![Ross RXT175P General Instruction For Installation Use And Maintenance Download Page 7](http://html1.mh-extra.com/html/ross/rxt175p/rxt175p_general-instruction-for-installation-use-and-maintenance_1489068007.webp)
Page 7
RXT175P
THE RATING PLATE
The rating plate is fitted to the front of the welder and displays the
following symbols and information.
30A/15.5V to 145A/21.25
X
15%
60%
100%
Uo = 35V
I
2
145A 73A 56A
U
2
21.25V 17.65V 16.8V
1 ~ 50Hz
U
1
= 230V
I
1 Max
= 25A
IP21S
I
1 eff
=10.2A
RXT175P
AS60974-1
Sn.
Caution! Read operator’s manual
Ground
Single phase transformer - Rectified
1 ~50Hz
Mains supply single phase A.C.
50 Hz
RCM Marking indicating compliance to
relevant Australian standards.
Mig Welding
Outputs direct current. D.C.
x
Duty Cycle
U
2
Rated Welding Voltage
I
1
Rated Input Current
U
0
Rated no load voltage
I
2
Rated Welding Current
IP21S
Protection Class
U
1
Rated Input voltage
%
Percentage of full rated load
...A/...V~...A/...V: Output Range. Minimum and maximum rated welding current and
related load voltage.