Operating the HLX-24
12
HLX-24 User Manual
If Silent Exit is active, the Exit Time is doubled for that exit period only, but
does not exceed 255 seconds.
During Home arming, the system ignores all interior zones as well as the
predefined delay zones.
3.3.7
Exit Restart
When this feature is enabled, an Exit Restart delay occurs on the second zone
opening within the same zone and the Exit Delay time is doubled. If it is
disabled, the same zone may be opened several times while in the Exit Delay
countdown.
3.4
Disarm Mode
When disarmed, the HLX-24 system is in Standby mode. Alarms trigger only
for panic, fire, 24-hour audible, and silent conditions.
In this state, the system continuously checks zone status and holds the Ready
status parameter. This parameter determines whether the system is ready to be
armed. The system becomes Ready to Arm when zones are either closed or
bypassed.
To disarm the system:
1.
Press the
Disarm
key.
2.
Enter your user code.
•
If the user disarms the system during Exit/Entry mode, the progress
annonciation is silenced on the first keystroke of the user code. If the code
is invalid, the progress annonciation resumes.
•
If the user disarms the system during the Abort time, the alarm
announciation is silenced on the first keystroke of the user code. If the code
is invalid, the alarm resumes.
•
If the user disarms the system by remote control, a squawk
acknowledgement is produced once in the local sounders.
3.4.1
Entry Delay
An entry delay enables the user to enter the site through a specified door
(determined as a delay zone) using a predetermined path, without setting off
an alarm. The entry delay is set at 30 seconds by default.
After entry, the user must disarm the system before the entry delay expires. A
progress annunciation of slow-rate warning beeps sound upon detection of
the specified zone. The system counts down the last 10 seconds of the delay
indication if enabled or the warning beeps become faster.