Rosslare AY-x20 Series Installation Manual Download Page 2

 

3.

 

Installation 

3.1

 

Installation Kit 

The installation kit consists of the following items to be used during 

the installation procedure: 

 

One mounting template 

 

Two pan head screws and wall plugs 

 

One L-shaped security screw tool 

 

One security screw 

3.2

 

Mounting the AY-x20 Reader 

Before mounting, you should determine the best location for the 

reader. 
To mount the reader: 
1.

 

Peel off the back of the self-adhesive mounting label template and 
place it at the required mounting location. 

2.

 

Using the template as a guide, drill two holes (sizes indicated on 
the template) used for mounting the reader onto the surface, 

3.

 

Insert a suitable wall plug into each hole. 

4.

 

Drill a 10-mm (7/16”) hole for the cable. If mounting on metal, 
place a grommet or electrical tape around the edge of the hole. 

5.

 

Wire the reader to the controller as described in Section 

 4

. A linear 

type power supply is recommended. 

6.

 

Remove the reader's snap-off front cover to reveal the two screw 

holes (see Figure 2 ). 

Figure 2: Removing the Top Cover 

 

7.

 

Align the two holes of the reader with those drilled in the wall and 

firmly attach the reader to the wall with two screws, whose size is 

indicated on the template. 

8.

 

Relocate the front cover onto the reader. 

 

The reader can also be mounted using strong epoxy glue. After 

application, the reader should be firmly held in place until the 
glue dries. 

 

 

Card readers are to be used with control panels whose power 
supply is UL Listed Class 2 or equivalent. 

4.

 

Wiring 

The AY-x20 is supplied with a 10-conductor 18” pigtail. 
To connect the reader to the controller: 
9.

 

Prepare the reader cable by cutting its jacket back about 3 cm 
(1¼") and strip the insulation from the wires about 1.2 cm (½"). 

10.

 

Prepare the controller cable by cutting its jacket back 3 cm (1¼") 

and strip the insulation from the wires about 1.2 cm (½"). 

11.

 

Splice the reader’s pigtail wires to the corresponding controller 

wires (as indicated in Table 1) and cover each joint with insulating 
tape. 

Table 1: Wiring 

Wire Color 

Wiegand 26-Bit 
Output Mode 

Clock & Data 
Output Mode 

Serial (RS-232) 
Output Mode 

Red 

+DC 

+DC 

+DC 

Black 

Ground 

Ground 

Ground 

Green 

Data 0 

Data 

RS-232 

White 

Data 1 

Clock 

Orange 

Green LED 

Green LED 

Green LED 

Brown 

Red LED 

Red LED 

Red LED 

Yellow 

Buzzer 

Buzzer 

Buzzer 

Blue 

Hold 

Hold 

Hold 

Purple 

Tamper 

Tamper 

Tamper 

Grey 

Open Input 

Connected to GND  Connect to +DC 

12.

 

If the tamper output is being utilized, connect the purple wire to 

the correct input on the controller. 

13.

 

Trim and cover all unused conductors. 

 

 

The individual wires from the reader are color-coded according the 
Wiegand standard. 

 

When using a separate power supply for the reader, this supply 
and that of the controller must have a common ground. 

 

The reader’s cable shield wire should be preferably attached to an 
earth ground, or a signal ground connection at the panel, or 

power supply end of the cable. This configuration is best for 
shielding the reader cable from external interference 

 

5.

 

Operation Instructions 

5.1

 

Testing 

Once the reader is wired to a power supply and to the controller, you 
should test the reader. 
To test the reader: 
1.

 

Power up the reader. 
The LED and beeper activate one time. This indicates that the 

reader is working properly. 

2.

 

Present the appropriate type of proximity card to the reader. 

The LED momentarily flashes green and a short beep is emitted 

indicating that the card was read properly by the reader. 
After the card data is processed by the controller, the controller 

can then turn the LED green. Refer to the controller description of 
the LED operation if the reader LED is controlled by the controller. 

Summary of Contents for AY-x20 Series

Page 1: ...mum 55 mA Read Range 10 cm 3 94 in 12 cm 4 72 in 8 cm 3 15 in LED Control Input Dry Contact N O Tamper Output Open collector active low max sink current 16 mA Maximum Cable Distance to Controller 150 m 500 ft RF Modulation ASK 125 KHz Bit Rate 106 KHz All input voltages should be limited to 1 A maximum For VAC the voltage range is peak to peak Measured using a Rosslare proximity card or equivalent...

Page 2: ...m 10 Prepare the controller cable by cutting its jacket back 3 cm 1 and strip the insulation from the wires about 1 2 cm 11 Splice the reader s pigtail wires to the corresponding controller wires as indicated in Table 1 and cover each joint with insulating tape Table 1 Wiring Wire Color Wiegand 26 Bit Output Mode Clock Data Output Mode Serial RS 232 Output Mode Red DC DC DC Black Ground Ground Gro...

Page 3: ...wire is grounded the LED is red When both the brown and orange wires are grounded the LED is amber 5 4 Buzzer Control If the buzzer control wire yellow is not used open the buzzer beeps only when a card is read successfully The buzzer can also be controlled using the yellow wire When the yellow wire is grounded the buzzer sounds 5 5 Hold Control The reading of cards can be disabled using the hold ...

Page 4: ...rope Rosslare Israel Ltd Rosh HaAyin Israel Tel 972 3 938 6838 Fax 972 3 938 6830 support eu rosslaresecurity com Latin America Rosslare Latin America Buenos Aires Argentina Tel 54 11 4001 3104 support la rosslaresecurity com China Rosslare Electronics Shenzhen Ltd Shenzhen China Tel 86 755 8610 6842 Fax 86 755 8610 6101 support cn rosslaresecurity com Asia Pacific Middle East Africa Rosslare Ente...

Reviews: