background image

2

ENGLISH

Contents

Page

1       Introduction ......................................................... 3

2       Operating instructions ........................................ 4

2.1    On/Off ............................................................................. 4
2.2     Turn on countdown ....................................................... 4
2.3     Normal display ............................................................... 5
2.4     Backlit display ................................................................ 5
2.5     Max ................................................................................ 5
2.6     Hold ................................................................................ 5

3       Checking for CO ................................................... 6

3.1    Visual indicator .............................................................. 6
3.2    Audiable & vibrating alarm ........................................... 7

4       Battery information ............................................. 8

4.1    Replacing the battery .................................................... 8

5       Troubleshooting .................................................. 9

6       Specifications ......................................................10

7       Cleaning ..............................................................10

8       Cold weather precautions ..................................11

9       Electromagnetic compatibility ...........................11

Summary of Contents for RO 77

Page 1: ...1 ENGLISH RO 77 rothenberger com MAN00149 RO 77 EN Instructions for use ...

Page 2: ... 3 Normal display 5 2 4 Backlit display 5 2 5 Max 5 2 6 Hold 5 3 Checking for CO 6 3 1 Visual indicator 6 3 2 Audiable vibrating alarm 7 4 Battery information 8 4 1 Replacing the battery 8 5 Troubleshooting 9 6 Specifications 10 7 Cleaning 10 8 Cold weather precautions 11 9 Electromagnetic compatibility 11 ...

Page 3: ...ata Hold Back lit display Battery Indication Warning Carbon monoxide is life threatening even at relatively low concentrations Be sure you understand the risks before investigating potential leaks This monitor measures combustion gases that may be toxic in relatively low concentrations This monitor must only be used by trained and competent persons after due consideration of all the potential haza...

Page 4: ...the ON button Only switch ON outdoors or where no CO is present it automatically zeros in 50 seconds During countdown the display shows time remaining as two digits Be sure to switch on in fresh air well away from boiler flues vehicle exhausts smokers and any other potential sources of CO The countdown starts at 50 When the countdown reaches 00 the meter will set its sensor to zero and display CO ...

Page 5: ... battery life Press to display the highest reading detected while the meter is switched ON Press again to display current value Holds value when button is pressed Freezes the display with the CO reading at the time the HOLD button is pressed Press again to display current value 2 3 Normal display 2 4 Backlit display 2 5 Max 2 6 Hold CO ppm ...

Page 6: ...are switched off and that the space is evacuated and ventilated before anybody returns to the area Where CO spillage or migration has been detected the procedures defined for Room CO Testing as part of CPA1 should be adopted If you are in any doubt about what to do seek expert advice Where CO spillage or migra tion has been detected the procedures defined for Room CO Testing as part of CPA1 should...

Page 7: ...llowable concentration for an 8 hour period without any known health risks according to the Department of Health and BS7967 30 ppm The maximum allowable concentration for competent persons to work in when investigating reports of fumes according to BS7967 200 ppm Mild headache fatigue dizziness and nausea after 2 to 3 hours 400 ppm Frontal headache and nausea within 1 to 2 hours Life threatening a...

Page 8: ...al warnings before switching off Warning Do not ignore the warnings as your monitor will no longer be functioning and your safety may be compromised The battery compartment is located underneath the belt clip To access the battery compartment the belt clip must be lifted at its pivot end and be rotated The pivot is keyed to prevent rotation in normal use and is spring loaded Full battery indicatio...

Page 9: ...now the appropriate ac tions to take to protect yourself and others Before switching off the mon itor always expose it to fresh air until the reading falls below 5 ppm Note that the readings fall much more slowly than they rise so you may need to wait some minutes Lift the clip at the pivot end against the spring by a few millimetres and then rotate the clip clear of the battery compartment Remove...

Page 10: ...t Take care to avoid moisture entering the sensor s grill and after cleaning leave the product in a warm dry place to allow any surface dampness to evaporate Under no circumstance should any solvent cleaner be used as this may cause damage to the plastic case display and sensor Range 0 999 ppm Resolution 1 ppm Accuracy 3 ppm 0 to 100 ppm 5 reading 101 ppm Audible alarm Preset at 30 ppm Visual alar...

Page 11: ...ires electronic equipment not to generate electromagnetic disturbances exceeding defined levels and have adequate immunity levels for normal operation Specific standards applicable to this meter are stated below As there are electrical products in use pre dating this Directive they may emit excess electromagnetic radiation levels and occasionally it may be appropriate to check the meter before use...

Page 12: ... tested for compliance with the following generic standards EN 61000 6 3 2011 EN 61000 6 1 2007 and is certified to be compliant Specification EC EMC KI RO 77 1 details the specific test configuration performance and conditions of use ...

Page 13: ...SAFETY WARNINGS IN THE MANUAL Register your RO 77 to create your KAM dashboard Simple online booking on www kane co uk Automatic reminder when due for recertification FREE POSTAGE returning your Rothenberger analyser SAME DAY annual FGA recertification OR YOUR MONEY BACK Register your RO 77 4 ...

Page 14: ... 65779 Kelkheim Germany Telefon 49 6195 800 0 Telefax 49 6195 800 3500 info rothenberger com ROTHENBERGER UK LIMITED 2 Kingsthorne Park Henson Way Kettering Northants NN16 8PX Tel 44 0 1536 310300 Fax 44 0 1536 310600 E info rothenberger co uk rothenberger com ...