background image

Operation manual

13

RKHBRD011~0Y17

Indoor unit for air to water heat pump system and options

4P403582-1B – 2017.09

Programming space heating

Programming space heating is carried out as follows:

1

Press the   button to enter the programming/consulting mode.

2

Select the operation mode you would like to program by means
of the 

 and 

 buttons.

The actual mode is blinking.

3

Press the   button to confirm the selected mode.

The actual day is blinking.

4

Select the day you would like to consult or to program by means
of the 

 and 

 buttons.

The selected day is blinking.

5

Press the   button to confirm the selected day.

6

Hold down the   button for 5 seconds to program the detailed
actions.

The first programmed action of the selected day appears.

7

Use the   button to select the action number you would like to
program or to modify.

8

Use the 

 and 

 buttons to set the correct action time.

9

Use the 

 and 

 buttons to set the leaving water

temperature.

10

Use the 

 and 

 buttons to set the room temperature.

11

Use the 

 button to select:

-

: to switch heating and the remote controller  off.

-

: to select automatic temperature calculation for leaving 

water temperature

Use the 

 and 

 buttons to set the appropriate

shift value (refer to 

"Space heating operation ( )" on page 5

 for

more information about weather dependent set point).

12

Repeat steps 

7

 to 

10

 to program the other actions of the

selected day.

When all actions have been programmed, make sure that the
display shows the highest action number you would like to save.

13

Press the   button for 5 seconds to store the programmed
actions.

If the   button is pressed when action number 3 is displayed,
actions 1, 2 and 3 are stored but 4 and 5 are deleted.

You automatically return to step 

6

.

By pressing the 

 button several times, you return to previous

steps in this procedure and finally return to normal operation.

14

You automatically return to step 

6

, start again to program the

following day.

5 sec

5 sec

NOTE

Returning to previous steps in the programming
procedure without saving modified settings is done by
pressing the 

 button.

4PEN403582-1B_2017_09.book  Page 13  Saturday, October 7, 2017  11:02 AM

Summary of Contents for RKHBRD011ADV17 RKHBRD014ADV17 RKHBRD016ADV17

Page 1: ...RKHBRD011ADV17 RKHBRD014ADV17 RKHBRD016ADV17 RKHBRD011ADY17 RKHBRD014ADY17 RKHBRD016ADY17 Indoor unit for air to water heat pump system and options 4PEN403582 1B_2017_09 book Page 1 Saturday October...

Page 2: ...d knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not pla...

Page 3: ...ge on page 7 The icon will display Hot water will be produced at next scheduled action When water heat up starts the icon will be blinking 1 second interval Manual storage one time water heat up refer...

Page 4: ...T AVAILABLE This icon is displayed whenever a non installed option is addressed or a function is not available A function not available can mean insufficient permission level or can mean that a slave...

Page 5: ...case not zero will display 31 ROOM TEMPERATURE ADJUST BUTTONS and These multi purpose buttons are used to adjust the current room temperature set point in normal operation mode or in schedule timer p...

Page 6: ...mode heating will be activated as required by the water temperature set point The set point can be set manually through the schedule timer or weather dependent automatic Selecting space heating operat...

Page 7: ...e Lo_A low outdoor temperature 3 01 High ambient temperature Hi_A high outdoor temperature 3 02 Set point at low ambient temperature Lo_Ti the target outgoing water temperature when the outdoor temper...

Page 8: ...dependent domestic water heating is turned ON 1 or OFF 0 If enabled the storage set point will be set weather dependent In case of a higher ambient temperature e g during summer time temperature of s...

Page 9: ...storage temperature is reached It can also be stopped at any time by pushing the button NOTE If weather dependent domestic water heating is enabled b 02 the storage temperature will be set automatica...

Page 10: ...there are no error conditions in leaving or returning water thermistors the heater kit can start to follow emergency operation Other operation modes Start up operation During start up the icon display...

Page 11: ...ule timer The actions programmed in the schedule timer will be executed automatically The schedule timer is enabled icon displayed or disabled icon not displayed by pressing the button Space heating R...

Page 12: ...ve until the next programmed command 19 00 occurs So in order to know the actual setting one should consult the last programmed command It is clear that the last programmed command may date from the d...

Page 13: ...ram depending on remote controller model 4 or 5 actions can be programmed per mode The same actions are repeated on a daily basis Take your time to enter all data accurately Try to program the actions...

Page 14: ...s to set the room temperature 11 Use the button to select to switch heating and the remote controller off to select automatic temperature calculation for leaving water temperature Use the and buttons...

Page 15: ...en action number 3 is displayed actions 1 2 and 3 are stored but 4 and 5 are deleted By pressing the button several times you return to previous steps in this procedure and finally return to normal op...

Page 16: ...er action number than the one that is displayed E g when the button is pressed when action number 3 is displayed actions 1 2 and 3 are stored but 4 and 5 are deleted Deleting a mode 1 Press the button...

Page 17: ...for a minimum of 5 seconds to enter FIELD SET MODE The icon 3 will be displayed The current selected field setting code is indicated 2 with the set value displayed to the right 1 2 Press the button t...

Page 18: ...w ambient temperature Lo_Ti 70 25 80 1 C 03 Set point at high ambient temperature Hi_Ti 45 25 80 1 C 4 Disinfection function 00 Status disinfection operation 1 ON 0 1 01 Disinfection operation day sel...

Page 19: ...04 Automatic maximum hot water tank storage temperature 70 55 75 1 C C Leaving water temperature limits 00 Installation related setting 80 37 80 1 C 01 Installation related setting 25 25 37 1 C 02 No...

Page 20: ...e information If the supply cord is damaged it must be replaced by the manufacturer its agent or similar qualified persons in order to avoid hazards During longer periods of standstill e g during summ...

Page 21: ...4PEN403582 1B_2017_09 book Page 1 Saturday October 7 2017 11 02 AM...

Page 22: ...4PEN403582 1B_2017_09 book Page 2 Saturday October 7 2017 11 02 AM...

Page 23: ...4PEN403582 1B_2017_09 book Page 1 Saturday October 7 2017 11 02 AM...

Page 24: ...nd Nos partenaires l tranger Le nostre sedi all estero Neustros representantes en el extranjero Nasi partnerzy za granic Na i partne i v zahrani http de rotex heating com ueber rotex international 4P4...

Reviews: