request, option 2:
010000003C
01 - Command
0000003C – time in seconds (60 s)
Response is not provided.
0x02 - Change the time of the next connection only
request, option 1:
01003C
01 - Command
003C - time in seconds (60 s)
request, option 2:
010000003C
01 - Command
0000003C - time in seconds (60 s)
Response is not provided.
0x03 - Change polling interval permanently (saved after restart)
request, option 1:
01003C
01 - Command
003C - time in seconds (60 s)
request, option 2:
010000003C
01 - Command
0000003C - time in seconds (60 s)
Response:
21030300
21 – package type (0x21 - Response)
03 – Request port
03 - Command
00 - Result (0 - success, 1 - error)
The switching device is supplied with built-in firmware that enables the switching device to
operate with the characteristics specified in this document. The switching device is
programmed using a special input for the programmer.
The switching device is configured using special control commands that are sent to the
switching device in LoRaWAN network.
ROSSMA IIOT-AMS switching devices shall be stored in the factory package in heated rooms at
temperature from 5 ° С to 40 ° С and with relative humidity not more than 85%.
The switching devices can be transported in covered cargo compartments of all types for any
distances at temperature from -40 ° С to 85 ° С.
.
5.
STORAGE AND TRANSPORTATION RULES