Rosslare AC-425-B Installation And User Manual Download Page 34

AC-425x-B Hardware Settings 

34 

AC-425x-B Hardware Installation and User Manual 

5.4

 

AC-425x-B Panel Address 

The last five DIP switches are used to set the binary code of the access control panel internal 
network address. The default access control panel address is “1”. 

 

For successful communications, the DIP switch must match the address set in the AxTraxNG 
software. 

Table 4 displays the 32 address settings available: 

Summary of Contents for AC-425-B

Page 1: ...AC 425x B Series Expandable 4 Reader Networked Access Control Panel Hardware Installation and User Guide Models AC 425 B AC 425 DIN AC 425IP B AC 425IP DIN ...

Page 2: ...al property rights covering the subject matter in this manual TEXTS IMAGES AND ILLUSTRATIONS INCLUDING THEIR ARRANGEMENT IN THIS DOCUMENT ARE SUBJECT TO THE PROTECTION OF COPYRIGHT LAWS AND OTHER LEGAL RIGHTS WORLDWIDE THEIR USE REPRODUCTION AND TRANSMITTAL TO THIRD PARTIES WITHOUT EXPRESS WRITTEN PERMISSION MAY RESULT IN LEGAL PROCEEDINGS The furnishing of this manual to any party does not give t...

Page 3: ...ervised Inputs 16 3 3 Outputs Wiring 16 3 4 Power Supply 17 3 5 AC 425x B Wiring Communications 19 3 6 Readers 19 3 7 MD IO84B 20 3 8 MD D04B 20 4 Input and Output Connections 21 4 1 Input Types 21 4 1 1 Normally Open Input Connection 21 4 1 2 Normally Closed Input Connection 22 4 1 3 Normally Open Supervised Single EOL Resistor Input Connection 22 4 1 4 Normally Open Supervised Double EOL Resisto...

Page 4: ...ch Configuration 30 5 2 AC 425x B Panel Baud Rate 31 5 3 AC 425x B Panel Type 31 5 4 AC 425x B Panel Address 34 6 Communications 37 6 1 Serial Network Connection 37 6 1 1 RS 232 Connection to the Computer 37 6 1 2 RS 485 Connection to the Computer 38 6 1 3 Daisy Chaining 39 6 2 TCP IP Network Connection 40 6 2 1 LAN and WAN Requirements 40 6 2 2 LAN and WAN Requirements 41 A Declaration of Conform...

Page 5: ... Figure 10 Normally Open Input Connection 22 Figure 11 Normally Closed Input Connection 22 Figure 12 Normally Open Supervised Input Single Resistor 23 Figure 13 Normally Open Supervised Input Double Resistor 23 Figure 14 Normally Closed Supervised Input Single Resistor 24 Figure 15 Normally Closed Supervised Input Double Resistor 25 Figure 16 DIP Switches 30 Figure 17 RS 232 Panel Connection to PC...

Page 6: ...Hardware Installation and User Manual List of Tables Table 1 DIP Switches and Their Functions 30 Table 2 Switch Baud Rates 31 Table 3 Possible Hardware Settings 31 Table 4 Available Panel Addresses 35 Table 5 RS 232 Connection 38 ...

Page 7: ...uture options Therefore not all functions described in this manual may be available in the specific system and or product configuration you purchased Incorrect operation or installation or failure of the user to effectively maintain the system relieves the manufacturer and seller from all or any responsibility for consequent non compliance damage or injury The text images and graphics contained in...

Page 8: ...pports TCP IP connection Driven by Rosslare s powerful flexible and easy to use AxTraxNG software the system provides an ideal modular and expandable solution for commercial and institutional needs It provides seamless integration with Rosslare s range of RFID proximity PIN Proximity PIN smartcard and biometric readers with Rosslare s selection of RFID credentials The AC 425x B is ready for instal...

Page 9: ...e system is custom designed to set up manage and supervise all aspects of an access panel network It offers the following capabilities Parameter Value Users capacity 30 000 Unauthorized users 30 000 Access groups 30 000 Number of panels in system 1023 Number of doors in system 8184 These options are software and firmware dependent and may change in later releases or revisions ...

Page 10: ...n to a range of advanced control features 1 1 2 Configurable Links The system s configurable links model makes it possible to trigger any chosen output automatically or report a configurable alarm based on a selected input This allows easy integration with other access systems such as intruder alarms CCTV systems and elevator controls AxTraxNG can also define a selected set of operations which are...

Page 11: ...Technical Specifications AC 425x B Hardware Installation and User Manual 11 2 Technical Specifications 2 1 AC 425x DIN ...

Page 12: ...er 245 mA LED control output and Tamper Input Visual Indicators 11 LEDs for outputs and communication status Audio Sounder output for use with compatible speakers provide chime bell and siren signals Battery Standby Time 3 hours with a 12 V 7 Ah lead acid battery Communication Characteristics RS 485 RS 232 RS 485 or optional RS 232 RS 485 connection by terminal block or MD 14U connector RS 232 con...

Page 13: ...M 10 Input Power 15 VDC 4 A to the power management board Output Power Two PTC fused outputs each provides 13 8 VDC 2 A One output for controller and readers One output for locks Battery Charger 13 8 VDC 300 mA for 12 VDC 7 Ah Lead Acid Battery Speaker 0 5 Watt 8 Ohm Light Bar 0 3 Watt for LED light Environmental Characteristics Operating Temperature Range 0 C to 49 C 32 F to 120 F Operating Humid...

Page 14: ...rs with MD D04B The panels connect together in a network and are controlled by a central server computer running the AxTraxNG software system Figure 2 shows an example setup for a network of AC 425x B access control panels Figure 2 Sample AC 425x B Configuration Bushings are needed for any conductors leaving the enclosure through the provided openings ...

Page 15: ... 425x B Hardware Installation and User Manual 15 3 1 Inputs Wiring Non Supervised Inputs Figure 3 presents a detailed view of the non supervised inputs and their connection options Figure 3 Inputs Wiring Non supervised Inputs ...

Page 16: ...d inputs resistors should be placed on the input switch and not on the terminal block For more details refer to Chapter 4 3 3 Outputs Wiring Figure 4 and Figure 5 illustrate wiring for two main types of 12 VDC electrical release mechanisms Other electrical devices can be switched using the voltage free relay contacts Figure 4 Door Lock Failed Close ...

Page 17: ...ement board and the AC 425x B Make sure the connection polarity is correct to and to Connect the power to the input power terminals of the control panel It is recommended to add a 12 VDC lead acid backup battery requires the ME 1015 Power Management Enclosure to have uninterrupted operation in case main power supply fails A 12 V 7 AH battery provides 3 hours of backup operation ...

Page 18: ...AC 425x B Panel Setup 18 AC 425x B Hardware Installation and User Manual Figure 6 Wiring Between PM 10 and AC 425x B ...

Page 19: ...ions Figure 7 AC 425x B Wiring Communications 3 6 Readers Proximity and keypad readers are supplied with a limited cable The color of the cable cover represents the cable s function according to Wiegand standards Figure 8 When extending the cable distance be careful with the color of the cable cover Refer to the reader specifications for the maximum cable length typically 150 m with an 18 AWG cabl...

Page 20: ... s expansion slot as marked in red in Figure 9 Figure 9 Connector Location for MD IO84B or MD D04B Expansions For more information see the MD IO84B Installation and User Guide 3 8 MD D04B The MD D04B is an optional reader expansion board that adds 4 readers 4 relay outputs and 4 supervised inputs to the access control panel Attach the MD D04B to the AC 425x B s expansion slot as marked in red in F...

Page 21: ...nputs Use the AxTraxNG system to configure each input separately Non supervised inputs have two states Normal Abnormal Supervised inputs have three states Normal Abnormal Trouble The Trouble state is caused by either tampering with the input circuit or by faulty hardware installation Once an input is configured as a supervised input add a resistor of 2 2 kΩ of 8 2 kΩ or both on the input circuit S...

Page 22: ...d Normal State Loop resistance 0 short circuit Switch Open Abnormal State Loop resistance Infinite open circuit Figure 11 Normally Closed Input Connection 4 1 3 Normally Open Supervised Single EOL Resistor Input Connection Connect an 8 2 kΩ resistor in parallel to the input switch contacts A Normally Open Supervised Input has 3 states Switch Open Normal State Loop resistance 8 2 kΩ Switch Closed A...

Page 23: ...rvised Double EOL Resistor Input Connection Connect a 2 2 kΩ resistor in series to the input switch contacts Connect an 8 2 kΩ resistor parallel to the input switch contacts A Normally Open Supervised Input has 3 states Switch Open Normal State Loop resistance 10 4 kΩ Switch Closed Abnormal State Loop resistance 2 2 kΩ Open circuit infinite loop resistance or short circuit 0 resistance across inpu...

Page 24: ...rcuit across input terminals Trouble State Loop resistance 0 short circuit Figure 14 Normally Closed Supervised Input Single Resistor 4 1 6 Normally Closed Supervised Double EOL Resistor Input Connection Connect a 2 2 kΩ resistor in series to the input switch contacts Connect an 8 2 kΩ resistor parallel to the input switch contacts A Normally Closed Supervised Input has 3 states Switch Closed Norm...

Page 25: ...that is located inside the premises The push button is generally located in an easy to access position and opens a door without reading a proximity card or PIN code Scenario Setting Two readers per door Door 1 IN 1 Door 2 IN 2 One reader per door Door 1 IN 1 Door 2 IN 2 Door 3 IN 3 Door 4 IN 4 REX input functions when using MD D04B Scenario Setting Two readers per door Door 1 IN1 Door 2 IN2 Door 5...

Page 26: ...Dedicated Input functions when using MD D04B Scenario Setting Two readers per door Door 1 IN3 Door 2 IN4 Door 3 IN7 Door 4 IN8 4 2 3 General Purpose Inputs These are free inputs that can be used for various functions This function is only available with the MD IO84B expansion The following should be defined Scenario Setting Single door controller Door 1 IN 2 Door 1 IN 2A Double door controller no ...

Page 27: ...s per door Door 1 OUT 1 Door 2 OUT 2 One reader per door Door 1 OUT 1 Door 2 OUT 2 Door 3 OUT 3 Door 4 OUT 4 Door outputs when using MD D04B Scenario Setting Two readers per door Door 1 OUT 1 Door 2 OUT 2 Door 3 OUT 5 Door 4 OUT 6 One reader per door Door 1 OUT 1 Door 2 OUT 2 Door 3 OUT 3 Door 4 OUT 4 Door 5 OUT 5 Door 6 OUT 6 Door 7 OUT 7 Door 8 OUT 8 The output can sink current from any power su...

Page 28: ...io Setting Two readers per door Door 1 Reader 1 IN OUT Door 1 Reader 3 IN OUT Door 2 Reader 2 IN OUT Door 2 Reader 4 IN OUT One readers per door Door 1 Reader 1 IN OUT Door 2 Reader 2 IN OUT Door 3 Reader 3 IN OUT Door 4 Reader 4 IN OUT When using the MD D04B the following should be defined Scenario Setting Two readers per door Door 1 Reader 1 IN OUT Door 1 Reader 3 IN OUT Door 2 Reader 2 IN OUT D...

Page 29: ...eader s tamper output connects to the access control panel s Reader Tamper input If the reader is interfered with an alarm can be generated The panel s Reader G LED output activates the reader s green LED input when operating in Card and PIN secure mode While this mode is in force users must enter a PIN on the keypad immediately after entering the card The controller activates the LED control for ...

Page 30: ... 1 The panel s communication baud rate 2 3 The panel type defines the number of readers for each door one or two readers per door This also affects the number of doors controlled by the panel 4 The access control panel s RS 485 network address 5 6 7 8 Power down the access control panel before changing the DIP switch settings After changes have been made restart the panel The new settings are auto...

Page 31: ... door or a panel with two readers per each door This DIP switch setting influences the number of readers per door in the panel The default AC 425x B panel setting is for two readers per each door Off Defines using two readers for each door Panel controls two or four doors when MD D04B is installed On Using one reader for each door Panel controls four doors or eight doors when MD D04B installed Sel...

Page 32: ...Door2 Lock output OUT 2 Door3 Lock output OUT 3 Door4 Lock output OUT 4 Inputs Door1 Request to exit IN 1 Door2 Request to exit IN 2 Door3 Request to exit IN 3 Door4 Request to exit IN 4 Readers Reader1 Door1 IN OUT Reader2 Door2 IN OUT Reader3 Door3 IN OUT Reader4 Door4 IN OUT Two readers per door with 8 readers MD D04B Outputs Door1 Lock output OUT 1 Door2 Lock output OUT 2 Door3 Lock output OUT...

Page 33: ...r2 Lock output OUT 2 Door3 Lock output OUT 3 Door4 Lock output OUT 4 Door5 Lock output OUT 5 Door6 Lock output OUT 6 Door7 Lock output OUT 7 Door8 Lock output OUT 8 Inputs Door1 Request to exit IN 1 Door2 Request to exit IN 2 Door3 Request to exit IN 3 Door4 Request to exit IN 4 Door5 Request to exit IN 5 Door6 Request to exit IN 6 Door7 Request to exit IN 7 Door8 Request to exit IN 8 Readers Read...

Page 34: ...s The last five DIP switches are used to set the binary code of the access control panel internal network address The default access control panel address is 1 For successful communications the DIP switch must match the address set in the AxTraxNG software Table 4 displays the 32 address settings available ...

Page 35: ...N OFF 8 OFF OFF ON ON ON 9 OFF ON OFF OFF OFF 10 OFF ON OFF OFF ON 11 OFF ON OFF ON OFF 12 OFF ON OFF ON ON 13 OFF ON ON OFF OFF 14 OFF ON ON OFF ON 15 OFF ON ON ON OFF 16 OFF ON ON ON ON 17 ON OFF OFF OFF OFF 18 ON OFF OFF OFF ON 19 ON OFF OFF ON OFF 20 ON OFF OFF ON ON 21 ON OFF ON OFF OFF 22 ON OFF ON OFF ON 23 ON OFF ON ON OFF 24 ON OFF ON ON ON 25 ON ON OFF OFF OFF 26 ON ON OFF OFF ON 27 ON O...

Page 36: ... 425x B Hardware Settings 36 AC 425x B Hardware Installation and User Manual The AC 425x B panel address is defined in the AxTraxNG software The DIP switch and the software must be set to the same address ...

Page 37: ... 232 Serial Network with RS 485 TCP IP Network AC 425IP B model only 6 1 Serial Network Connection The computer serial port controlling the access control panel is set from within the AxTraxNG server The default bitrate is 9600 bps for direct connection to the computer When using an RS 232 connector only one access control panel can be linked to each communication port on the computer Use an RS 48...

Page 38: ...e RS 485 position Using the RS 485 up to 32 access control panels can be linked together and connected to a single communication port on the computer Figure 18 Figure 18 RS 485 Panel Connection to PC Use the RS 485 interface for situations where there are multiple controllers connected The serial port used to control the access control panel is assigned within the AxTraxNG software The AC 425x B s...

Page 39: ... the PC to the last panel in the chain to 4 000 ft 1 219 2 m The first panel is connected directly to the server using an MD 14U converter while the second panel connects to the first panel Additional panels are connected in the same way one after another The server identifies each panel on the RS 485 network by its address At each end of the data line both where the panel connects to the computer...

Page 40: ...ls can be connected on each TCP IP network 6 2 1 LAN and WAN Requirements The devices can be connected to a TCP IP network using any valid network address The AC 425IP B panels connect to the TCP IP network LAN or WAN directly using an onboard network module For each AC 425IP B panel connected on a TCP IP port up to 31 subnetworked panels can be connected via an RS 485 bus which means that one IP ...

Page 41: ...le to connect through the Internet This makes it possible to control multiple access control panels worldwide all from a single computer Before connecting a panel by TCP IP connection for the first time the AxTraxNG software must configure the device Settings then remain stored in non volatile memory on the device see the AxTraxNG Software Manual When using an MD N32 for a single panel either an R...

Page 42: ...d to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does c...

Page 43: ... User Manual 43 B Radio Equipment Directive RED Under our sole responsibility that the following labeled AC 425 Bx AC 425 DIN AC 4215IP Bx and AC 425IP DIN are tested to conform to the EU Radio Equipment Directive RED 2014 53 EU in electrical and electronic equipment ...

Page 44: ...Manual C RoHS Directive Under our sole responsibility that the following labeled AC 425 Bx AC 4215 DIN AC 425IP Bx and AC 425IP DIN are tested to conform to the Restriction of Hazardous Substances RoHS directive 2011 65 EU in electrical and electronic equipment ...

Page 45: ...45 D Limited Warranty The full ROSSLARE Limited Warranty Statement is available in the Quick Links section on the ROSSLARE website at www rosslaresecurity com Rosslare considers any use of this product as agreement to the Warranty Terms even if you do not review them ...

Page 46: ...ecurity com Europe Rosslare Israel Ltd 22 Ha Melacha St P O B 11407 Rosh HaAyin Israel Tel 972 3 938 6838 Fax 972 3 938 6830 support eu rosslaresecurity com Latin America Rosslare Latin America Buenos Aires Argentina Tel 54 11 4001 3104 support la rosslaresecurity com China Rosslare Electronics Shenzhen Ltd Shenzhen China Tel 86 755 8610 6842 Fax 86 755 8610 6101 support cn rosslaresecurity com In...

Reviews: