background image

Limited Warranty

 

 

AY-E20 Instruction Manual 

Page 12 

Exclusions and Limitations  

ROSSLARE shall not be responsible or liable for any damage or loss resulting from the 
operation or performance of any Product or any systems in which a Product is 
incorporated. This warranty shall not extend to any ancillary equipment not furnished by 
ROSSLARE, which is attached to or used in conjunction with a Product, nor to any Product 
that is used with any ancillary equipment, which is not furnished by ROSSLARE. 
This warranty does not cover expenses incurred in the transportation, freight cost to the 
repair center, removal or reinstallation of the product, whether or not proven defective.  
Specifically excluded from this warranty are any failures resulting from Customer's 
improper testing, operation, installation, or damage resulting from use of the Product in 
other than its normal and customary manner, or any maintenance, modification, alteration, 
or adjustment or any type of abuse, neglect, accident, misuse,  improper operation, normal 
wear, defects or damage due to lightning or other electrical discharge. This warranty does 
not cover repair or replacement where normal use has exhausted the life of a part or 
instrument, or any modification or abuse of, or tampering with, the Product if Product 
disassembled or repaired in such a manner as to adversely affect performance or prevent 
adequate inspection and testing to verify any warranty claim. 
ROSSLARE does not warrant the installation, maintenance, or service of the Product.  
Service life of the product is dependent upon the care it receives and the conditions under 
which it has to operate.  
In no event shall Rosslare be liable for incidental or consequential damages.  
 

Limited Warranty Terms  

THIS WARRANTY SETS FORTH THE FULL EXTENT OF ROSSLARE ENTERPRISES LTD

.

 AND 

IT

S SUBSIDIARY

'

S WARRANTY

 

THE TERMS OF THIS WARRANTY MAY NOT BE VARIED BY ANY PERSON

,

 WHETHER OR 

NOT PURPORTING TO REPRESENT OR ACT ON BEHALF OF ROSSLARE

.

 

 

THIS LIMITED WARRANTY IS PROVIDED IN LIEU OF ALL OTHER WARRANTIES

.

 ALL OTHER 

WARRANTIES EXPRESSED OR IMPLIED

,

 INCLUDING WITHOUT LIMITATION

,

 IMPLIED 

WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE

,

 ARE 

SPECIFICALLY EXCLUDED

IN NO EVENT SHALL ROSSLARE BE LIABLE FOR DAMAGES IN EXCESS OF THE 

PURCHASE PRICE OF THE PRODUCT

,

 OR FOR ANY OTHER INCIDENTAL

,

 

CONSEQUENTIAL OR SPECIAL DAMAGES

,

 INCLUDING BUT NOT LIMITED TO LOSS OF 

USE

,

 LOSS OF TIME

,

 COMMERCIAL LOSS

,

 INCONVENIENCE

,

 AND LOSS OF PROFITS

,

 

ARISING OUT OF THE INSTALLATION

,

 USE

,

 OR INABILITY TO USE SUCH PRODUCT

,

 TO 

THE FULLEST EXTENT THAT ANY SUCH LOSS OR DAMAGE MAY BE DISCLAIMED BY LAW

THIS WARRANTY SHALL BECOME NULL AND VOID IN THE EVENT OF A VIOLATION OF THE 

PROVISIONS OF THIS LIMITED WARRANTY

 

Summary of Contents for AY-E20

Page 1: ...AY E20 Ultra slim Vandal Resistant Multi format Proximity Reader Instruction Manual March 2008 ...

Page 2: ......

Page 3: ...1 Key Features 5 3 Installation 6 3 1 Mounting the AY E20 6 4 Wiring Instructions 8 4 1 Wiring the AY E20 8 5 Operational Instructions 9 5 1 Testing the AY E20 and Card Reading 9 5 2 Card Transmission Format Selection 9 5 3 Tri Color LED Color Control 10 5 4 Buzzer Control 10 5 5 Card Read Hold Control 10 5 6 Tamper Output 10 Appendix A Limited Warranty 11 Appendix B Technical Support 13 ...

Page 4: ...wiring operating instructions and warranty details for the AY E20 reader 1 2 Box Content Before beginning verify that all of the following is in the box If anything is missing please report the discrepancy to your nearest Rosslare office One AY E20 unit Installation kit and mounting template Installation and operating instruction 1 3 Ancillary Equipment The following equipment is required to compl...

Page 5: ...ctor active low 16mA max sink current Cable distance to host controller Up to 500ft 150 meters using an 18AWG cable Proximity card read range 1 37inch 3 5cm Proximity card modulation ASK at 125 KHz Proximity card compatibility EM cards Card Transmit format 26 bit Wiegand Clock Data or Serial RS232 LED indicators One tri colored LED Environmental Characteristics Operating temp range 25 to 145 F 31 ...

Page 6: ...rical environment and proximity to metal 2 1 Key Features The key features for the AY E20 are Ultra Slim Flush mount design on flat surface Fully potted waterproof construction for outdoor use Built In 125 KHz ASK EM proximity card reader Selectable Card Transmission Formats 26 Bit Wiegand Clock Data or Serial RS 232 output Optical back tamper sensor Bi Color LED control Buzzer control Card read h...

Page 7: ... height To mount the AY E20 perform the following 1 For wall mounting use the included mounting template as a guide for drilling holes and mounting screws See figure 1 2 Drill a hole for the cable If mounting on metal place a grommet or electrical tape around the edge of the hole 3 Route the interface cable from the AY E20 to the Controller Figure 1 Drilling Mounting Template ...

Page 8: ...Gang Box mounting no drilling is necessary Simply screw the AY E20 to its mounting location or US gang box Note A linear type power supply is recommended Card readers are to be used with control panels whose power supply is UL Listed Class 2 or equivalent ...

Page 9: ... 3 Splice the unit s pigtail wires to the corresponding controller wires and cover each connection Refer to the wire color table below Wire Color Weigand Output Mode Clock Data Output Mode Serial RS232 Output Mode Red DC DC DC Black Ground Ground Ground Green Data 0 Data Tx RS 232 White Data 1 Clock Orange Green LED Green LED Green LED Brown Red LED Red LED Red LED Yellow Buzzer Buzzer Buzzer Blue...

Page 10: ...0 is working properly 2 Present the appropriate type of proximity card to the AY E20 The LED will momentarily flash green and a short beep will be emitted This indicates that the card was read properly by the AY E20 3 Once the card s data has been processed by the Controller the Controller can then switch the LED on the AY E20 to green Refer to the relevant Controller instruction manual for more i...

Page 11: ...4 Buzzer Control The Buzzer can be controlled using the yellow wire To control the Buzzer perform one of the following If the yellow wire is held to ground the buzzer will sound If the yellow wire is not used open the buzzer will beep only when a card is read successfully 5 5 Card Read Hold Control The reading of cards can be disabled using the blue wire To control the reading of cards perform one...

Page 12: ...his warranty Unless otherwise requested by ROSSLARE ENTERPRISES LTD AND OR SUBSIDIARIES representative return of the failed product s is not immediately required If ROSSLARE has not contacted the Customer within a sixty 60 day holding period following the delivery of the warranty claim Customer will not be required to return the failed product s All returned Product s as may be requested at ROSSLA...

Page 13: ...e Product if Product disassembled or repaired in such a manner as to adversely affect performance or prevent adequate inspection and testing to verify any warranty claim ROSSLARE does not warrant the installation maintenance or service of the Product Service life of the product is dependent upon the care it receives and the conditions under which it has to operate In no event shall Rosslare be lia...

Page 14: ...States and Canada 1600 Hart Court Suite 103 Southlake TX USA 76092 Toll Free 1 866 632 1101 Local 1 817 305 0006 Fax 1 817 305 0069 E mail support na rosslaresecurity com Europe Global Technical Support Training Center HaMelecha 22 Rosh HaAyin Israel 48091 Tel 972 3 938 6838 Fax 972 3 938 6830 E mail support eu rosslaresecurity com South America Pringles 868 1640 Martinez Buenos Aires Argentina Te...

Page 15: ......

Page 16: ...0706 0960225 01 www rosslaresecurity com ...

Reviews: