Synergy Series Operation Guide (v18)
Memory Functions and More • 8–7
•
(Synergy 4 only) Press
MLE 4
to store just the contents of
MLE 4
in a selected
memory register. To store
MLE 4
plus another MLE, press the desired MLE buttons
simultaneously, e.g.,
MLE 4 + MLE 3 + MLE 2
.
•
(Synergy 2 only) Press
MLE 1 RATE
to change transition rates for MLE 1 effects
(in the
MLE 1 Transition
group). This button is located in the
Global Memory
System
group because the Synergy 2 does
not
have an
MLE Memory Group
.
Changing MLE Auto Transition Rates
instructions.
•
(Synergy 2 only) Press
MLE 2 RATE
to change transition rates for MLE 2
(Program/Preset) effects. Refer to the section “
” on page 5–11 for details.
•
(Synergy 3 only) Press
MLE 3 RATE
to change transition rates for MLE 3
(Program/Preset) effects. Refer to the section “
” on page 5–11 for details.
•
(Synergy 4 only) Press
MLE 4 RATE
to change transition rates for MLE 4
(Program/Preset) effects. Refer to the section “
” on page 5–11 for details.
•
(Synergy 2 only) Press
KEY RATE
to change transition rates for both MLE 1 key
groups (the rate is identical). This button is located in the
Global Memory System
group because the Synergy 2 does
not
have an
MLE Memory Group
. Refer to the
” on page 7–46 for details.
•
(All Switchers) Press
FADE RATE
to change the switcher’s fade-to-black
transition rate. Refer to the section “
for instructions.
•
(All Switchers) Press
DSK RATE
to change the switcher’s downstream key
transition rates. The rate is identical for DSK 1 and DSK 2. Refer to the section
“
Changing DSK Auto Transition Rates
” on page 7–45 for instructions.
5. Remote Section
The
Remote Section
includes buttons for toggling remote control from external devices.
The group is identical for all switchers.
•
Press
EDITOR
to toggle remote control from an external edit controller. The
Editor Interface Option
must be installed. When lit, remote control is enabled (but
local operation can still be performed). When off, the switcher is entirely “local.”
Refer to the section “
Editor Interface
” for details.
•
Press
GPI
to toggle remote control from external GPI sources. The button controls
GPI input pulses — output pulses are not affected. When the button is lit, remote
GPI control is enabled. When the button is off, external GPI control is disabled.
Refer to the section “
GPI Control
” for details.
Note
The
ALL
,
MLE 1
,
MLE 2
,
MLE 3
and
MLE 4
buttons can also be
used with the buttons in the
Recall Section
to reset the entire switcher,
or selected MLEs. Refer to the section “
for details.
MLE
4
MLE1
RATE
MLE2
RATE
MLE3
RATE
MLE4
RATE
KEY
RATE
FADE
RATE
DSK
EDITOR
GPI
Summary of Contents for SYNERGY 4000DR-003
Page 1: ...Ross Video Limited Operation Guide Volume I Software Issue 18...
Page 10: ......
Page 42: ...1 26 Introduction Synergy Series Operation Guide v18...
Page 64: ...2 22 Control Panel Introduction Synergy Series Operation Guide v18...
Page 132: ...4 54 Switcher Basics Synergy Series Operation Guide v18...
Page 242: ...7 68 Keying Synergy Series Operation Guide v18...
Page 280: ...8 38 Memory Functions and More Synergy Series Operation Guide v18...
Page 310: ...GL 4 Glossary of Terms Synergy Series Operation Guide v18...
Page 332: ...IX 22 Index Synergy Series Operation Guide v18...