Filter exchange in detail
The figures show the XG 500 Basic/Design device without intake shutter
Loosen the four clamping screws on the bottom of the
device with an Allen key. Screw out the screws by
approx. 35 mm.
Lay all the filter cartridges in a disposal sack and clean
the air purifier housing.
Loosen the four inspection cover screws on the rear side
of the air purifier. Remove the inspection cover.
Insert the new filter cartridges. Always observe the
correct arrangement and air direction for the cartridges
when inserting them.
When finished, position the cover and tighten the four
clamping screws and the four inspection cover screws
again. Stand the air purifier up again and execute a test
operation.
Do you still have questions regarding exchanging filters?
Please feel free to contact us at: [email protected]
Remove the pre-filter from the housing. Then remove the
activated carbon filter/gas filter and the HEPA H14 filter.
Package
Article No.
for XG 500 FPX50050 PM Z-Line (pre-filter), Gas filter, HEPA H14
for XG 520 FPX52080 PM1 70% (pre-filter), Gas filter, HEPA H14
for XG 820 FPX82080 PM1 70% (pre-filter), Gas filter, HEPA H14