![Rosslare AY-Z12 Installation Manual Download Page 6](http://html.mh-extra.com/html/rosslare/ay-z12/ay-z12_installation-manual_1489195006.webp)
Technical Specifications
AY-Z12 Installation Manual
Page 5
2.
Technical Specifications
Electrical Characteristics
Power Supply Type
Linear type - recommended
Operating Voltage Range 10 - 16VDC
Absolute Maximum
(non-operating)
18VDC
Input Current
Standby: 280mA
Read: 330mA
Tamper Output
Open collector, active low, max.
sink current 30mA
Maximum Cable Distance
to Controller
500 ft (150 meters)
Card Read Distance
Weigand 26 output format with a
23.6" (60 cm) maximum read
range*
Environmental Characteristics
Operating Temp. Range
-22°F to 145° F (-30°C to 63°C)
Operating Humidity
0 – 95% (non-condensing)
Suitable for outdoor use (IP54)
Dimensions
Height x Width x Depth
11.81" x 11.81" x 1.0"
300mm x 300mm x 25.4 mm
Weight
2.35 Lbs. (1066g)
* Measured using Rosslare Proximity Card AT-R14 or equivalent. Range also
depends on electrical environment and proximity to metal.