15
VERTICAL CONTACT TOASTER
P/N 1010747 Rev. G 11/15
TROUBLESHOOTING
WARNING
To avoid possible personal injury and/or damage to the unit, inspection, test and repair of electrical equip-
ment should be performed by qualified service personnel. The unit should be unplugged when servicing,
except when electrical tests are required. Use extreme care during electrical circuit tests. Live circuits will
be exposed.
Problem
Possible Cause
Corrective Action
No Display.
Unit not plugged in.
Circuit breakers tripped.
Hi-Limit thermostat tripped.
Plug the unit into the proper electrical outlet.
Reset the circuit breakers.
Reset the Hi-Limit thermostat.
Conveyor does not turn. Compression settings incorrect.
Set HEEL to 2 and CROWN to D.
Safety Interlock Switch is not activating.
Cover is bent. Replace with P/N 0011491.
Switch is broken. Contact your Authorized
Service Agent.
Roller Tensioner bent or missing.
Adjust Roller Tensioner -13/16” (2.1 cm) or
the height of a U.S. Nickel coin - from the
bottom of the roller to the inner cover.
Install new Roller Tensioner (P/N 7000186).
Conveyor Belt Chain stretched.
Refer to the section titled Servicing Conveyor
Belts in this manual.
Motor drive chain is off sprocket.
Install chain and lubricate with CRC 3-36.
Motor does not operate.
Unplug toaster. Check all electrical connec-
tions. Replace motor - contact your mainte-
nance person or Authorized Service Agency.
Buns are sticking
Compression settings incorrect.
Set HEEL to 2 and Crown to D.
Belt wraps dirty or damaged.
Clean Belt Wraps as described in the
Maintenance section of this manual.
Inspect for damage (tears, hardened or brit-
tle) and replace if necessary.
Release Sheet dirty or damaged.
Clean Release Sheet as described in
the Maintenance section of this manual.
Replace if scratched, torn, or has holes.
Replace with P/N 7000249.
Roller Tensioner missing or out of posi-
tion.
Adjust Roller Tensioner -13/16” (2.1 cm) or
the height of a U.S. Nickel coin - from the
bottom of the roller to the inner cover.
Install new Roller Tensioner (P/N 7000186).
Conveyor Belt not turning.
Remove Heat Shield, turn the power ON,
and depress the Safety Interlock Switch but-
ton at the top of the unit. Verify drive mecha-
nism is functioning.
Conveyor Chains turn but Belt Wrap
does not.
Refer to the Maintenance section of this
manual.