Rosslare AC-215IP Installation Manual Download Page 11

Technical Specifications 

AC-215IP Hardware Installation Manual 

11 

2.

 

Technical Specifications 

Electrical Characteristics 

Operating Voltage  

12 VDC 1.5 A from PS-14 

Maximum Input Current 

Standby: 120 mA 
Maximum: 370 mA 

General Inputs 

4 supervised high impedance inputs. 
Maximum voltage: 5 VDC 

Relay Outputs 

4 relay outputs 
5 A Relay N.O. and N.C. options 

Reader Ports 

2 reader ports 
Output voltage: 12 VDC 
Max. current: 300 mA 
LED control output D0/D1, tamper input 

Visual Indicators 

11 LEDs 

Audio 

Built in sounder (bell, chime and siren) 

Battery Standby Time 

3 hours (with 12 V, 7 Ah battery) 

 

Communication Characteristics 

RS-232 

Terminal block 

RS-485 

Molex and terminal block 

TCP/IP 

On-board RJ-45 connector 

Speed Options 

9600 bps 
19200 bps 
57600 bps 
115200 bps 

 

Environmental Characteristics 

Operating Temperature Range 

32°F to 120°F (0°C to 49°C) 

Operating Humidity 

0 to 85% (non-condensing) 

 

Dimensions 

Height x Width x Depth 

10.4 x 13.2 x 3.4 in. (264 x 334 x 84.5 mm) 

Weight 

8.38 lbs. (3.81 kg) 

 

Transformer (for AC-215IP only) 

AC Transformer 

120/220 VAC, 16 VAC 2.5 A (40 VA) 

 

Summary of Contents for AC-215IP

Page 1: ...2013 January AC 215IP Single and Double Door Access Control Unit Installation Manual...

Page 2: ...rty rights covering the subject matter in this manual TEXTS IMAGES AND ILLUSTRATIONS INCLUDING THEIR ARRANGEMENT IN THIS DOCUMENT ARE SUBJECT TO THE PROTECTION OF COPYRIGHT LAWS AND OTHER LEGAL RIGHTS...

Page 3: ...Normally Open Input Connection 20 4 1 2 Normally Closed Input Connection 21 4 1 3 Normally Open Supervised Single Resistor Input Connection 21 4 1 4 Normally Open Supervised Double Resistor Input Conn...

Page 4: ...rk Connection 30 6 1 1 RS 232 Connection to the Computer 30 6 1 2 RS 485 Connection to the Computer 31 6 1 3 Daisy Chaining 31 6 2 TCP IP Network Connection 32 6 2 1 LAN and WAN Requirements 32 6 3 Mo...

Page 5: ...n 21 Figure 10 Normally Closed Input Connection 21 Figure 11 Normally Open Supervised Input Single Resistor 22 Figure 12 Normally Open Supervised Input Double Resistor 22 Figure 13 Normally Closed Sup...

Page 6: ...allation Manual List of Tables Table 1 AxTraxNG Capabilities 10 Table 2 Possible Hardware Settings 26 Table 3 DIP Switches and their Functions 27 Table 4 Switch Baud Rates 28 Table 5 Available Panel A...

Page 7: ...guration of the system with the maximum number of functions including future options Therefore not all functions described in this manual may be available in the specific system and or product configu...

Page 8: ...he system can control both single and double door entrances AC 215IP supports up to 30 000 users and uses flash memory to enable easy firmware upgrades For more information on the AxTraxNG system refe...

Page 9: ...tamper switch and LED control buzzer Four inputs selectable as supervised or non supervised Four relay outputs rated 5 A Built in sounder generator for chime bell and siren signals Panel configuratio...

Page 10: ...all aspects of an access panel network Table 1 presents the AxTraxNG software capabilities Table 1 AxTraxNG Capabilities Users capacity 30000 Unauthorized Users 30000 Access groups 30000 Number of pan...

Page 11: ...rol output D0 D1 tamper input Visual Indicators 11 LEDs Audio Built in sounder bell chime and siren Battery Standby Time 3 hours with 12 V 7 Ah battery Communication Characteristics RS 232 Terminal bl...

Page 12: ...ut 12 VDC lead acid battery up to 7 Ah To Relay Outputs Output Voltage 1 12 VDC 0 5 A To Access Control Panel Output Voltage 2 12 VDC 1 5 A PS 14 Power Supply Indication Tamper Output open collector I...

Page 13: ...ry AC 215IP panel controls one or two doors The panels connect together in a network and are controlled by a central server computer running the AxTraxNG software system Figure 2 shows an example setu...

Page 14: ...ts Wiring Non supervised Inputs Figure 3 Inputs Wiring Non supervised Inputs 3 2 Inputs Wiring Supervised Inputs When wiring the AC 215IP for supervised inputs resistors should be placed on the input...

Page 15: ...lation Manual 15 3 3 Outputs Wiring Figure 4 and Figure 5 illustrate wiring for two main types of 12 VDC electrical release mechanisms Other electrical devices can be switched using the voltage free r...

Page 16: ...illustrates wiring between the PS 14 power supply and the AC 215IP It is recommended to add a 12 VDC lead acid backup battery if the main power supply fails If the main output is 12 VDC wire it to the...

Page 17: ...AC 215IP Panel Setup AC 215IP Hardware Installation Manual 17 Figure 6 Wiring Between PS 14 and AC 215IP...

Page 18: ...re Installation Manual 3 5 AC 215IP Access Control Panel Diagram Figure 7 presents a complete view of the AC 215IP control panel s PCB including all connector buttons and LED schematics not to scale F...

Page 19: ...s are supplied with a limited cable The color of the cable cover represents the cable s function When extending the cable distance be careful with the color of the cable cover Refer to the reader spec...

Page 20: ...d inputs Configure each input separately via the AxTraxNG system Non supervised inputs have two states Normal State Abnormal State Supervised inputs have three states Normal State Abnormal State Troub...

Page 21: ...mal State Loop resistance Infinite open circuit Figure 10 Normally Closed Input Connection 4 1 3 Normally Open Supervised Single Resistor Input Connection Connect a resistor of 8 2K in parallel to the...

Page 22: ...2 2K in series to the input switch contacts Connect a resistor of 8 2K parallel to the input switch contacts Normally Open Supervised Input has 3 states Switch Open Normal State Loop resistance 10 4K...

Page 23: ...across input terminals Trouble State Loop resistance 0 short circuit Figure 13 Normally Closed Supervised Input Single Resistor 4 1 6 Normally Closed Supervised Double Resistor Input Connection Conne...

Page 24: ...or Input The Door Monitor Input typically connects to a Normally Closed door sensing micro switch for door status monitoring Using Door Monitor enables many advanced options such as door forced alarm...

Page 25: ...reader Card readers Keypads Dual keypad card readers A keypad is required for any reader mode that requires PIN code entries such as Card or PIN PIN Only or Card and PIN Secured mode When connecting a...

Page 26: ...the possible hardware settings Table 2 Possible Hardware Settings Single Door Outputs Door Lock output OUT 1 General purpose output OUT 1A General purpose output OUT 2 General purpose output OUT 2A I...

Page 27: ...ber of readers for each door one or two readers per door This also affects the number of doors controlled by the panel 4 The access control panel s RS 485 network address 5 6 7 8 Power down the access...

Page 28: ...anel with one reader per each door or a panel with two readers per each door This Dipswitch setting influences the number of doors in the panel The default access control panel setting is for two read...

Page 29: ...f On 7 Off Off On On Off 8 Off Off On On On 9 Off On Off Off Off 10 Off On Off Off On 11 Off On Off On Off 12 Off On Off On On 13 Off On On Off Off 14 Off On On Off On 15 Off On On On Off 16 Off On On...

Page 30: ...e three connection modes Serial Network RS 232 or RS 485 Modem Network TCP IP Network 6 1 Serial Network Connection The computer serial port controlling the access control panel is set from within the...

Page 31: ...s connected The serial port used to control the access control panel is assigned within the AxTraxNG software The access control panel supports the two wire RS 485 interface RS 485 interface enables t...

Page 32: ...cted to a TCP IP network using any valid network address Use a TCP IP connection when a LAN network already exists and the long RS 485 network is not required The following schematic illustrates the c...

Page 33: ...e manual 6 3 1 Hardware Requirements 2 Standard Telephone cables RJ11 plugs in both sides Crossed 9 pin RS 232 cable female jack on both sides Rosslare MD 14 RS 232 to RS 485 converter 2 Rosslare MD N...

Page 34: ...d MD N33 Make sure that the power LED Red is on 2 Connect the MD N33 s RJ11 jack to the telephone wall mount using the telephone cable 3 Connect the MD N33 DB9 female jack to the MD 14 DB9 female jack...

Page 35: ...his warranty Unless otherwise requested by a ROSSLARE representative return of the failed product s is not immediately required If ROSSLARE has not contacted the Customer within a sixty 60 day holding...

Page 36: ...or tampering with the Product if Product disassembled or repaired in such a manner as to adversely affect performance or prevent adequate inspection and testing to verify any warranty claim ROSSLARE...

Page 37: ...pport na rosslaresecurity com Europe Rosslare Israel Ltd Rosh HaAyin Israel Tel 972 3 938 6838 Fax 972 3 938 6830 support eu rosslaresecurity com Latin America Rosslare Latin America Buenos Aires Arge...

Reviews: