Rotex RKHBRD011ADV17 RKHBRD014ADV17 RKHBRD016ADV17 Operation Manual Download Page 16

Operation manual

15

RKHBRD011~0Y17

Indoor unit for air to water heat pump system and options

4P403582-1B – 2017.09

Tips and tricks

Programming the next day(s)

After confirming the programmed actions of a specific day (i.e. after
pressing the   button for 5 seconds), press the 

 button once. You

can now select another day by using the 

 and 

 buttons

and restart consulting and programming.

Copying programmed actions to next day

In space heating program it is possible to copy all programmed
actions of a specific day to the next day (e.g. copy all programmed
actions from "

" to "

").

To copy programmed actions to the next day, proceed as follows:

1

Press the   button to enter the programming/consulting mode.

The actual mode is blinking.

2

Select the operation mode you would like to program by means
of the 

 and 

 buttons.

The actual mode is blinking.

You can leave programming by pressing the 

 button.

3

Press the   button to confirm the selected mode.

The actual day is blinking.

4

Select the day you would like to copy to the next day by means
of the 

 and 

 buttons.

The selected day is blinking.

You can return to step 

2

 by pressing the 

 button.

5

Press the   and 

 buttons simultaneously for 5 seconds.

After 5 seconds the display will show the next day (e.g. "

" if "

"

was selected first). This indicates that the day has been copied.

You can return to step 

2

 by pressing the 

 button.

Deleting one or more programmed actions

Deleting one or more programmed actions is done at the same time
as storing the programmed actions.

When all actions for one day have been programmed, make sure that
the display shows the highest action number you would like to save.
By pressing the   button for 5 seconds, you store all actions except
those with a higher action number than the one that is displayed.

E.g. when the   button is pressed when action number 3 is
displayed, actions 1, 2 and 3 are stored but 4 and 5 are deleted.

Deleting a mode

1

Press the   button to enter the programming/consulting mode.

2

Select the operation mode you would like to delete by means of
the 

 and 

 buttons.

The actual mode is blinking.

3

Press the   and 

 button simultaneously for 5 seconds to

delete the selected mode.

Deleting a day of the week

1

Press the   button to enter the programming/consulting mode.

2

Select the operation mode you would like to delete by means of
the 

 and 

 buttons.

The actual mode is blinking.

3

Press the   button to confirm the selected mode.

The actual day is blinking.

4

Select the day you would like to delete by means of the 
and 

 buttons.

The selected day is blinking.

5

Press the   and 

 button simultaneously for 5 seconds to

delete the selected day.

Operating the remote alarm option

An optional EKRP1HBA digital I/O PCB can be connected to the
indoor unit and be used to remotely monitor your system. This
address card offers 3 voltage free outputs:

Output 1 = THERMO ON/OFF 

this output will be enabled when your unit is in space heating
operation.

Output 2 = ALARM OUTPUT 

this output will be enabled when your unit is in error condition.

Output 3 = DOMESTIC HOT WATER MODE ON/OFF

this output will be enabled when your unit is in domestic water
heating operation.

For more details about the wiring connections of this option, refer to
the wiring diagram of the unit.

Operating the optional remote controller

If besides the main remote controller the optional remote controller is
installed as well, the main remote controller (master) can access all
settings while the second remote controller (slave) can not access
schedule settings and parameter settings.

Refer to the installation manual for more details.

4PEN403582-1B_2017_09.book  Page 15  Saturday, October 7, 2017  11:02 AM

Summary of Contents for RKHBRD011ADV17 RKHBRD014ADV17 RKHBRD016ADV17

Page 1: ...RKHBRD011ADV17 RKHBRD014ADV17 RKHBRD016ADV17 RKHBRD011ADY17 RKHBRD014ADY17 RKHBRD016ADY17 Indoor unit for air to water heat pump system and options 4PEN403582 1B_2017_09 book Page 1 Saturday October...

Page 2: ...d knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not pla...

Page 3: ...ge on page 7 The icon will display Hot water will be produced at next scheduled action When water heat up starts the icon will be blinking 1 second interval Manual storage one time water heat up refer...

Page 4: ...T AVAILABLE This icon is displayed whenever a non installed option is addressed or a function is not available A function not available can mean insufficient permission level or can mean that a slave...

Page 5: ...case not zero will display 31 ROOM TEMPERATURE ADJUST BUTTONS and These multi purpose buttons are used to adjust the current room temperature set point in normal operation mode or in schedule timer p...

Page 6: ...mode heating will be activated as required by the water temperature set point The set point can be set manually through the schedule timer or weather dependent automatic Selecting space heating operat...

Page 7: ...e Lo_A low outdoor temperature 3 01 High ambient temperature Hi_A high outdoor temperature 3 02 Set point at low ambient temperature Lo_Ti the target outgoing water temperature when the outdoor temper...

Page 8: ...dependent domestic water heating is turned ON 1 or OFF 0 If enabled the storage set point will be set weather dependent In case of a higher ambient temperature e g during summer time temperature of s...

Page 9: ...storage temperature is reached It can also be stopped at any time by pushing the button NOTE If weather dependent domestic water heating is enabled b 02 the storage temperature will be set automatica...

Page 10: ...there are no error conditions in leaving or returning water thermistors the heater kit can start to follow emergency operation Other operation modes Start up operation During start up the icon display...

Page 11: ...ule timer The actions programmed in the schedule timer will be executed automatically The schedule timer is enabled icon displayed or disabled icon not displayed by pressing the button Space heating R...

Page 12: ...ve until the next programmed command 19 00 occurs So in order to know the actual setting one should consult the last programmed command It is clear that the last programmed command may date from the d...

Page 13: ...ram depending on remote controller model 4 or 5 actions can be programmed per mode The same actions are repeated on a daily basis Take your time to enter all data accurately Try to program the actions...

Page 14: ...s to set the room temperature 11 Use the button to select to switch heating and the remote controller off to select automatic temperature calculation for leaving water temperature Use the and buttons...

Page 15: ...en action number 3 is displayed actions 1 2 and 3 are stored but 4 and 5 are deleted By pressing the button several times you return to previous steps in this procedure and finally return to normal op...

Page 16: ...er action number than the one that is displayed E g when the button is pressed when action number 3 is displayed actions 1 2 and 3 are stored but 4 and 5 are deleted Deleting a mode 1 Press the button...

Page 17: ...for a minimum of 5 seconds to enter FIELD SET MODE The icon 3 will be displayed The current selected field setting code is indicated 2 with the set value displayed to the right 1 2 Press the button t...

Page 18: ...w ambient temperature Lo_Ti 70 25 80 1 C 03 Set point at high ambient temperature Hi_Ti 45 25 80 1 C 4 Disinfection function 00 Status disinfection operation 1 ON 0 1 01 Disinfection operation day sel...

Page 19: ...04 Automatic maximum hot water tank storage temperature 70 55 75 1 C C Leaving water temperature limits 00 Installation related setting 80 37 80 1 C 01 Installation related setting 25 25 37 1 C 02 No...

Page 20: ...e information If the supply cord is damaged it must be replaced by the manufacturer its agent or similar qualified persons in order to avoid hazards During longer periods of standstill e g during summ...

Page 21: ...4PEN403582 1B_2017_09 book Page 1 Saturday October 7 2017 11 02 AM...