background image

ROTRONIC AG

, CH-8303 Bassersdorf, Tel. +41 44 838 11 44, www.rotronic.com

  • ROTRONIC Messgeräte GmbH

,  D-76275 Ettlingen, Tel. +49 7243 383 250, www.rotronic.de

  • ROTRONIC SARL

, 56, F - 77183 Croissy Beaubourg, Tél. +33 1 60 95 07 10, www.rotronic.fr 

ROTRONIC Italia srl

I- 20157 Milano, Tel. +39 2 39 00 71 90, www.rotronic.it 

• ROTRONIC Instruments (UK) Ltd

, West Sussex RH10 9EE, Phone +44 1293 571000, www.rotronic.co.uk 

• ROTRONIC Instrument Corp

, NY 11788, USA, Phone +1 631 427-3898, www.rotronic-usa.com

ROTRONIC Canada Inc.

,Canada L8W 3P7, Phone + 1 905 754 5164, www.rotronic.ca

 

• ROTRONIC Instruments Pte. Ltd.,

 Singapore 159836, Phone +65 6376 2107, www.rotronic.sg 

• ROTRONIC Shanghai Rep. Offi ce

, Shanghai 200233, China, Phone +86 40 08162018, www.rotronic.cn

Se

rvi

ce 

in

terf

ace

+ VCC

– VCC

+ RH

– RH

+ T

– T

+ CO

2

– CO

2

Relay

V +

V −

(GND)

CO

+

RH + 
T +

RH − CO

T −

V+

CO

2

+

V −

(GND)

RH+
T +

RH −

CO

T −

86

86

45

32

62

62.5

62.5

86

32

120

65

84

60

62.5

96

62.5

A

Mechanical Installation

Note: 

In order to receive correct measurements, you must ensure that the measurement 

transducer is subjected to the fl ow of the air to be measured.

1.   Remove the mounting plate by loosening the screw.
2.  Attach the mounting plate at the desired position with 2 screws. 

Type R

Type S

Current output

Voltage output

Digital measurement transducer for humidity, temperature, and CO

2

.

Space mount version

SHORT INSTRUCTION MANUAL

3-core

Schematic Description

V

+

 

Power 

V - 

Power supply -

Temp + 

Temperature  analog

Temp - 

Temperature analog output -

RH + 

Humidity analog

RH - 

Humidity analog output -

CO

2+

 

Carbon dioxide analog

CO

2 -

 

Carbon dioxide analog output -

Relay 

Normally oper (NO)

A

Electrical Installation

 Caution:

 

Wrong supply voltages and excessive loads on the outputs can damage the 
transmitter.

Programming

The initial settings of the units are made in the factory to your order. The transmitters are 
adjusted in the factory, so checking and readjustment at installation time are not necessary. 
The units can be put into operation immediately after installation. Using the SW21 or HW4 
software and a standard mini-USB cable, you can make the following settings:
• Scaling of the analogue outputs
• 1-point adjustment for humidity
• 1-point adjustment for CO

2

• General settings

Congratulations on the purchase of your new CF1 series measurement transducer!
Please read these short instructions through carefully before installing the unit.

General Description

The units in the CF1 series are universal measurement transducers for transmission of humidity, 
temperature and 

CO

2

. You will fi nd more information at www.rotronic.com

Dimensions / Connections

CF1 S

ERIES

Procedure

• Connect the power supply
• Connect the measurement transducer to the PC via mini-USB cable
• Programm the measurement transducer using the SW21 or HW4 software
• Remove the power supply (The measurement transducer must be isolated
   from the power for at least 2 seconds)

Sources of Error

Measured values can be compromised by the following infl uences:

Temperature Errors

Through insuffi cient adaptation time, cold outer walls, heaters, direct sunlight, etc.

Humidity Errors

Through vapor, splashed water, dripping water or condensation on the sensor, etc. This does 
not, however, impair reproducibility or long-term stability, even when the sensor is exposed 
to high humidity or saturation with water vapor (condensation) for a prolonged period.

Carbon Dioxide Errors

Plants that are placed close to the measurement transducer neutralize the CO

2

. Objects or 

persons that radiate carbon dioxide can also indicate an increased CO

2

 content that is not 

strictly part of the surroundings that are to be measured.

Contamination

Through dust in the air. The choice of sensor fi lter depends on the degree of contamination 
at the measurement point, and the fi lter should be cleaned or replaced at intervals.

Periodical calibration of the sensor / transmitter

Both the temperature sensor and the associated electronics are very stable, and do not normally 
have to be changed or calibrated after calibration in the factory. The long-term stability of the
ROTRONIC Hygromer humidity sensor is typically better than 1 %RH per year. For maximum preci-
sion, we recommend calibration of the sensors approximately every six to twelve months. In the 
case of applications in which the sensor is subjected to pollutants, more frequent calibration may 
be necessary. Calibration can be carried out by the user onsite, or in the laboratory or workshop. 
The electronics do not normally need to be calibrated, and cannot be repaired in the fi eld. In case 
of problems, get in touch with Rotronic AG Service.

Technical Data  (Operation)

Temperature 

0...50 °C

Humidity  

0...100 %RH, non-condensing

CO

2

 

0...2000 ppm or 0...5000 ppm

Precision %RH (10...90 %RH) 

< 3 %RH

Precision °C at 23 °C ± 5 K 

± 0.3 K

 

± 1 K Type S with display

Precision CO

2

 (0...2000 ppm) 

± 40 ppm ± 3 % of the measured value

                          (0...5000 ppm) 

± 10 % of the measured value

 

Scaling the analog output signals

Humidity 0..100 %RH
Temperature 

-100...250 °C

CO

2

 

0...2000 ppm or 0...5000 ppm

Outputs 

Current or voltage signal

Relay 

Each parameter can be set via software

Terminal Confi guration / Wiring Diagrams

Using the table "Supply Voltage / Technology", identify the type, so that you can use the 
following connection schematics:

Power Supply

Type

Supply voltage

Load

Output

HF132

12..28 VAC / 15..40V DC

Max.500 

4..20 mA

HF135

12..28 VAC / 15..40V DC

Max.10 k

0..10 V

Summary of Contents for CF1 Series

Page 1: ...ion at www rotronic com Dimensions Connections CF1 SERIES Procedure Connect the power supply Connect the measurement transducer to the PCvia mini USB cable Programm the measurement transducer using the SW21 or HW4 software Remove the power supply The measurement transducer must be isolated from the power for at least 2 seconds Sources of Error Measured values can be compromised by the following in...

Page 2: ...nden Sie unter www rotronic com Abmessungen Anschlüsse CF1 SERIE Vorgehensweise Anschluss der Spannungsversorgung Verbindung des Messumformes mit dem PCvia mini USB Kabel Programmierung des Messumformers mit SW21 oder HW4 Software Entfernen der Spannungsversorgung Der Messumformer muss für min 2 Sekunden von der Spannung getrennt sein Fehlerquellen Messwerte können durch folgende Einflüsse beeinträ...

Page 3: ...com Dimensions raccordements SÉRIE CF1 Procédure Raccordement de la tension d alimentation Raccordement du transmetteur de mesure avec le PC par un câble mini USB Programmation du transmetteur de mesure avec le logiciel SW21 ou HW4 Déconnexion de la tension d alimentation le transmetteur doit être déconnecté de l alimentation pendant au moins 2 secondes Sources d erreur Les valeurs mesurées peuven...

Page 4: ...ocedimento Collegamento all alimentazione Collegamento del trasmettitore al PCvia cavo mini USB Programmazione del trasmettitore con il software SW21 o HW4 Distacco dell alimentazione il trasmettitore va staccato per min 2 secondi dalla tensione Fonti di errore I valori di misurazione sono influenzati dalle seguenti condizioni Errore di temperatura Dovuto a tempi ridotti di adattamento parete ester...

Reviews: