Page 10 of 17
Pump cannot operate with an empty load or the speed will be too fast causing damage.
If acceleration is too fast or running very slow, stop operation and check to be sure there is
enough oil in the barrel. If there is insufficient oil, change the trolley and initialize the entire
system.
Start Up
If there are several pumps in the system, use the control valve to dispatch the air.
Open the main control valve. Make sure there is safe grounding between the oil valve and the
trolley (metal connection). Then, open the oil valve. Open the cut-off valve and the pump will run.
Close the oil valve.
If there are several pumps in the system, start-up each pump step-by-step with the instructions
above.
For perfect results, set up the minimum air pressure for each device.
The pump cannot operate under an empty load.
Relieve pressure before closing the pump.
Operating Instructions
⚠
WARNING
Wear ANSI Z87.1 compliant goggles and other protective gear while operating.
Do not exceed the maximum working air pressure of 175 PSI.
Never point the dispenser at people or animals.
Do not use the pump near open flames. Do not smoke during this operation.
The compressed air must be filtered to avoid dust and moisture into pump.
Do not use with any liquid besides the intended oil, lubricants, or antifreeze liquids. See owner's
manual for intended oil.
Pressure Relief
Injury to skin: To reduce the risk of serious injury from pressurized fluid, follow this procedure
whenever you are instructed to relieve pressure:
Stop dispensing
Check, clean, or service any system equipment
Install or clean dispensing devices
Note:
After initialize work, open the oil valve and the pump will start to work. Close the oil valve and
the pump stops working.
Summary of Contents for 58267
Page 13: ...Page 13 of 17 Parts Diagram ...