Safety
6
BA ROTEX A1 BO - 10/2007
1.5
Instructions for operating safety
Training by the installer
• The handover includes training in the operation and monitoring of the oil condensing boiler using the operating instructions
by the installer.
• The handover should be documented by completing and signing the enclosed installation and training form with the engineer.
Fuel
• Use only the approved heating oils as fuel (see chapter 7 "Technical data").
Installation room
• Operate the oil condensing boiler only if sufficient combustible air supply is guaranteed. If operating the oil condensing boiler
independently of the ambient air with an air/flue system (LAS) with dimensions according to ROTEX-Standard, this is
automatically guaranteed and there will be no further conditions required of the unit installation room.
• Make sure that there is a supply air opening to the open air, of at least 150 cm
2
with ambient air dependent operation.
• Do not operate the oil condensing boiler dependent on ambient air in rooms with aggressive vapours (e.g. hair spray,
perchloroethylene, carbon tetrachloride), strong dust formation (e.g. workshop) or high atmospheric humidity (e.g. laundry).
• Always maintain the minimum distance away from walls and other objects (see chapter 3.2 and chapter 7).
Heating system
• Work on the heating system (e.g. installation, connection and initial start-up) should only be carried out by authorised and
trained heating experts.
• Switch off the mains supply before starting any work on the heating system and secure it against unintentional switch-on.
• The heating system must comply with the safety requirements of EN 12828 as an open or closed heating system.
• The safety valves must comply with DIN EN ISO 4126-1 and be type-tested. The safety valves must be installed in the safety
flow.
• Always operate the oil condensing boiler with the sound insulation hoods closed.
• The labels on the oil condensing boiler must not be removed or damaged.
Electrical installation
• All the control and safety devices in the oil condensing boiler are connected ready for operation and are tested. Modifications
on the electrical installation are dangerous and prohibited. Any resulting damages will be borne by the user/owner alone.
• Electrical installations may only be carried out by qualified electrical technicians under observance of the relevant electrical
guidelines and the regulations of the electric utilities company.
Air/flue system (LAS)
• The air/flue gas system (LAS) must not be modified arbitrarily by the operator. Modification to the combustion air supply and
the flue gas ducting must only be carried out by authorised and trained technicians
in consultation with the regional chimney
sweep
.
Disposal
• Through the environmentally-friendly design of the oil condensing boiler, ROTEX has complied with the requirements for
environmentally-friendly disposal.
• Proper disposal in compliance with the respective national regulations of the country of use is the responsibility of the
user/owner.
Documentation
• The technical documentation included in the scope of supply is a constituent part of the equipment. It must be stored in such
a way that it can be consulted at any time by the operator or the technicians.