![Ross W70 Series Product Information Download Page 3](http://html1.mh-extra.com/html/ross/w70-series/w70-series_product-information_1488846003.webp)
IMPORTANT NOTE:
Please read carefully and thoroughly all of the
CAUTIONS, WARNINGS
on the inside back cover.
C5.3
Online Version
02/19/20
#
Voltage:
W
=24 VDC;
Z
=100-110/50, 100-130/60 VAC/Hz, e.g., W6577A2902
Z
. For other voltages, consult ROSS.
##
Voltage:
Z=100-110/50, 100-130/60 VAC/Hz.
*
Sub-bases and manifold bases ordered separately, refer to page C5.14-C5.18.
**
Valve Response Time –
Response Time (msec) = M + (F • V). This is the average time required to fill a volume V (cubic inches) to 90% of supply
pressure or to exhaust it to 10% of supply pressure. M and F values are shown above.
ANSI
W70 Series
Direct Solenoid Controlled Valves
6.96 (177)
3.12 (79)
2.25 (57)
2.88 (73)
1.97 (50)
8.23 (209)
3.94 (100)
2.60 (66)
3.41 (87)
2.63 (67)
10.0 (254)
2.8 (70)
3.5 (88)
ANSI Size 1
ANSI Size 2.5
ANSI Size 4
1
5 3
4 2
14
5-Way 2-Position Valves, Single Direct Solenoid, Spring Return
ANSI
Size
Port Size
Valve Model
Number
*
Avg.
C
V
Average Response Constants
**
Weight
lb
(kg)
M
F
In-Out
Out-Exh.
1
1/4 - 3/8
W7016B2331
W
#
1.0
20
3.5
4.9
3.5 (1.6)
2.5 3/8 - 1/2
W7016A3331Z
##
2.5
17
1.6
2.7
3.3 (1.5)
4
3/8 - 3/4
W7016C4331Z
##
4.2
–
–
–
4.3 (1.9)
1
5 3
4 2
14
12
5-Way 2-Position Valves, Double Direct Solenoid, Detented
ANSI
Size
Port Size
Valve Model
Number
*
Avg.
C
V
Average Response Constants
**
Weight
lb
(kg)
M
F
In-Out
Out-Exh.
1
1/4 - 3/8 W7016B2332
W
#
1.0
20
3.5
4.9
3.5 (1.6)
2.5 3/8 - 1/2 W7016A3332Z
##
2.5
10
1.3
1.8
3.3 (1.5)
4
3/8 - 3/4 W7016C4332Z
##
4.2
–
–
–
4.3 (1.9)
5-Way 3-Position Valves, Double Direct Solenoid
ANSI
Size
Port Size
Valve Model Number
#*
Avg.
C
V
Average Response Constants
**
Weight
lb (kg)
Power Center
Closed Center
Open Center
M
F
In-Out
Out-Exh.
1
1/8 - 3/8
W7017B2905
W
W7017B2331
W
W7017B2332
W
1.0
20
3.5
4.9
4.5 (2.0)
2.5
3/8 - 1/2
–
W7017A3331
W
W7017A3332
W
1.9
10
1.3
1.8
5.0 (2.3)
4
1/2 - 3/4
–
W7017C4331
W
W7017C4332
W
3.8
–
–
–
5.8 (2.6)
Closed Center
Open Center
Power Center
1
2
3
4
5
12
14
1
2
3
4
5
12
14
1
5 3
4 2
14
12
Double Solenoid
Single Solenoid
9.30 (236)
3.12 (79)
2.25 (57)
2.88 (73)
1.97 (50)
10.75 (273)
3.94 (100)
2.60 (66)
3.41 (87)
2.63 (67)
13.20 (335)
2.80 (70)
3.5 (88)
Double Solenoid
Single Solenoid
Double Solenoid
Single Solenoid
Options: Indicator Light (in Base/Manifold), refer to page C5.17-C5.18. Accessories ordered separately, refer to page C5.19.
C5
Valve Dimensions –
inches (mm)
STANDARD SPECIFICATIONS
(for valves on this page)
:
Construction Design
Spool and Sleeve
Mounting Type
Base
Solenoids
Rated for continuous duty. AC power; DC for ANSI size 1 models only.
Voltage
24 volts DC; 110-120 volts AC, 50/60 Hz
Power Consumption
(each solenoid)
20 watts on DC;
ANSI
Size 1:
140 VA inrush, 30 VA holding on 50 or 60 Hz
ANSI
Size 2.5 & 4:
380 VA inrush, 79 VA holding on 50 or 60 Hz
Temperature
Ambient:
40° to 120°F (4 to 50°C)
Temperature
Media:
40° to 175°F (4° to 80°C)
For other temperature ranges, consult ROSS.
Flow Media
Filtered air
Operating Pressure
Vacuum to 150 psig (10 bar)
Construction Material
Valve Body:
Cast Aluminum
Spool:
Stainless Steel
Seals:
Buna-N
Manual Override
Flush; Rubber, non-locking