To Set an Alarm

The alarm notifies users in DashBoard that a power

supply is failing.

1.

Double-click on the 

Panel

 node and click on the

Alarm Enables

 tab.

2.

Select the alarms that you want to enable.

PSU1 Voltage Out of Range

 — alarm if

power supply 1 is out of the safe acceptable

voltage range

PSU2 Voltage Out of Range

 — alarm if

power supply 2 is out of the safe acceptable

voltage range

To Restore Default Settings

All settings, except for the network settings, can be

defaulted back to the factory settings.

1.

Double-click on the 

Panel

 node and click on the

Load/Save

 tab.

2.

Click 

Load Factory Default

.

Note: 

 All setting, except the network settings, are

defaulted.

DIP Switches

The up position for the DIP switch is OFF.

DIP1 DIP2 DIP3 DIP4 Function

OFF OFF

User IP Settings

OFF ON

Force DHCP IP

ON OFF

Force Static IP (192.168.2.10)

ON ON

Force Static IP (10.1.2.10)

OFF

You must enter your DashBoard

password to save changes to this

module in DashBoard.

ON

No password is required.

OFF Default Boot

ON Boot from memory card

Restart and Status LED

Press and hold the 

RESET

 button to restart the unit.

The Status LED changes colors to indicate the status.

Off

 — no power connected

Red

 — Booting

Blinking

 — Upgrading

Green

 — Normal

Setting Up Communications with Acuity

To use SideBoxNet with Acuity

 you must

set up communications between the two. Once

communications are set up you can configure the

particular module that you have installed in the

SideBoxNet. Refer to the documentation that came

with your switcher for information on mapping a

module to a control panel and setting up that module.

To Set Up Communications with Acuity

Note: 

 You cannot have more than one SideShotNet,

SideSlideNet, and SideStick on the same external row. For

example, you cannot have two SideStick modules on the

same row, but you can have a SideShotNet and a SideStick

on the same row.

1.

Press 

HOME

 > 

Setup

 > 

Installation

 > 

Com

Setup

 > 

Type

.

2.

Press 

Type

 and use the 

Com Port

 knob to select

the Remote or PanelNet port that you want to use

to connect to the SideBoxNet.

3.

Use the 

Device

 knob to select 

OGP

.

4.

Press 

Select Device

 and use the 

Device

 knob to

select 

ePCH

.

5.

Press 

Com Type

 and use the 

Type

 knob to select

Network TCP

.

6.

Press 

Com Settings

 and use the 

Client/Server

knob to select 

Client

 and enter the IP address of

the device in the 

Remote IP Address

 field and

5253

 in the 

Remote Port

 field.

7.

Press 

Extra Options

.

Option

Value

Unit ID

Each SideBoxNet must

be assigned to a different

number (

1

-

15

).

4