Roth LuciPac A3 Aqua Instructions For Use Download Page 5

 

 

 

 

 

 

LuciPac

®

 A3 Aqua

 

 

20 pieces 

1ENK.1 

 

 

100 pieces 

1ENK.2 

 
 

 
 
 
 

Carl Roth GmbH + Co. KG 

Schoemperlenstraße 3-5 

• 76185 Karlsruhe • P.O. Box 100121 • 76231 Karlsruhe 

Phone: +49 (0) 721/ 5606-0 

• Fax: +49 (0) 721/ 5606-149 • [email protected] • www.carlroth.com 

The company is a limited partnership with headquarters in Karlsruhe, reg. court Mannheim HRA 100055. Roth  Chemie GmbH, with headquarters in Karlsruhe,  
reg. court Mannheim HRB 100428, is the personally liable partner. Managing Director: André Houdelet.  Sales tax identification number: DE 143621073.    

   

sse 07/2021

 

 

Summary of Contents for LuciPac A3 Aqua

Page 1: ...tored at a low temperature 2 C to 8 C 35 6 F to 46 4 F for long term storage The kit can be stored below 25 C 77 F for up to 14 days or below 30 C 86 F for up to 5 days before opening an aluminum bag without any adverse effect on the long term stability Do not freeze the device We recommend that you use all 20 sampling devices in a single bag at one time after opening an aluminum bag If you have l...

Page 2: ...rase pyruvate orthophosphate dikinase PPDK and a pyruvate kinase PK The method produces a defined amount of luminescence proportional to the amount of adenosine triphosphate ATP adenosine diphosphate ADP and adenosine monophosphate AMP in a sample Firefly luciferase emits light in the presence of ATP and luciferin The AMP generated from this reaction is converted back to ATP using the PPDK while e...

Page 3: ...ted environment 2 C to 8 C 35 6 F to 46 4 F High temperatures may cause product performance to drop 5 Do not subject the device or any part of it to direct sunlight for long periods of time Strong light may cause product performance to drop 6 Do not touch any of the parts inside the device particularly not any part of the sampling stick comb itself with a finger or other object before use Touching...

Page 4: ... sampling stick to the main body casing and push it all the way into the main body 5 Push firmly onto LuciPac A3 Aqua casing and agitate 6 Allow the leftover luminescent reagent to thoroughly dissolve 7 Insert the LuciPac A3 Aqua into the Lumitester to measure the results Press ENTER 8 Remove the LuciPac A3 Aqua case from the measuring chamber 8 Safety recommendations Please observe the following ...

Page 5: ...606 0 Fax 49 0 721 5606 149 info carlroth com www carlroth com The company is a limited partnership with headquarters in Karlsruhe reg court Mannheim HRA 100055 Roth Chemie GmbH with headquarters in Karlsruhe reg court Mannheim HRB 100428 is the personally liable partner Managing Director André Houdelet Sales tax identification number DE 143621073 sse 07 2021 ...

Reviews: