARROW keys to navigate to the SAT icon and press ENTER to select the measurement mode required use the ARROW keys to navigate in the screens and change values use the ARROW keys to change the value of an item NUMERICAL KEYBOARD Navigate in a numerical valu...

Page 5: ... from the volume screen In ON mode if no key is pressed after 30 seconds the display brightness is reduced and after 5 minutes the meter automatically turns off Press any key to temporarily reset the battery save mode Navigate in CONFIGURATION MENU in the volume screen Navigate in METER and set the TIMER OFF value required The meter will turn off after 5 or 10 minutes of inactivity Press any key t...

Page 6: ... O SELECTION If WIDEBAND extended frequency is selected in all Measurement and Spectrum displays V WB and H WB will be used in the POL BND polarization band field The EXTENDED band LNB has only two polarizations which contain the high and low satellite bands between 230 and 2340 MHz Press ENTER on LNB L O to chose the LNB type STANDARD or WIDEBAND ...

Page 7: ... h e n p r e s s Navigate in ZOOM and select the constellation square window to enlarge SAT channel plan screen Satellite information mux data is provided in cooperation with LyngSat www lyngsat com MPEG SERVICE MPEG SERVICE SAT Spectrum Analyzer MPEG service list Identifies the tuning parameters of a digital signal SAT Channel Plan Selection SAT SAT AnalYze Satellite Television Signals sat SAT SA...

Page 8: ...________________________________________________ NIT Info Visualization referring to an ASTRA 19 East transponder Touch VISUALIZE NIT Touch MENU from the MAIN MEASUREMENTS PICTURES Example 1 MPEG SERVICE MPEG SERVICE SAT Spectrum Analyzer MPEG service list SAT Channel Plan Selection ...

Page 9: ...trum analyzer screens Navigate in SPAN to modify the value or directly select the active span value In the spectrum menu among others you may set your markers your grid resolution the resolution bandwidth filter for more details and save your spectrum picture in the meter s memory This spectrum picture may be recalled and used for static analysis and comparison with the live spectrum It can also b...

Page 10: ...ital carrier o r In measurement mode when the lock icon is open the signal is not locked The help function will try to identify the tuning parameters of the selected digital carrier At the end of the search the word Found will be shown in the 3 boxes the meter automatically shows the measurement display and the picture of the selected carrier if available Navigate in HELP on the main menu The help...

Page 11: ...NS Buzzer Noise Margin graph_______________________ SPECIAL SPECIAL SPECIAL SPECIAL Navigate in SAT SCR SCR dSCR daSS LNBs Navigate in LNB TYPE and choose the LNB MULTISWITCH model Navigate in SCR USER and choose the user number to test USER 1 8 Press SPECT to display the spectrum or MEAS to start measuring or navigate in SCR CABLE TEST to see the SCR in spectrum mode and check the LNB MULTISWITCH...

Page 12: ...not happen continue looking for the right satellite Optimize the dish alignment and skew to obtain the maximum NsMAR value noise margin N B For a proper use of the sat finder function verify the tuning parameters for all three transponders frequency polarity band and symbol rate and the type of LNB you are using universal or quatro Go to the www Lyngsat Com site for more information Choose a satel...

Page 13: ...START SAVE to create a new log file DATA LOGGER run CHANNEL PLANS AND LOG FILES MEMORY MEMORY MEMORY Use the arrow keys to navigate N B 1 The STOP GO function will help you when running a LOGGER by asking you to move the cable lead to the appropriate LNB output SAT signal source 2 If LNB L O WIDE BAND is chosen in the satellite configuration menu select for the STOP GO TV WBand LNB During the logg...

Page 14: ...tly access the update Sw Area by clicking on the red Access Sw upgrade Area key You will also receive an e mail message reminding you of your chosen user name and the password assigned by rOVEr Keep it in a safe place for future access to the update Sw Area and so that you can download new Sw upgrades and or Memory Plans If you lose your user name or your Password assigned by rOVEr click on the fu...

Page 15: ... and turn it on 2 wait for the Start up phase of the Meter to finish correctly 3 Connect the uSB cable first to the Meter and then to the pc 4 Start up the roVer S M A r T program in your PC 5 In the rOVEr S M A r T program window click on instrument followed by upgrade Firmware 6 In the open window select the Sw upgrade rvr downloaded from the update Sw Area 7 Click on open and confirm the select...

Page 16: ...o finish correctly 3 Connect the uSb cable first to the Meter and then to the PC 4 Make sure that you have installed the PrO Version and start up the rOVEr S M A r T program in your PC 5 In the rOVEr S M A r T PrO program window click on Instrument followed by Connect Instrument 6 Click on Tools then Mem e and then Open Mem In the rOVEr S M A r T PrO program window 7 In the Open window select the ...

Page 17: ...rY cHArGer Do noT leAVe THe BATTerieS DiScHArGeD For lonG perioDS AlwAYS cHArGe THe BATTerieS AT niGHT For AT leAST 7 HourS eVen iF THeY Are noT coMpleTelY DiScHArGeD uSeFul inForMATion 1 The batteries supplied are high quality and tested individually the autonomy depending on the following conditions the Lnb power consumption Single Dual or Quadruple the external temperature with temperatures of ...

Page 18: ...ad end amplifiers etc Extract the conditional access module cam if it is present in your meter 2 The battery test takes approx 12 18 Hours according to the model charging discharging recharging activities and measurement of the battery autonomy during this time the meter must not be used At the end of the test the meter will turn off automatically In order to make sure that the test has been carri...

Page 19: ...porarily and will automatically reset OFF YES ON ON Batteries in fast charge OFF YES ON OFF Battery charge completed OFF WITH A POWER SUPPLY NOT FROM ROVER Flashing 0 5 SECONDS OFF 0 5 SECONDS ON OFF The meter does not turn on Check the mains power adapter it must be 12 Vdc and not 18 Vdc turning ON Indifferent FLASHES 15 TIMES OFF The meter is being turned on ON Indifferent FLASHING SIMULTANEOUSL...

Page 20: ...eratures over 60 C or 140 f Those temperatures can be easily reached when the meter is left in a car especially behind the windshield or in the trunk The LCD display and or other details may easily be damaged by the extreme temperature The internal battery may rapidly loose its efficiency if exposed to high or low temperatures This will result in reduced autonomy of the meter when powered by inter...

Page 21: ... plastic chassis etc b batteries 3 months from the date of purchase if original c bags and carrying cases including shoulder straps 5 The equipment can not be replaced and the guarantee is extended after the repair of a fault SerVice noTeS AnD proceDureS 6 The equipment can only be repaired by the manufacturer or by an authorized rOVEr Laboratories service center a Before returning the meter for r...

Page 22: ...specially regarding EMC and safety 10 rOVEr Laboratories instruments is recognised and is fully compliant with DVb regulations and specifications ETS 300 421 12 94 and is consequently marked with the DVb logo dISPoSAl of eleCtronIC eQuIPMent Disposal of electric electronic equipment applicable in all CEE countries and whereever separate waste collection system is applied This symbol on the packagi...

Page 23: ...play in the configuration menu if the meter does not switch on you can find the meter s serial number on the label placed on the back of the meter detAIled and ACCurAte deSCrIPtIon of fAult Please describe and attach the fault especially if OCCASIOnAL or if it occurs OnLy under certain conditions for example cool instrument or warm instrument after no minutes of operation etc we suggest you provid...

Page 24: ...le shows the suggested measurements at a user s socket for the main digital modulations DVB T2 GB COFDM PER 7 25 dB 28 dB 26 5 dB 29 5 dB 40 dBµV 50 dBµV 28 5 dB 31 5 dB MER 256 QAM 2 3 FEC MER 256 QAM 3 4 FEC MER 256 QAM 5 6 FEC ...

Page 25: ... tools and accessories Shoulder strap Battery charger power supply User guide CD F Female F Female connector QUICK F Male F Female connector NOTE This list of accessories is subject to change without notice and depends on the meter s configuration ACCESSORIES SUPPLIED ...

Page 26: ...26 NOTES ...

Page 27: ...d log files 14 S M A R T program 14 Service support web registration SW upgrades 15 Procedure to upgrade software 16 MEMORY PLAN UPGRADES PROCEDURE 17 LI ION POLIMER BATTERIES 17 WARNINGS 18 BATTERY TEST BATTERY REGENERATION 19 Power supply mains battery charge CHRG LED status 20 METER MAINTENANCE 21 SERVICE notes guarantee regulations 22 DISPOSAL of ELECTRONIC EQUIPMENT 23 Fault identification fo...

Page 28: ...arini 2 25019 Sirmione BS Italy tel 39 030 9198 1 fax 39 030 990 6894 product specification are subject to change without notice All trademarks used are properties of their respective owners wecare roverinstruments com 39 030 9198 299 skype only for call wecare roverinstruments Customer Support ...