Rotec RTC.50-T User Manual Download Page 8

 

8

 

The

 

Control

 

Panel

 

The

 

control

 

panel

 

on

 

your

 

magnetic

 

drilling

 

machine

 

is

 

designed

 

for

 

maximum

 

operating

 

facility

 

and

 

safety.

 

 

1

 ‐ 

The

 

Magnet

 

Switch:

  

This

 

switch

 

is

 

used

 

to

 

switch

 

the

 

main

 

power

 

and

 

also

 

the

 

magnet

 

On

 

and

 

Off.

 

This

 

switch

 

is

 

included

 

on

 

every

 

Rotec

 

magnetic

 

drilling

 

machine

 

 

2

 ‐ 

The

 

On/Off

 

Switch:

  

This

 

switch

 

is

 

used

 

to

 

switch

 

the

 

motor

 

unit

 

On

 

and

 

Off

 

and

 

is

 

included

 

on

 

every

 

Rotec

 

Magnetic

 

Drilling

 

Machine

 

 

3

 ‐ 

The

 

Fuse

 

holder

 

with

 

Fuse:

  

This

 

Fuse

 

holder

 

is

 

included

 

on

 

every

 

Rotec

 

Magnetic

 

Drilling

 

Machine

 

and

 

holds

 

the

 

fuse

 

type

 

:

 

5x20,

 

F2A.

 

 

4

 ‐ 

The

 

Magnet

 

LED

 

Indicator:

  

This

 

LED

 

indicator

 

shows

 

the

 

generated

 

magnetic

 

force.

  

 

5

 ‐ 

The

 

L/R

 

Switch:

  

This

 

switch

 

controls

 

the

 

direction

 

of

 

the

 

motor

 

unit.

 

 

6

 ‐ 

The

 

Potentiometer:

  

This

 

controls

 

the

 

running

 

speed

 

of

 

the

 

motor

 

unit.

 

Note

 

that

 

a

 

lower

 

position

 

will

 

decrease

 

the

 

power

 

of

 

the

 

motor

 

unit.

 

 

Continuous

 

electronic

 

Torque

 

protection:

 

The

 

RTC.50T

 

is

 

equipped

 

with

 

a

 

all

time

 

electronic

 

torque

 

protection.

 

It

 

will

 

stop

 

the

 

motor

 

unit

 

when

 

it

 

gets

 

overloaded

 

in

 

any

 

rpm.

  

In

 

that

 

case

 

just

 

push

 

the

 

OFF

 

switch

 

to

 

reset

 

and

 

ON

 

switch

 

to

 

start

 

drilling

 

again.

  

Continuous

 

electronic

 

Temperature

 

protection

 

:

  

The

 

RTC.50T

 

is

 

equipped

 

with

 

a

 

all

time

 

electronic

 

temperature

 

protection.

 

If

 

the

 

temperature

 

of

 

the

 

motor

 

unit

 

runs

 

up

 

to

 

70

 

Degree

 

Celsius

 

the

 

motor

 

unit

 

will

 

stop.

 

After

 

a

 

few

 

minutes

 

it

 

can

 

be

 

started

 

again

 

and

 

we

 

recommend

 

to

 

let

 

the

 

motor

 

run

 

unloaded

 

with

 

the

 

electronic

 

speed

 

adjustment

 

set

 

on

 

100%

 

to

 

let

 

the

 

motor

 

unit

 

cool

 

down.

  

 

!!!

 

IMPORTANT

 

!!!

 

When

 

using

 

your

 

magnetic

 

drilling

 

machine

 

non

horizontal

 

or

 

upside

down

 

be

 

aware

 

that

 

no

 

oil,

 

drilling

 

compound

 

or

 

metal

 

chips

 

can

 

fall

 

into

 

the

 

motor

 

unit.

 

Rotec

 

accepts

 

no

 

responsibility

 

for

 

damage

 

done

 

to

 

your

 

machine

 

by

 

such

 

action

 

under

 

coverage

 

of

 

the

 

warranty.

 

 

 

Drilling

 

Now

 

that

 

you

 

have

 

read

 

the

 

explanatory

 

information

 

and

 

safety

 

recommendations

 

above,

 

you

 

are

 

ready

 

to

 

actually

 

start

 

drilling.

 

Follow

 

these

 

10

 

steps

 

for

 

best

 

drilling

 

result

 

:

 

Summary of Contents for RTC.50-T

Page 1: ...USER MANUAL TO REDUCE THE RISK OF INJURY USER MUST READ AND UNDERSTAND INSTRUCTION MANUAL RTC 50 T Magnetic Drilling Machine SERIAL NO _______________ DATE OF PURCHASE _____________...

Page 2: ...e motor unit page 7 4 The Magnetic Drilling Machine The Magnetic Base page 7 The Control Panel page 8 All time electronic protections page 8 Drilling page 9 5 Maintenance page 10 6 Spare parts Explode...

Page 3: ...machine with the safety chain 9 When changing a hole cutter the magnetic drilling machine must be disconnected from power supply 10 Clean the area around the machine regularly Keep the bottom of the m...

Page 4: ...g approved for the country or region it is to be used in The yellow green wire in the lead is the earth wire Never connect this to a pole under voltage All Rotec magnetic drilling machines are manufac...

Page 5: ...ng depth 55 mm increasing by 1 mm 538 xxx1 18 mm 50 mm Hole cutters with cutting depth 80 mm increasing by 1 mm 538 xxx2 18 mm 50 mm Hole cutters with cutting depth 110 mm increasing by 1 mm Rotec Har...

Page 6: ...g Rotec recommends the use of a drilling compound or paste like 901 4045 or 901 4046 4 Tool Assembly Morse Taper Assembly Mount the Morse Taper into your machine by pushing it firmly into the shaft ex...

Page 7: ...tachment force generated by the magnet depends on various factors Thickness of the material the magnet is placed on Paint or coating of the material the magnet is placed on Metal chips oil or other di...

Page 8: ...ue protection The RTC 50T is equipped with a all time electronic torque protection It will stop the motor unit when it gets overloaded in any rpm In that case just push the OFF switch to reset and ON...

Page 9: ...e Use the upper gear high for hole cutters up to 20 mm and the lower gear for hole cutters above 20mm The RTC 50 T have a fully electronic motor unit which measures its speed continuously to have the...

Page 10: ...uded wrench 8 The adjustment is done well when the motor unit can be turned to every possible position without falling down by its own weight Check the grease in the gearbox regularly and replace it i...

Page 11: ...tch 36 Control Unit Hi Lo 220v Control Unit Hi Lo 110v 37 Cable clamp 38 Motorunit 220v Motorunit 110v 39 Cable housing 40 Screw PKVZ4 8x35 51 Screw 3 9x60 52 Adaptor ring 22x0 2 53 Needle bearing 54...

Page 12: ...12...

Page 13: ...es it is recommended to provide the frame number of your machine when ordering spare parts This number can be found on front of machine at magnetic base and frame When you have any doubt when ordering...

Reviews: