Limited Warranty 

The full ROSSLARE Limited Warranty Statement is available in the Quick 

Links section on the ROSSLARE website a

www.rosslaresecurity.com

Rosslare considers any use of this product as agreement to the 
Warranty Terms even if you do not review them. 

Contact Information

Asia Pacific, Middle East, Africa 

Rosslare Enterprises Ltd. 
Kowloon Bay, Hong Kong 

Tel:  +852 2795-5630 
Fax:  +852 2795-1508 
[email protected] 

 

United States and Canada 

Rosslare Security Products, Inc. 
Southlake, TX, USA 76092 
Toll Free: +1-866-632-1101 

Local: +1-817-305-0006 
Fax:  +1-817-305-0069 
[email protected] 
 

Europe 

Rosslare Israel Ltd. 
Rosh HaAyin, Israel 48091 
Tel:  +972 3 938-6838 

Fax:  +972 3 938-6830 
[email protected] 
 

Latin America 

Rosslare Latin America 
Buenos Aires, Argentina 

Tel:  +54-11-4001-3104 
[email protected] 
 

China 

Rosslare Electronics (Shenzhen) Ltd. 
Shenzhen, China 
Tel:  +86 755 8610 6842 
Fax:  +86 755 8610 6101 

[email protected] 
 

India 

Rosslare Electronics India Pvt Ltd. 
Tel/Fax:  91 20 40147830 

Mobile:  91 9975768824 
[email protected] 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

www.rosslaresecurity.com 

 

  

  

  

 

 

070

6-

096

02

31+

02

 

Summary of Contents for MD-D02

Page 1: ...en Normally Closed Supervised with one resistor three states normally open or normally closed Supervised with two resistors four states Normally Open or Normally Closed 2 3 7BPhysical Characteristics Dimensions L x W x D 100 x 75 9 x 32 5 mm 3 94 x 2 99 x 1 28 in Weight 98 2 g 3 46 oz 2 4 8BReader Characteristics Reader Output Voltage 12 VDC Max Reader Current 245 mA LED Control Output Open collec...

Page 2: ...pen supervised input connection with double resistor Figure 6 Normally Open Supervised Inputs with Double Resistor Normally Open Supervised inputs with two resistors must be connected with an 8 2K resistor in parallel and a 2 2K resistor in series to the input switch contacts Figure 7 shows the normally closed supervised input connection with single resistor Figure 7 Normally Closed Supervised Inp...

Page 3: ...r specific details Readers connected through an MD D02 are recognized as Reader 3 and Reader 4 in the software system Figure 9 and Figure 10 show the wiring for Readers 3 and 4 respectively Figure 9 Wiring for Reader 3 Figure 10 Wiring for Reader 4 5 Using the MD D02 5 1 Operating the MD D02 The access control panel detects the MD D02 expansion board when it powers up When defining the panel in th...

Page 4: ...lare Security Products Inc Southlake TX USA 76092 Toll Free 1 866 632 1101 Local 1 817 305 0006 Fax 1 817 305 0069 support na rosslaresecurity com Europe Rosslare Israel Ltd Rosh HaAyin Israel 48091 Tel 972 3 938 6838 Fax 972 3 938 6830 support eu rosslaresecurity com Latin America Rosslare Latin America Buenos Aires Argentina Tel 54 11 4001 3104 support la rosslaresecurity com China Rosslare Elec...

Reviews: