IM No. : IM/V/00063  

Rev. 1 dtd. 23.05.2017 

Page 1 of 5 

 

MOUNTING, OPERATING, TESTING & MAINTENANCE INSTRUCTIONS 

FOR ROTEX 2/2 INTERNAL PILOT, DIAPHRAGM OPERATED, 

 INLINE, NORAMLLY OPEN SOLENOID VALVE  

MODEL: 24201, 24202, 2420V01, 24202V01, 24229, 24232 

 
 

ROTEX

 retains all rights to this publication. 

 

All details within this manual and the catalogue are subject to change without manner. 

 

ROTEX 

will not be responsible for any damage whatsoever arising from the use of the Solenoid Valve, due to misuse 

or incorrect installation or misinterpretation of the information contained herein. 

 

CONNECTION

 

 

VALVE TYPE 

FUNCTION 

IN 

OUT 

24201,  24202,  24201V01, 
24202V01, 24229, 24232 

NC 

 

(A)  OPERATING PRINCIPLE 

 
In de-energized condition of solenoid, applied pressure at Inlet port # 2, a part of media pressure passed from bleed 
hole of diaphragm to surrounding hole of Duse to tube hole to out let port # 1. thus, pressure released from top of the 
diaphragm assembly and it is moves up. In this state, Inlet port # 2 and Outlet port # 1 is connected. Media come from 
outlet. 
 
In  energized  condition  of  solenoid,  thus  plunger  assembly  moves  up  and  blocked  the  pilot  passage,  now  applied 
pressure at Inlet port # 2, media pressure act on the diaphragm assembly from bleed to keep downwards. In this state, 
Inlet port # 2 and Outlet port # 1 is disconnected. Media cannot come out.  

 

 
 
 
 

 

 
 
 
 

 

 

 
 