IM No. : IM/V/0021, Rev. 2
Date: 06.11.2017
Page 2 of 6
IDENTIFICATION ON THE SOLENOID VALVE
a)
VALVE MARKING
Label on the
ROTEX
Solenoid Valve shows the following details:
(1)
Logo + Name & address of the Manufacturer
(2)
Valve Type / Code
51424
= Valve Model
Suffix
= Nil
6
= Orifice
2R
= Port Connection
B5
= Body Material
M8
= Manual Override
S2
= Seal Material
(3)
Work Order reference / Sr. No. of the Valve
(4)
Operating Pressure
(5)
Month & Year of manufacture
(6)
Valve Symbol
(7)
Media
(1)
ROTEX AUTOMATION LIMITED
VADODARA-390010, INDIA
FLUID CONTROL SYSTEM
CODE : 51424-6-2R-B5-M8-S2
ATM
2-10
MEDIA
AIR
DATE
9/2016
Wo. No.
16100650/10
(6) (2) (4) (3) (5) (7)
b)
SOLENOID MARKING
(1)
ROTEX
VADODARA
– 390010,
INDIA
(1)
(2)
Logo + Name of the Manufacturer
Solenoid Type
III
110V
=
=
Solenoid Size III
Solenoid Voltage
III-110V-DC-25-H
DC
= Solenoid Current
16100650-09/16
25
= Solenoid Construction
H = Solenoid Class H Insulation
(3) Work order No. Manufacturing Month / Year
(2)
(3)
(B)
MOUNTING/INSTALLATION PROCEDURE
:
1.
ENSURE THAT:
a)
While storing, keep the valve in cool, dry, dust free area.
b)
On receipt of the valve, in case if the same is to be removed from the sealed plastic bag for
inspection/testing, put them back with dust plugs on its ports and sealing the plastic bag as soon as the
inspection/testing is over.
c)
The valve should be removed from its card board and/or plastic bag just before the installation.
d)
Flush lines before installing the valve.
e)
To avoid pressure drop and to achieve optimum parameters, Pipe / Tube / Fitting from the source of
pressure to the valve and to the connected equipment should have ID which is
NW (Orifice) of the
valve.
f)
To avoid pressure drop, if more than one valve is being operated simultaneously from a common
header, then minimum ID of the header can be calculated as under.
ID Header =
(NW
2
n)
n = Number of Valves operating at a time and which are connected to a common header,
NW = Orifice of the Valve.
g)
Incorporate filter in the line to avoid hard particles entering into the valve.
h)
Do not try to drill any additional holes or machine, modify any of the valve components.
i)
Inlet pressure does not exceed rated pressure.
j)
Hemp-
Filaments, ’Jute’ or even Teflon-Ribbons are normally not required, as the port connections of
ROTEX Valve is accurately machined.
k)
Do not cover first two thread pitches with Teflon tape or sealant. To avoid over lap of the Teflon ribbon or
cuts generated while tightening, getting carried away into the valve.