background image

Dorai W - Dehumidifier

6

User manual

PART 1. SAFETY INFORMATION

 

 

CAUTION

•  This appliance can be used by children aged from 8 years and above and persons with reduced 

physical, sensory or mental capabilities or lack of experience and knowledge if they have been given 
supervision or instruction concerning use of the appliance in a safe way and understand the hazards 
involved. Children shall not play  with the appliance. Cleaning and user maintenance shall not be made 
by children.

•  If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly 

qualified persons in order to avoid a hazard.

•  The appliance shall be installed in accordance with national wiring regulations.
•  Contact the authorised service technician for repair or maintenance of this unit.
•  Do not use the socket if it is loose or damaged.
•  Do not operate your dehumidifier in a wet room such as a bathroom or laundry room.
•  Do not use this product for functions other than those described in this instruction manual.
•  If the device is knocked over during use, turn off the unit and unplug it from the main power supply 

immediately. Visually inspect the unit to ensure there is no damage. If you suspect the unit has been 
damaged, contact a technician or customer service for assistance.

•  In a thunderstorm, the power must be cut off to avoid damage to the machine due to lightning.
•  To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device.
•  Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do 

not route cord under furniture or appliances. Arrange cord away from traffic area and where it will not 
be tripped over.

•  Do not open the unit during operation.
•  When the air filter is to be removed, do not touch the metal parts of the unit.
•  Hold the plug by the head of the power plug when taking it out.

3. ELECTRICAL INFORMATION

1. The manufactures nameplate is located on the rear panel of the unit and contains electrical and other 

technical data specific to this unit.

2. Be sure the unit is properly grounded. To minimize shock and fire hazards, proper grounding is important. 

The power cord is equipped with a three-prong grounding plug for protection against shock hazards.

3. Your unit must be used in a properly grounded wall receptacle. If the wall receptacle you intend to use is not 

adequately grounded or protected by a time delay fuse or circuit breaker(the fuse or circuit breaker needed 
is determined by the maximum current of the unit. The maximum current is indicated on the nameplate 
located on unit), have a qualified electrician install the proper receptacle.

4. Ensure the receptacle is accessible after the unit installation.
5. Do not use extension cords or an adapter plugs with this unit. However, if it is necessary to use an extension 

cord, use an approved Dehumidifier extension cord only (available at most local hardware stores).

6. To avoid the possibility of personal injury, always disconnect the power supply to the unit, before installing 

and/or servicing.

7. All wiring must be performed strictly in accordance with the wiring diagram located on the middle baffle of 

the unit (behind the water bucket).

Summary of Contents for Dorai D10W

Page 1: ...ENG User manual DORAI W Dorai D10W Dorai D12W...

Page 2: ...ontrol panel and functions 12 Other features 13 PART 2 OPERATING THE UNIT 14 Identification of parts 14 Positioning the unit 14 When using the unit 15 Removing the collected water 16 PART 3 CARE AND M...

Page 3: ...ction you can pass the device without the cost B When you buy a new device the seller will accept the old device without any fees C Manufacturer will take the product from buyer produkt without chargi...

Page 4: ...ould be paid attention by the user Otherwise operation error can cause damage to the product or other losses Notice Sign Never do this Always do this Do not exceed the rating of the power outlet or co...

Page 5: ...in the air Do not put in places where water may splash onto the unit Water may enter the unit and degrade the insulation It may cause an electric shock or fire Never insert your finger or other forei...

Page 6: ...der carpeting Do not cover cord with throw rugs runners or similar coverings Do not route cord under furniture or appliances Arrange cord away from traffic area and where it will not be tripped over D...

Page 7: ...pen flames an operating gas appliance or an operating electric heater Do not pierce or burn Be aware that the refrigerants may not contain an odour Appliance should be installed operated and stored in...

Page 8: ...nformation on servicing 1 Checks to the area Prior to beginning work on systems containing flammable refrigerants safety checks are necessary to ensure that the risk of ignition is minimised For repai...

Page 9: ...the secondary circuit shall be checked for the presence of refrigerant Marking to the equipment continues to be visible and legible Markings and signs that are illegible shall be corrected Refrigerati...

Page 10: ...ion and is suitable for the refrigerant used Leak detection fluids are suitable for use with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react...

Page 11: ...e special cylinders for the recovery of refrigerant Cylinders shall be complete with pressure relief valve and associated shut off valves in good working order The recovery equipment shall be in good...

Page 12: ...ithin a range of 35 RH Relative Humidity to 85 RH Relative Humidity in 5 increments For damper air press the pad and set a higher percent value Down pad Humidity Set Control Pads The humidity level ca...

Page 13: ...humidity level please look right at the LED display window 2 OTHER FEATURES 1 Bucket Full Light Glows when the bucket is ready to be emptied or when the bucket is removed or not replaced in the proper...

Page 14: ...T A dehumidifier operating in a basement will have little or no effect in drying an adjacent enclosed storage area such as a closet unless there is adequate circulation of air in and out of the area D...

Page 15: ...move the unit with water in the bucket The unit may tip over and spill water NOTE Casters is optional 3 WHEN USING THE UNIT When first using the dehumidifier operate the unit continuously 24 hours Thi...

Page 16: ...ny parts inside of the unit Doing so may damage the product Be sure to push the bucket gently all the way into the unit Banging the bucket against anything or failing to push it in securely may cause...

Page 17: ...NOTE When the continuous drain feature is not being used remove the drain hose from the outlet and attach the rubber plug back to the drain outlet Make sure the water hose is lower than the drain hose...

Page 18: ...of mold mildew and bacteria Partially fill the bucket with clean water and add a little mild detergent Swish it around in the bucket empty and rinse 3 Clean the air filter The air filter behind the fr...

Page 19: ...kles of the filter first and then pat the bottom bukcle CAUTION DO NOT operate the dehumidifier without a filter because dirt and lint will clog it and reduce perfor mance NOTE The cabinet and front m...

Page 20: ...k of the dehumidifier The humidity selector may not be set low enough Check that all doors windows and other openings are securely closed Room temperature is too low below 5 C 41 F There is a kerosene...

Page 21: ...NOTES...

Page 22: ...NOTES...

Page 23: ...NOTES...

Page 24: ...www rotenso com email info rotenso com...

Reviews: