Before cleaning, turn off the power and 
unplug the unit.

It may cause electrical shock or injury.

Do not use the machine near flammable 
gas or combustibles, such as gasoline, 
benzene, thinner, etc.

It may cause an explosion or fire.

Do not drink or use the water drained 
from the unit.

It contains contaminants and could make 
you sick.

Do not take the water bucket out during 
operation.

It may cause bucket full protect of the unit 
and cause electric shock.

2. CAUTIONS

Do not use the unit in small spaces.

Lack of ventilation can cause overheating 
and fire.

Do not climb up on or sit on the unit. 

You may be injured if you fall or if the unit 
falls over.

Care should be taken when using the unit 
in a room with the following persons:

Infants, children, elderly people, and people 
not sensitive to humidity. 

Do not use in areas where chemicals are 
handled.

This will cause the unit deterioration due to 
chemicals and solvents dissolved in the air.

Do not put in places where water may splash onto the unit.

Water may enter the unit and degrade the insulation. It may cause an electric shock or fire.

Never insert your finger or other foreign objects into grills or openings. Take special care to warn 
children of these dangers.

It may cause electric shock or failure of appliance.

Do not place heavy object on the power 
cord and take care so that the cord is not 
compressed.

There is danger of fire or electric shock.

Do not cover the intake or exhaust 
openings with cloths or towels.

A lack of air flow can lead to overheating 
and fire.

Always insert the filters securely. Clean 
filter once every two weeks.

Operation without filters may cause failure.

If water enters the unit, turn the unit 
off and disconnect the power, contact a 
qualified service technician.

It may cause failure of appliance or accident

Do not place flower vases or other water container on top of the unit. 

Water may spill inside the unit, causing insulation failure and electrical shock or fire.

Place the unit on a level, sturdy section of the floor. 

If the unit falls over, it may cause water to spill and damage belongings, or cause electrical shock or fire.

SAFETY PRECAUTIONS

Summary of Contents for Dorai D16W

Page 1: ...ENG DORAI W Dorai D16W Dorai D20W User manual...

Page 2: ...ontrol panel and functions 12 Other features 13 PART 2 OPERATING THE UNIT 15 Identification of parts 15 Positioning the unit 15 When using the unit 16 Removing the collected water 17 PART 3 CARE AND M...

Page 3: ...s D Products of this type contains valuable elements it can be sold sprzedane on purchase of metals Throwing the device on wild exposes you to the risk of losing your health Dangerous substances from...

Page 4: ...d be paid attention by the user Otherwise operation error can cause damage to the product or other losses Notice Sign Never do this Always do this Do not exceed the rating of the power outlet or conne...

Page 5: ...places where water may splash onto the unit Water may enter the unit and degrade the insulation It may cause an electric shock or fire Never insert your finger or other foreign objects into grills or...

Page 6: ...Do not cover cord with throw rugs runners or similar coverings Do not route cord under furniture or appliances Arrange cord away from traffic area and where it will not be tripped over Do not open th...

Page 7: ...flames an operating gas appliance or an operating electric heater Do not pierce or burn Be aware that the refrigerants may not contain an odour Appliance should be installed operated and stored in a...

Page 8: ...cing 1 Checks to the area Prior to beginning work on systems containing flammable refrigerants safety checks are necessary to ensure that the risk of ignition is minimised For repair to the refrigerat...

Page 9: ...tinuestobevisibleandlegible Markingsandsignsthatareillegibleshallbecorrected Refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance which m...

Page 10: ...ntsbuttheuseofdetergentscontainingchlorineshallbeavoidedasthechlorine may react with the refrigerant and corrode the copper pipe work If a leak is suspected all naked flames shall be removed extinguis...

Page 11: ...ecovery of refrigerant Cylinders shall be complete with pressure relief valve and associated shut off valves in good working order The recovery equipment shall be in good working order with a set of i...

Page 12: ...normal 10 Mode pad Press to select the desired operation mode from Dehumidifying Dryer Continuous dehumidifying and Smart dehumidifying NOTE Dryer and Smart dehumidifying modes are optional 11 Up Down...

Page 13: ...elative Humidity Error Codes and Protection Codes AS Humidity sensor module error Unplug the unit and plug it back in If error repeats call for service ES Temperature sensor error Unplug the unit and...

Page 14: ...at any time or adjusting the timer setting to 0 0 will cancel the Auto Start Or Auto Stop feature When LED display window displays the code of P2 the Auto Start or Auto Stop feature will also be cance...

Page 15: ...little or no effect in drying an adjacent enclosed storage area such as a closet unless there is adequate circulation of air in and out of the area Do not use outdoors This dehumidifier is intended f...

Page 16: ...er in the bucket The unit may tip over and spill water NOTE Casters is optional 3 WHEN USING THE UNIT When first using the dehumidifier operate the unit continuously 24 hours This unit is designed to...

Page 17: ...do not touch any parts inside of the unit Doing so may damage the product Be sure to push the bucket gently all the way into the unit Banging the bucket against anything or failing to push it in secur...

Page 18: ...ose from the outlet and attach the rubber plug back to the drain outlet Make sure the water hose is lower than the drain hose outlet Select the desired humidity setting and fan speed on the unit for c...

Page 19: ...ldew and bacteria Partially fill the bucket with clean water and add a little mild detergent Swish it around in the bucket empty and rinse 3 Clean the air filter The air filter behind the front grille...

Page 20: ...kles of the filter first and then pat the bottom bukcle CAUTION DO NOT operate the dehumidifier without a filter because dirt and lint will clog it and reduce performance NOTE The cabinet and front ma...

Page 21: ...r back of the dehumidifier The humidity selector may not be set low enough Checkthatalldoors windowsandotheropeningsaresecurelyclosed Room temperature is too low below 5 C 41 F There is a kerosene hea...

Page 22: ...DORAI W Dehumidifier 22 User manual NOTES...

Page 23: ...DORAI W Dehumidifier 23 User manual NOTES...

Page 24: ...www rotenso pl email info rotenso pl Installer stamp...

Reviews: