background image

4 Operation

User reference guide

14

08S18+23DA

Daikin Altherma – Low temperature split

4P495251-1 – 2017.12

4.9

Menu structure: Overview user settings

[2]

Main zone

Schedule
Heating schedule
Setpoint mode
Heating WD curve

[3]

Additional zone

Schedule
Heating schedule
Setpoint mode
Heating WD curve

[5]

Tank

Powerful operation
Comfort setpoint
Eco setpoint
Reheat setpoint
Schedule

[8.1]

Energy data

Electricity input
Produced heat

[7]

User settings

Language
Time/date
Holiday
Quiet
Electricity price
Gas price

[C]

Operation

Room

Space heating/cooling

Tank

[B]

User profile

[7.3]

Holiday

Activation
From
Till

[7.4]

Quiet

Activation
Schedule

[7.5]

Electricity price

High
Medium
Low
Schedule

[7.2]

Time/date

Hours
Minutes
Year
Month
Day
Daylight savings time
Format

[1.4]

Antifrost

Activation
Room setpoint

[1.5]

Setpoint range

Heating minimum
Heating maximum

[1]

Room

Schedule
Heating schedule
Antifrost
Setpoint range
Room sensor offset

[4]

Space heating/cooling

Operation mode

[8]

Information

Energy data

Malfunction history

Dealer information

Sensors
Actuators
Operation modes
About
Connection status

Setpoint screen

INFORMATION

Depending on the selected installer settings and unit type,
settings will be visible/invisible.

Summary of Contents for Altherma EHVZ04S18DA6VG

Page 1: ...r reference guide Daikin Altherma Low temperature split English User reference guide Daikin Altherma Low temperature split EHVZ04S18DA6V G EHVZ08S18DA6V G EHVZ08S23DA6V G EHVZ08S18DA9W G EHVZ08S23DA9W...

Page 2: ...the contact helpdesk number 16 7 Troubleshooting 16 7 1 To display the help text in case of a malfunction 16 7 2 To check the malfunction history 16 7 3 Symptom You are feeling too cold hot in your li...

Page 3: ...out this document Thank you for purchasing this product Please Read the documentation carefully before operating the user interface to ensure the best possible performance Request the installer to inf...

Page 4: ...the screen darkens Pressing any button or rotating any dial awakens the display The time of non interaction differs depending on the user permission level User or Advanced user 15 min Installer 1 h Di...

Page 5: ...cription Additional zone h3 h1 h2 h1 Heat emitter type Underfloor heating Fancoil unit Radiator h2 Leaving water temperature setpoint h3 Room thermostat type External control Hidden Leaving water temp...

Page 6: ...About the home screen On the home screen you can read out the most important settings that are meant for daily usage The setup of the unit is displayed in a schematic way See 4 2 1 Home screen on page...

Page 7: ...cheduling 1 Go to 1 1 Room Schedule 2 Select No 4 4 5 To change the desired leaving water temperature INFORMATION The leaving water is the water that is sent to the heat emitters The desired leaving w...

Page 8: ...he domestic water entering the DHW tank example 15 C At 00 00 the DHW tank is programmed to heat up the water to a preset value example Comfort 60 C During the morning you consume hot water and the DH...

Page 9: ...o check if quiet mode is active If is displayed on the home screen quiet mode is active To use quiet mode 1 Go to 7 4 1 User settings Quiet Activation 2 Do one of the following If you want to Then Com...

Page 10: ...7 2 Setting the energy prices In the system you can set the following energy prices a fixed gas price 3 electricity price levels a weekly schedule timer for electricity prices Refer to the installatio...

Page 11: ...e main zone in heating mode 3 2 Additional zone Heating schedule Program the desired leaving water temperature for the additional zone in heating mode 4 2 Space heating cooling Operation mode schedule...

Page 12: ...t C is displayed next to the copied day 3 Select Tuesday Mon Sat Wed Fri Thu Tue Sun User defined 1 C 4 Select Paste Copy Paste C Result Mon Sat Wed Fri Thu Tue Sun User defined 1 C 5 Repeat this acti...

Page 13: ...arameters for the weather dependent curve 2 5 for the main zone and 3 5 for the additional zone see below 4 8 1 Detailed screen with weather dependent curve When weather dependent operation is active...

Page 14: ...price C Operation Room Space heating cooling Tank B User profile 7 3 Holiday Activation From Till 7 4 Quiet Activation Schedule 7 5 Electricity price High Medium Low Schedule 7 2 Time date Hours Minut...

Page 15: ...lower desired leaving water temperature results in lower energy consumption and better performance Set the desired leaving water temperature in accordance with the heat emitter type Example Underfloo...

Page 16: ...r living room Possible cause Corrective action The desired room temperature is too low high Increase decrease the desired room temperature If the problem recurs daily do one of the following Increase...

Page 17: ...er Technical skilled person who is qualified to install the product User Person who is owner of the product and or operates the product Applicable legislation All international European national and l...

Page 18: ......

Page 19: ......

Page 20: ...4P495251 1 2017 12 Copyright 2017 Daikin...

Reviews: