Parameter settings
FA ROTEX RoCon mb • 09/2017
51
6.12 "Basic Configuration" parameter level
This parameter level only appears:
– during initial commissioning if the answer selected for the
"Use Standard Config?" prompt was "No", or
– after the [System Config] parameter has been set to "Inactive"
or "Delete" in the "
"Configuration"
rotary switch setting,
"Setup"
level.
6.13
Parameter levels of the RoCon M1 mixer module
The parameter levels, parameter meanings, setting ranges and
connected functions are basically described in the same way as
in the previous sections.
An unlimited scope of available parameters exists at the indi-
vidual levels.
Only the corresponding sections are referred to below. Signif-
icant differences are explained in more detail.
Rotary switch setting: Info
See chap. 6.10.
On setting a control panel to "Mix Valve #X" (terminal function),
the displayed values refer to the components (pump, mix valve,
…), connected to the RoCon M1, of the mixer circuit assigned via
the device ID.
On setting a RoCon U1 room station assigned to the mixer
module via the heating circuit ID to "Living Room", the parameter
[T-Room adj] is available. The target room temperature can be
changed in the range -5 K to +5 K with the rotary button. This
function is not available if the RoCon U1 is used as a remote
control in terminal function.
Rotary switch setting: Operating Mode
See chap. 6.4.
Rotary switch setting: Set Temp Day
See chap. 6.5.
Rotary switch setting: Set Temp Night
See chap. 6.6.
Rotary switch setting: DHW Set Temp
No function.
Rotary switch setting: DHW Install
No function.
Rotary switch setting: Time Program
See chap. 6.8.
Rotary switch setting: Configuration
Rotary switch setting: Remote Param
See chap. 6.9.
Parameters
Description
Access
Setting range
Min / Max
Factory
setting
Incre-
ment
BE
HF
Boiler Function
Setting of the system functionality of the device in the RoCon system (do not change the factory
setting).
The default value of this parameter is "Single", and thus applies to a ROTEX HPSU monobloc
compact in autonomous operating mode.
If the values "Slave 1" to "Slave 8" are set, the ROTEX HPSU monobloc compact operates as a
heating module and expects an optional cascade controller for the request.
These settings are not yet applicable.
N
E
Single,
Slave 1,
…
Slave 8
Single
-
Unmixed Circ Config Setting of the heating circuit ID for the direct heating circuit of the ROTEX HPSU monobloc com-
pact. The heating circuit ID must be unique throughout the entire RoCon system. There must not
be any overlap with the heating circuit IDs of optional mixer circuits ([HC Assignment] parameter,
see tab. 6-15).
N
E
0 - 15
0
1
BUS ID HS
The setting must not be changed if more than 1 heat generator is integrated in the RoCon sys-
tem. Several heat generators integrated in the heating installation must be regarded as a special
application. If necessary contact a ROTEX service technician.
N
E
0 - 7
0
1
Time Master
Activation of a system-wide time master. The time master synchronises all controllers in the
RoCon system with the time and date set on the time master. For all other control units in the
system, it is no longer possible to enter the time and date. There must only be one time master
in the entire system. The parameter is not available if the time master parameter is activated on
another controller in the RoCon system.
N
E
Off
On
On
-
System Config
The system configuration of the device, consisting of sensor configuration and data bus config-
uration, can be deleted, activated or deactivated with this parameter. If, when first starting up,
the query for use of the standard configuration is answered with "Yes", settings suitable the basic
configuration of the heat generator are automatically activated (see chap. 6.2.1, tab. 6-1).
N
E
Inactive,
Active,
Delete
Inactive
-
Tab. 6-14 "Basic Configuration" level parameters