32
FA ROTEX SC / SCS / HYC - 02/2013
8
x
Technical data
8.1.3 HybridCube (HYC)
Unpressurised (Drain Back) - DB
Unit
HYC 343/0/0-
DB
HYC 343/19/0-
DB
HYC 544/19/0-
DB
HYC 544/32/0-
DB
Basic data
Total storage capacity
litres
300
500
Empty weight
kg
51
59
87
93
Total filled weight
kg
351
359
587
593
Dimensions (L x W x H) without switching unit from
E-PAC
cm
59.5 x 61.5 x 164
79 x 79 x 164
Maximum permissible storage water temperature
°C
85
Heat consumption at stand-by and at 60 °C
kWh/24 h
1.3
1.4
Domestic hot water (stainless steel 1.4404)
potable water capacity
litres
27.9
29.0
Maximum operating pressure
bar
6
Domestic water heat exchanger surface
m
2
5.8
6.0
Storage tank charging heat exchanger (stainless steel 1.4404)
Water capacity heat exchanger
litres
—
13.2
9.9
18.5
Heat exchanger surface area
m
2
—
2.7
2.0
3.8
Solar heating backup (stainless steel 1.4404)
Water capacity heat exchanger
litres
—
—
2.3
Heat exchanger surface area
m
2
—
—
0.5
Thermal output data
Volume of hot water without reheating at draw-off
rate (8 l/min
3)
/12 l/min
4)
)
(T
KW
= 10 °C / T
WW
= 40 °C / T
SP
= 50 °C)
litres
—
184
3)
/ 153
4)
364
3)7)
/ 318
4)7)
328
3)8)
/ 276
4)8)
Volume of hot water without reheating at draw-off
rate (8 l/min
4)
/12 l/min
4)
)
(T
KW
= 10 °C / T
WW
= 40 °C / T
SP
= 60 °C)
litres
—
282
3)
/ 252
4)
540
3)
/ 494
4)
Volume of hot water without reheating at draw-off
rate (8 l/min
4)
/12 l/min
4)
)
(T
KW
= 10 °C / T
WW
= 40 °C / T
SP
= 65 °C)
litres
—
352
3)
/ 321
4)
612
3)
/ 564
4)
Reheating time (Wh) with a draw-off quantity
(bathtub: 140 l
5)
/ shower: 90 l
6)
)
(T
KW
= 10 °C / T
WW
= 40 °C / T
SP
= 50 °C)
min.
—
45
5)9)
/ 30
6)9)
25
5)10)
/ 17
6)10)
Pipe connections
Cold and hot water
inches
1" Outer thread
Heating flow / return flow
inches
1" Outer thread / 1" Internal thread
Solar connections
inches
1" Internal thread
Order number
14 05 52
14 05 53
14 05 60
14 05 62
Tab. 8 -3 Basic data HybridCube - Drain-Back
7)
Charging by heat pump and electric booster heater.
8)
Charging only by heat pump without electric booster heater.
9)
With heat pump HPSU 008.
10) With heat pump HPSU 016.