Glass breakage function
If the window pane is shocked, the glass breakage sensor becomes active,
and drives the shading solution down to the lower limit position.
Briefly press the button. If the indicator lamp shines red, the glass breakage
function is switched off. To switch it back on, press the button again and hold
it down. The indicator lamp changes from red to green. The glass breakage
function is now switched on. To switch it off, press the button again and hold
it down. The indicator lamp changes from green to red. The glass breakage
function is now switched off.
The factory setting is for the glass breakage function to be
switched off.
TEST mode
This mode lets you test the functionality of the sensor. In TEST mode, the
shade function times are shortened from minutes to seconds. Hold the
manual/auto button pressed down until the indicator lamp flashes green twice.
The TEST mode is now active for 5 minutes.
Manual/auto button
The manual/auto button allows you to switch the automatic drive commands
(e.g. sun protection function, twilight function) on and off.
In manual mode the indicator lamp gives a short red flash after operation.
In automatic mode the indicator lamp gives a short green flash after operation.
Press the manual/auto button again to change over.
Indicator lamp
A drive command is signalled by illumination of the indicator lamp.
Green: upward travel - Red: stop - Yellow: Downward travel
When the battery starts to lose power, the indicator lamp flashes when trans-
mitting.
The transmission strength and the radio range decrease as battery power de-
clines. The battery must be replaced if the indicator lamp no longer lights up
when a button is pressed.
24 - en