Accessories

 

 

Extension cable for the HygroClip S (used with model M22W) 

 
MOK-xx-DAT05: (xx = 1, 2 or 5 meters) 

 
 
 
 
 
 
 
 

 

Calibration cable for the HygroClip S 

 

The MOK-03-WIN cable is used to calibrate the HygroClip S probe independently from the M22 
transmitter. The MOK-03-WIN cable connects the HygroClip S probe to the COM port of a PC. 
This cable is shipped together with the Rotronic HW3 software which is used to read and 
calibrate the probe from the PC. 

 
 

 
 
 
 
 
 
 
 

The requirements for using HW3 are as follows: 

 

3 m 

 

PC

Pentium 233MHz or better 

Windows   

®

95/98,Me, XP or NT or 2000

®

Memory

64MB 

Disk Space

20MB free 

Drives

CD ROM drive required 

Monitor 

VGA or Super VGA 

Resolution

1024 x 768 or higher (set to small fonts) 

 

High Color 16Bit  (256 Color minimum) 

COM Port

RS232 (COM 1-4) 

Software

HW3   (includes - MSIE 4.0 Browser - Adobe

®

 Acrobat Reader) 

 

MS Internet Explorer: for best viewing, set fonts to smallest 

 

For more details see separate instruction manual provided with the HW3 software. 

 

Summary of Contents for HygroClip M22 Series

Page 1: ...HygroClip M22 Series 2 wire loop powered humidity temperature transmitters INSTRUCTION MANUAL 20020530...

Page 2: ...pendix 2 Calibration 17 Appendix 3 Accessories for the M22 Series 18 PLEASE READ THIS FIRST Check the product for any physical damage that may have occurred during shipment We carefully pack and routi...

Page 3: ...transmitter includes a base plate and a plug in electronics module During installation the base plate is mounted first and wired without the electronics module This is done at the same time as general...

Page 4: ...____________________ _ in_m22 doc The M22 series is available in the following configurations Model Measurement Circuit Type Installation M22W RH Temperature 2 Wire Loop Powered Wall mount surface or...

Page 5: ...ents may require using a foam filter consult ROTRONIC The HygroClip S measures relative humidity with a ROTRONIC HYGROMERTM C94 capacitive humidity sensor This well proven sensor offers exceptional du...

Page 6: ...s of both the water molecule and the hygroscopic polymer used in the sensor vary with temperature The HygroClip S probe uses the temperature data from the Pt100 RTD to provide automatic compensation f...

Page 7: ...ressure conditions resulting from excessive air turbulence d Immerse as much of the probe as possible in the environment to be measured e Prevent the accumulation of condensation water at the level of...

Page 8: ...ith just one of these terminals connected Measuring humidity or temperature only the humidity and temperature circuits of the M22 are independent one from the other Any output can be operated without...

Page 9: ...9 _____________________________________________________________________________ _ _________________________________________________________________________________ _ in_m22 doc...

Page 10: ...thin and bend easily If this happens correct the alignment by holding the sensor very gently with a pair of small flat nosed pliers Periodic calibration check of the probe Long term stability of the...

Page 11: ...11 _____________________________________________________________________________ _ _________________________________________________________________________________ _ in_m22 doc...

Page 12: ...ice Connector Pin Wire Color Signal 1 Temperature Lo 1 2 Temperature Hi 1 3 Humidity Lo 1 4 Humidity Hi 1 5 Ground 6 V power to service cable 7 Not Used 8 Not Used 9 Not Used 10 Digital signal from Hy...

Page 13: ...ip S probe to the COM port of a PC This cable is shipped together with the Rotronic HW3 software which is used to read and calibrate the probe from the PC The requirements for using HW3 are as follows...

Page 14: ...e input 1 of the HygroPalm must be configured with the HW3 software analog signals probe 1 analog probe as per the instructions provided with the service cable In addition probe input 1 must be made t...

Page 15: ...calibration mode b Validation of the analog signals from the M22 transmitter by comparison with the digital signal of the HygroClip S This is done by switching the HygroPalm display between probe 1 a...

Page 16: ...ure output ranges 0 100 F or 0 100 C Output signals linear 4 20 mA max load 250 Accuracy at 68 77 F 20 25 C 0 5 RH 1 5 of reading 0 5 F 0 3 C Repeatability 0 3 RH and better than 0 2 F 0 1 C Humidity...

Page 17: ...s are available to calibrate the probe used with the M22 transmitter a Calibration of the probe connected to the M22 transmitter This requires a HygroPalm 3 indicator a service cable ACRL420 as well a...

Page 18: ...Clip S probe and to read the analog outputs of the transmitter MOK xx DAT05 Probe extension cable for M22W xx 1 2 or 5 meter MOK 03 WIN Calibration cable HygroClip probe with DAT05 connector to PC Ter...

Reviews: