WARNING  

Before attempting to lift any vehicle, be 

sure that:

A.  Vehicle individual axle weight does not exceed two lift 

columns combined capacity.

B.  Lift forks are in secure contact with vehicle tires.

C.  Adequate overhead clearance is provided to raise 

vehicle to desired height.

D.  Parking brake is released on vehicle.

E.  Adjustable forks must be equally spaced off centerline 

of lift carriage, and adjusted to properly accommodate 

the tire/wheel size.

F.  Ensure tires are properly inflated before lifting.  DO NOT 

exceed tire load rating when raising vehicle.

9.  To Raise Lift:

A.  Ensuring that the System Configuration Lock/Unlock 

light is green, press the Raise Button.  Raise the vehicle 

until vehicle tires clear the floor.

Check Fork Contact: Stop and check for secure fork contact 

with tires, at all columns.

B.  Continue to raise the vehicle to desired height.

NOTE: While cycling the lift, you may observe the individual 

columns slowing down and speeding up at various stages 

of travel. This is a normal characteristic of the lift leveling 

system.

Monitor the safety locks while raising the lift by listening for 

the mechanical lock clicking.

Do Not go under vehicle unless all tires are in secure 

contact with forks.  Lower lift and repeat vehicle and/or lift 

spotting and loading procedure if required.

C.  Press the Lower To Locks Button to lower columns onto 

the locking latches.

10.  While Using Lift: Avoid excessive rocking of vehicle 

while on the lift.

11.  Before Lowering Lift: Remove tool trays, safety stands, 

etc. from area.

10.To Lower Lift:

A.  Ensuring that the System Configuration Lock/Unlock 

light is green, press the Raise Button to raise lifts off the 

locks.

B.  Press the Lower Button to lower lift.  The Slow Lower 

Button (1/3 speed) can be used if desired.  Observe that 

all columns are lowering and vehicle remains level.

C.  Remain clear of forks and vehicle when lowering.  

Observe pinch point WARNING decals.

D.  Reset the parking brake.

E.  Move all lift units away from the vehicle to provide an 

unobstructed exit before removing the vehicle.

Summary of Contents for HydroLift MC62

Page 1: ...O N M A I N T E N A N C E Original Instructions Mobile Column Lift 24V DC Powered 4 Column Lift Capacity 24 800 kg 6 Column Lift Capacity 37 200 kg 6 200 kg per column IN161101N A IMPORTANT Reference...

Page 2: ...t heavy vehicles for maintenance cleaning or repair to optimum working height Operation is carried out with a mobile control panel Lifting and lowering the vehicle is carried out in jog mode Electroni...

Page 3: ...Battery Size 24 Frame Group 80 AH Capacity At 20 AH Rate Stud Terminals with Stainless Steel Wing nuts Battery wires are clearly marked labeled inside the unit itself Install tie down straps on batte...

Page 4: ...e is 10 5mm per meter side to side of vehicle and 21 0mm per meter front to rear of vehicle DO NOT use on a suspended floor structure without specific approval from structural engineer Ensure tires ar...

Page 5: ...enough to engage locks b Loosen bleed screw to release air from system c Close screw and repeat steps a and b until there is no air in the system and fluid runs clear Bleed Screw Do Not Exceed Torque...

Page 6: ...d in the safe use and operation of the lift using the manufacturer s operating instructions ALI SM 07 1 ALI Lifting it Right safety manual ALI ST 05 ALI Safety Tips card ANSI ALI ALOIM 2008 American N...

Page 7: ...interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful inte...

Page 8: ...was just placed The column will show Green when activated 5 Position next column at second wheel using loading instructions from step 3 6 Turn on second column Again using the Control Panel and the bu...

Page 9: ...9 Fig 3 Fig 4 Fig 2 Power Up Switch...

Page 10: ...olumns slowing down and speeding up at various stages of travel This is a normal characteristic of the lift leveling system Monitor the safety locks while raising the lift by listening for the mechani...

Page 11: ...open Power Unit Cover Pull lock open Pull the Manual Lowering Valve Button and the carriage will begin lowering C If lift is on locks slightly lift carriage until lock is free D Lower each carriage a...

Page 12: ...ed Red fast flash indicates a column with an error Operating Instruction Details Options Changing the System Configuration Columns may only be added to or removed from a system by unlocking the existi...

Page 13: ...THE VICINITY OF A LEAD ACID BATTERY IS DANGEROUS BATTERIES CONTAIN SULFURIC ACID AND PRODUCE EXPLOSIVE GASES A BATTERY EXPLOSION COULD RESULT IN LOSS OF EYESIGHT OR SERIOUS BURNS FOR THIS REASON IT IS...

Page 14: ...rriage for damage Monthly Check Emergency Stop Push the Emergency Stop button Columns should be inoperative with any emergency stop button depressed Monthly Lubrication 1 Lower lift check oil level in...

Page 15: ...ess the buttons below in exact order until the error is generated 1 Up button Error Check replace contactor 2 Slow lower Error Check replace small lowering valve 3 Lower to locks Error Check replace l...

Page 16: ...nnect switch is OFF if one is provided on the lift 3 The authorized lockout person operates the main energy isolation device removing power to the subject lift If this is a lockable device the authori...

Page 17: ...Charger Red Black Black 12V Battery 12V Battery Ground String Pot Radio Wireless 2SWLRQDO Control PCB Buzzer Slow Valve Lock Solenoid Fast Valve Contactors Red White Black Bat Voltage Monitor Black B...

Page 18: ...18 HYDRAULIC SCHEMATIC...

Page 19: ...19 NOTES...

Page 20: ...r for Genuine Rotary Replacement Parts See Literature Package for Parts Breakdown Rotary Lift Consolidated Haimen Co Ltd No 1388 East Xiushan Road Haimen Jiangsu Province China 226100 www vsg asia com...

Reviews: